Patton electronic 3034/3038 manual Command Line Interface CLI, Example show cont terminal command

Page 36

Model 3034/3038 Getting Started Guide

5 • RS-232 port configuration

 

 

Command Line Interface (CLI)

The following commands are used to configure the terminal interfaces:

Table 7. Stat Mux- CLI Commands

 

 

Step

Explanation

 

 

configure controller terminal

Enter the serial controller configuration mode.

<0-7>

 

 

 

clear

Reset the statistics shown in the show command.

 

 

data {5,6,7,8}

Set the data bits of the terminal interface.

 

 

flow {none,rtscts,xonxoff}

Set the flow control of the terminal interface.

 

 

mode {none,master,slave}

Set the mode of the terminal interface. An interface can only

 

operate in one mode at a time.

 

 

mode master <A.B.C.D>

Enable master mode, configure remote IP address, and config-

[<0-40000>]

ure optional port number. If no port number is specified, the

[allow-remote-control]

default port value is 30000 plus the number of the terminal

 

interface (ie 30001 for terminal interface 1). Enable remote

 

control of the port.

 

 

mode slave [<0-40000>]

Enable slave mode and configure optional port number.

 

 

parity {even, mark, none, odd,

Set the parity of the terminal interface.

space}

 

 

 

show

Display the configuration and statistics for this interface.

 

 

[no] shutdown

Enables or disables the terminal interface.

 

 

speed <50-230400>

Set the baud rate of the terminal interface.

 

 

stop-bits {2,1.5, 1}

Set the baud rate of the terminal interface.

 

 

show cont terminal

Show configuration of all terminal interfaces

 

 

Example – show cont terminal command:

PortSpeedParity

Flow

Data Size

Stop Bits

0

9600 none

none

cs8

one

1

9600 none

none

cs8

one

2

19200 even

none

cs8

one

3

9600 none

none

cs8

one

4

19200 none

none

cs8

one

5

19200 none

none

cs8

one

6

9600 none

none

cs8

one

7

9600 none

none

cs8

one

Command Line Interface (CLI)

36

Image 36
Contents Models 3034/3038 Mailsupport@patton.com Summary Table of Contents Table of Contents Sync Serial Configuration Cabling List of Figures List of Tables About this guide AudienceStructure Precautions Impaired functioningSafety when working with electricity General observationsTypographical conventions used in this document General conventionsChapter contents General informationModel 3034/3038 Overview ModelFeatures and Benefits Model 3034/3038 FeaturesRear and Front Panels Model 3034/3038 rear panelModels V.35 DTE interface on a DB-25 female connector Model 3034/3038 front panel LEDApplications overview Typical Model 3034/3038 Application Typical application for Model 3034/3038Model 3034/3038 installation Planning the installation Create a network diagram see section Network information onNetwork Diagram Site logInstalling the Model 3034/3038 Installing cables Connect the cables in the following orderModels with a V.35 port 3034/C and 3038/C Models with an X.21 port 3034/D and 3038/DConnecting to the dual BNC connectors Connecting the power supplyInternal AC Power Supply External AC Power SupplyExternal DC Power Supply To Power Supply JackInitial configuration Connecting the Model 3034/3038 to your PC Connecting and logging in via the Ethernet portIntroduction Connecting and logging in via the Console port Factory-default IP settingsConfiguring the desired IP address Connecting the Model 3034/3038 to the network LoginChanging the IP address Saving the IP addressRS-232 port configuration Overview Configuration OverviewWeb Management Interface WMI Port ConfigurationCommand Line Interface CLI Example show cont terminal commandSync Serial Configuration See the section Web Management Interface WMI on Example show controller sync-serial command Contacting Patton for assistance Warranty coverage Contact informationPatton support headquarters in the USA Fax +1 253RMA numbers Patton Electronics CompanyAppendix a Compliance information Safety ComplianceRadio and TV Interference FCC Part 68 Acta StatementIndustry Canada Notice CE Declaration of ConformityAuthorized European Representative Appendix B Specifications Commands RS-232 PortsComposite Ports Ethernet PortsIP Services Temperature 0-40CIP Connectivity Operating EnvironmentAppendix C Cabling Console DB-9 serial portEthernet Appendix D Port pin-outs Console port EIA-561 RJ-45 8-pin port35 DB-25 connector 21 DB-15 connector T1/E1 RS-232 Appendix E End user license agreement End User License Agreement Termination Other licenses

3034/3038 specifications

The Patton Electronic 3034/3038 is a robust communication platform designed to facilitate connectivity in various networking environments. Tailored for both enterprise and industrial applications, the 3034/3038 is known for its efficiency, reliability, and advanced features which enhance network performance.

One of the standout attributes of the 3034/3038 is its support for multiple interfaces, making it versatile for a wide range of installations. It offers options such as T1, E1, and V.35, ensuring compatibility with legacy systems while providing support for modern networking demands. This adaptability allows businesses to leverage existing infrastructure while smoothly transitioning to newer technologies.

The Patton 3034/3038 also incorporates superior signal regeneration capabilities. With built-in error correction, jitter buffering, and signal conditioning, these devices effectively maintain data integrity over long-distance transmissions. This can prove crucial in environments where reliable communication is necessary, such as in financial services or emergency response systems.

Another key feature is its ease of management. The device supports SNMP (Simple Network Management Protocol), enabling IT administrators to monitor and manage network performance seamlessly. The user-friendly interface allows for remote diagnostics and configuration, minimizing downtime and reducing the need for on-site visits.

In terms of security, the 3034/3038 provides robust features to ensure data privacy and integrity. These include support for encryption protocols, ensuring that sensitive information remains protected during transmission. This aspect is vital in sectors handling confidential data, such as healthcare and banking.

The 3034/3038 is designed for durability and reliability. Built to withstand harsh environmental conditions, it can operate effectively in industrial settings. The device is also equipped with power redundancy features, which enhance its reliability, ensuring continuous operation and minimizing the risk of interruptions.

Overall, the Patton Electronic 3034/3038 is a powerful solution for businesses looking to enhance their networking capabilities. With its range of features, robust technology, and focus on reliability and security, it serves as an essential tool in creating efficient, high-performance communication networks. Whether for modern enterprises or industrial applications, this device proves to be a valuable asset capable of meeting diverse connectivity needs.