Patton electronic user manual Patton Electronics Model 1094A Specifications

Page 14

5.3.3 Using the V.52 (BER) Test Pattern Generator

To use the V.52 BER tests in conjunction with the Remote Digital Loopback tests (or with Local Line Loopback tests), follow these instructions:

1.Locate the “511/511E” toggle switch on the front panel of the 1094A and move it UP. This activates the V.52 BER test mode and transmits a “511” test pattern into the loop. If any errors are present, the local modem’s red “ER” LED will blink sporadically.

2.If the above test indicates no errors are present, move the V.52 toggle switch DOWN, activating the “511/E” test with errors present. If the test is working properly, the local modem's red “ER” LED will glow. A successful “511/E” test will confirm that the link is in place, and that the Model 1094A’s built-in “511” generator and detector are working properly.

NOTE: The above V.52 BER tests can be used independently of the Remote Digital Loopback tests. This requires two opera- tors: one to initiate and monitor the tests at the local Model 1094A, and one to do the same at the remote Model 1094A. In this case, the test pattern sent by each Model 1094A will not be looped back, but will be transmitted down the line to the other Model 1094A. While one operator initiates test, the other moni- tors for errors.

APPENDIX A

PATTON ELECTRONICS MODEL 1094A

SPECIFICATIONS

Transmission Format:

Synchronous

Transmission Line:

Two-Wire unconditioned twisted pair

Clocking:

Internal, external or receive recovered clock

Interface Modules:

EIA RS-232/ITU/T V.24, RS-232/530,

 

ITU/T V.35 and ITU/T X.21

Line Rates:

144, 272, 400, 528, 784, 1040, and 1168

 

kbps

DTE Rates:

64, 128, 192, 256, 320, 384,448, 512, 576,

 

640, 704, 768, 832, 896, 960, 1024, 1088,

 

and 1152 kbps

Diagnostics:

V.52 compliant bit error rate pattern

 

(511/511E pattern) generator and detector

 

with error injection mode; Local Line

 

Loopback and Remote Digital Loopback,

 

activated by front panel switch or via serial

 

interface

LED Status Indicators:

TD, RD, CTS, CD, DTR, NS(no signal), ER

 

(error) and TM (test mode)

Connectors:

RJ-45 on line side; DB-25 female, M/34

 

female or DB-15 female on serial interface

 

side, depending upon which interface

 

module is installed.

Power:

100-253 VAC, 50-60 Hz (universal input);

 

48 VDC (option). 10 watts.

Temperature Range:

32-122°F (0° -50°C)

Altitude:

0-15,000 feet

Humidity:

5 to 95% non-condensing

Dimensions:

7.3” x 6.6” x 1.62” (185mm x 168mm x

 

41mm)

Weight:

2.01 lbs. (1.0kg)

25

26

Image 14
Contents User NUA L CE Notice SectionRadio and TV Interference Tel Email support@patton.com ServiceFeatures DescriptionConfiguration DIP Switch Set S2 Configuring the Hardware DIP SwitchesConfiguration DIP Switch Set S1 Reserved Switches S2 Summary TableCO/CP S3 Summary TableConnecting the Twisted Pair Interface Switch S3-7 Reset Software DefaultsSwitch S3-8 Transmit Data TD Sampling Point Connecting the Serial Port Connecting to a DC Power Source Configuring the X.21 QuikConnect ModuleConnecting Power TD & RD POWER-UPLED Status Monitors CTSPattern Gen/Det Symbol IndicatorsFramer Loop ControlLocal Loop Loops and PatternsLocal Loop There are two different modes of operation for a With 511/511EAfter the 511/511E pattern times out, the ER led 511/511E Remote DigitalLoop with Patton Electronics Model 1094A Specifications Patton Electronics Model # Description Patton Electronics Model 1094A Interface PIN AssignmentsDTE /DCE Configuration Pin # SignalPatton Electronics Model 1094A Transmission Distances Transmission Distance Patton NetLink Hdsl Model 1094A