Patton electronic 3034/3038 manual Web Management Interface WMI, Port Configuration

Page 35

Model 3034/3038 Getting Started Guide

5 • RS-232 port configuration

 

 

Web Management Interface (WMI)

To access the statistical multiplexer main page, click on Interface Configuration > Terminal from the menu on the left of the screen.

Figure 13. Terminal Configuration

The Terminal Configuration main page displays the list of terminal ports and the current state of the ports. 3034 Models have four terminal ports and 3038 models have 8 terminal ports.

Port Configuration

To configure a terminal port:

1.Click on the number of the port you would like to configure in the Port column on the Terminal Config- uration main page.

2.The Terminal Port Status page displays. Click on the Configuration tab at the top of the page.

3.Check the Enabled box to turn on the terminal port.

4.Set the following fields:

Datasize: Set the data bits of the terminal port. Select an option from the range 5–8.

Flow Control: Set the flow control of the terminal port. Select None, RTS/CTS, or XON/XOFF.

Parity: Set the parity of the terminal port. Select Even, Mark, None, Odd, or Space.

Speed: Set the baud rate for the terminal port. Select an option from the range 50–230400.

Stop Bits:Set the baud rate for the terminal port. Select 1 or 2.

Mode: Set the mode for the terminal port configuration. Select master or slave.

Remote IP address: Set the IP address of the slave 3034/3038.

Port Number: Set the Port Number to use (or <cr> for default).

Allow-remote-control:Set this to allow remote control of the port.

5.Click Update to save your settings.

Web Management Interface (WMI)

35

Image 35
Contents Models 3034/3038 Mailsupport@patton.com Summary Table of Contents Table of Contents Sync Serial Configuration Cabling List of Figures List of Tables Structure About this guideAudience Impaired functioning PrecautionsGeneral observations Safety when working with electricityGeneral conventions Typographical conventions used in this documentGeneral information Chapter contentsModel Model 3034/3038 OverviewModel 3034/3038 Features Features and BenefitsModel 3034/3038 rear panel Rear and Front PanelsModels V.35 DTE interface on a DB-25 female connector LED Model 3034/3038 front panelApplications overview Typical application for Model 3034/3038 Typical Model 3034/3038 ApplicationModel 3034/3038 installation Site log Planning the installationCreate a network diagram see section Network information on Network DiagramInstalling the Model 3034/3038 Connect the cables in the following order Installing cablesModels with an X.21 port 3034/D and 3038/D Models with a V.35 port 3034/C and 3038/CConnecting the power supply Connecting to the dual BNC connectorsExternal AC Power Supply Internal AC Power SupplyTo Power Supply Jack External DC Power SupplyInitial configuration Introduction Connecting the Model 3034/3038 to your PCConnecting and logging in via the Ethernet port Configuring the desired IP address Connecting and logging in via the Console portFactory-default IP settings Saving the IP address Connecting the Model 3034/3038 to the networkLogin Changing the IP addressRS-232 port configuration Configuration Overview OverviewPort Configuration Web Management Interface WMIExample show cont terminal command Command Line Interface CLISync Serial Configuration See the section Web Management Interface WMI on Example show controller sync-serial command Contacting Patton for assistance Fax +1 253 Warranty coverageContact information Patton support headquarters in the USAPatton Electronics Company RMA numbersAppendix a Compliance information FCC Part 68 Acta Statement SafetyCompliance Radio and TV InterferenceAuthorized European Representative Industry Canada NoticeCE Declaration of Conformity Appendix B Specifications Ethernet Ports CommandsRS-232 Ports Composite PortsOperating Environment IP ServicesTemperature 0-40C IP ConnectivityAppendix C Cabling DB-9 serial port ConsoleEthernet Appendix D Port pin-outs EIA-561 RJ-45 8-pin port Console port35 DB-25 connector 21 DB-15 connector T1/E1 RS-232 Appendix E End user license agreement End User License Agreement Other licenses Termination

3034/3038 specifications

The Patton Electronic 3034/3038 is a robust communication platform designed to facilitate connectivity in various networking environments. Tailored for both enterprise and industrial applications, the 3034/3038 is known for its efficiency, reliability, and advanced features which enhance network performance.

One of the standout attributes of the 3034/3038 is its support for multiple interfaces, making it versatile for a wide range of installations. It offers options such as T1, E1, and V.35, ensuring compatibility with legacy systems while providing support for modern networking demands. This adaptability allows businesses to leverage existing infrastructure while smoothly transitioning to newer technologies.

The Patton 3034/3038 also incorporates superior signal regeneration capabilities. With built-in error correction, jitter buffering, and signal conditioning, these devices effectively maintain data integrity over long-distance transmissions. This can prove crucial in environments where reliable communication is necessary, such as in financial services or emergency response systems.

Another key feature is its ease of management. The device supports SNMP (Simple Network Management Protocol), enabling IT administrators to monitor and manage network performance seamlessly. The user-friendly interface allows for remote diagnostics and configuration, minimizing downtime and reducing the need for on-site visits.

In terms of security, the 3034/3038 provides robust features to ensure data privacy and integrity. These include support for encryption protocols, ensuring that sensitive information remains protected during transmission. This aspect is vital in sectors handling confidential data, such as healthcare and banking.

The 3034/3038 is designed for durability and reliability. Built to withstand harsh environmental conditions, it can operate effectively in industrial settings. The device is also equipped with power redundancy features, which enhance its reliability, ensuring continuous operation and minimizing the risk of interruptions.

Overall, the Patton Electronic 3034/3038 is a powerful solution for businesses looking to enhance their networking capabilities. With its range of features, robust technology, and focus on reliability and security, it serves as an essential tool in creating efficient, high-performance communication networks. Whether for modern enterprises or industrial applications, this device proves to be a valuable asset capable of meeting diverse connectivity needs.