Patton electronic 1058 user manual Connecting the TWISTED-PAIR Line Interface

Page 10

3.3 CONNECTING THE TWISTED-PAIR LINE INTERFACE

The Model 1058 supports communication between two peer Ethernet LAN sites over a distance of up to 4,652 ft (1,418 m) over 24 AWG (0.5 mm) twisted-pair wire.

Note Actual distance and link performance may vary depending on the environment and type/gauge of wire used.

Follow the steps below to connect the Model 1058 VDSL Interfaces.

Note The Model 1058 units work in pairs. One of the units must be a Model 1058/CO (Central Office), and the other unit must be a Model 1058/CP (Customer Premise). It does not matter which end is the 1058/CO and which is the 1058/CP. The link is always initiated by the 1058/CP. As long as the 1058/CO is powered on, the 1058/CP can establish a link by being powered on or by hav- ing its power reset.

1.To function properly, the two Model 1058's must be connected together using twisted-pair, unconditioned, dry, metal wire, between 19 (0.9mm) and 26 AWG (0.4mm). Leased circuits that run through signal equalization equipment are not acceptable.

2.The Model 1058 is equipped with two interface jacks that can be used on the VDSL interface, an RJ-45 or a terminal block. These VDSL interfaces are a two-wire interface. Observe the signal/pin relation- ships on the Model 1058's VDSL interface jacks.

The RJ-45 connector on the Model 1058's twisted pair interface is polar- ity insensitive and is wired for a two-wire interface. The signal/pin rela- tionship is shown in Figure 4.

 

1 (no connection)

1

2 (no connection)

23 (no connection)

4

4

(2-Wire RING)

 

 

5

5

(2-Wire TIP)

6

6 (no connection)

7

7 (no connection)

8

8 (no connection)

Figure 4. Model 1058 (RJ-45) twisted pair line interface.

The terminal block connector on the Model 1058's twisted pair interface is polarity insensitive and is wired for a two-wire interface. The signal/pin relationships is shown in Figure 5.

10

Image 10
Contents User Manual Specifications Warranty InformationInstallation General InformationRadio and TV Interference Warranty InformationCE Notice Page Industry Canada Notice Service Tel +1 301 Email support@patton.comGeneral Information FeaturesDescription Typical application Rack Card Installation InstallationStandalone Unit Installation 1058DVVlink 1058DVRC 1058DRCConnecting the TWISTED-PAIR Line Interface Model 1058 RJ-45 twisted pair line interfaceConnecting the 10/100BASE-T Ethernet Interface Connecting the 10/100Base-T Ethernet Port to a Hub1058 10/100Base-T Port 10/100Base-T Hub RJ-45 Pin No Connecting the 10/100Base-T Ethernet Port to a PC DTEConnecting the POTS/ISDN Line 1058 10/100Base-T Port 10/100Base-T DTE RJ-45 Pin NoConnecting Power Model 1058DV RJ-45 POTS/ISDN interfaceOperation Power UPFront Panel LED Status Monitors LED DescriptionTemperature Range LED Status IndicatorsPower Supply DimensionsAppendix B Patton Model # DescriptionPage Vdsl Interface Appendix C10/100BASE-T Interface POTS/ISDN Interface