Patton electronic manual Model 3034/3038 installation

Page 21

Chapter 3

Model 3034/3038 installation

 

Chapter contents

 

 

Planning the installation

22

Site log

22

Network information

22

Network Diagram

22

IP related information

23

Software tools

23

Power source

23

Location and mounting requirements

23

Installing the Model 3034/3038

23

Placing the Model 3034/3038

23

Installing cables

24

Connecting the RS-232 ports

24

Connecting the 10/100Base-T Ethernet LAN and WAN cables

25

Connecting the Composite port

25

Models with a V.35 port (3034/C and 3038/C)

25

Models with an X.21 port (3034/D and 3038/D)

25

Models with a T1/E1 port and BNC Connectors (3034/K and 3038/K)

25

Connecting the power supply

26

Internal AC Power Supply

27

External AC Power Supply

27

External DC Power Supply

28

21

Image 21
Contents Models 3034/3038 Mailsupport@patton.com Summary Table of Contents Table of Contents Sync Serial Configuration Cabling List of Figures List of Tables About this guide AudienceStructure Impaired functioning PrecautionsGeneral observations Safety when working with electricityGeneral conventions Typographical conventions used in this documentGeneral information Chapter contentsModel Model 3034/3038 OverviewModel 3034/3038 Features Features and BenefitsModel 3034/3038 rear panel Rear and Front PanelsModels V.35 DTE interface on a DB-25 female connector LED Model 3034/3038 front panelApplications overview Typical application for Model 3034/3038 Typical Model 3034/3038 ApplicationModel 3034/3038 installation Create a network diagram see section Network information on Planning the installationNetwork Diagram Site logInstalling the Model 3034/3038 Connect the cables in the following order Installing cablesModels with an X.21 port 3034/D and 3038/D Models with a V.35 port 3034/C and 3038/CConnecting the power supply Connecting to the dual BNC connectorsExternal AC Power Supply Internal AC Power SupplyTo Power Supply Jack External DC Power SupplyInitial configuration Connecting the Model 3034/3038 to your PC Connecting and logging in via the Ethernet portIntroduction Connecting and logging in via the Console port Factory-default IP settingsConfiguring the desired IP address Login Connecting the Model 3034/3038 to the networkChanging the IP address Saving the IP addressRS-232 port configuration Configuration Overview OverviewPort Configuration Web Management Interface WMIExample show cont terminal command Command Line Interface CLISync Serial Configuration See the section Web Management Interface WMI on Example show controller sync-serial command Contacting Patton for assistance Contact information Warranty coveragePatton support headquarters in the USA Fax +1 253Patton Electronics Company RMA numbersAppendix a Compliance information Compliance SafetyRadio and TV Interference FCC Part 68 Acta StatementIndustry Canada Notice CE Declaration of ConformityAuthorized European Representative Appendix B Specifications RS-232 Ports CommandsComposite Ports Ethernet PortsTemperature 0-40C IP ServicesIP Connectivity Operating EnvironmentAppendix C Cabling DB-9 serial port ConsoleEthernet Appendix D Port pin-outs EIA-561 RJ-45 8-pin port Console port35 DB-25 connector 21 DB-15 connector T1/E1 RS-232 Appendix E End user license agreement End User License Agreement Other licenses Termination

3034/3038 specifications

The Patton Electronic 3034/3038 is a robust communication platform designed to facilitate connectivity in various networking environments. Tailored for both enterprise and industrial applications, the 3034/3038 is known for its efficiency, reliability, and advanced features which enhance network performance.

One of the standout attributes of the 3034/3038 is its support for multiple interfaces, making it versatile for a wide range of installations. It offers options such as T1, E1, and V.35, ensuring compatibility with legacy systems while providing support for modern networking demands. This adaptability allows businesses to leverage existing infrastructure while smoothly transitioning to newer technologies.

The Patton 3034/3038 also incorporates superior signal regeneration capabilities. With built-in error correction, jitter buffering, and signal conditioning, these devices effectively maintain data integrity over long-distance transmissions. This can prove crucial in environments where reliable communication is necessary, such as in financial services or emergency response systems.

Another key feature is its ease of management. The device supports SNMP (Simple Network Management Protocol), enabling IT administrators to monitor and manage network performance seamlessly. The user-friendly interface allows for remote diagnostics and configuration, minimizing downtime and reducing the need for on-site visits.

In terms of security, the 3034/3038 provides robust features to ensure data privacy and integrity. These include support for encryption protocols, ensuring that sensitive information remains protected during transmission. This aspect is vital in sectors handling confidential data, such as healthcare and banking.

The 3034/3038 is designed for durability and reliability. Built to withstand harsh environmental conditions, it can operate effectively in industrial settings. The device is also equipped with power redundancy features, which enhance its reliability, ensuring continuous operation and minimizing the risk of interruptions.

Overall, the Patton Electronic 3034/3038 is a powerful solution for businesses looking to enhance their networking capabilities. With its range of features, robust technology, and focus on reliability and security, it serves as an essential tool in creating efficient, high-performance communication networks. Whether for modern enterprises or industrial applications, this device proves to be a valuable asset capable of meeting diverse connectivity needs.