4.2 CONFIGURING DIP SWITCH S1

DIP switch S1 is where you configure the CopperLINK line. The following tables describe the configuration for the 2173.

Table 1: 2173 Firmware Configuration

 

S1-1

S1-2

S1-3

 

S1-4

Position

 

 

 

 

 

Master/

Mode

 

Rate

 

 

 

Slave

 

 

 

 

 

 

 

 

 

 

 

 

ON

Slave

Fast

 

 

 

 

(CPE)

 

4/1, 100/70, 50/50, 70/70

 

 

 

 

 

 

 

OFF

Master

Interleave

Rate Control

 

(CO)

 

(See table below).

 

 

 

 

 

 

S1-2: Impulse Noise Protection

Fast Mode: Direct data transmission with latency less than 1ms

Interleave Mode: Provides data transmission protection for up to 250 ms impulse noise with latency less than 6 ms

S1-3

S1-4

Rate

 

 

 

OFF

OFF

4/1

ON

OFF

100/70

 

 

 

OFF

ON

50/50

 

 

 

ON

ON

70/70

 

 

 

5.0 OPERATION

Once the Model 2173s are properly installed, they should operate trans- parently. No user settings required. This section describes reading the LED status monitors.

5.1 POWER UP

Before applying power to the Model 2173, please review section 3.3, “Connecting Power” on page 12 to verify that the unit is connected to the appropriate power source.

14

Image 14
Contents User Manual Contents Distance Chart, Based on 24 AWG 0.5 MM Radio and TV Interference FCC Part Warranty InformationRegulatory Information Authorized European Representative ServiceCE Declaration of Conformity Safety When Working with Electricity Page Description FeaturesGeneral Information Installation Typical applicationConnecting the TWISTED-PAIR Line Interface Model Connecting the 10/100BASE-T Ethernet Interface Model 2173 RJ-45 twisted pair line interfaceConfiguring the Hardware DIP Switches Connecting PowerConfiguration Front CPE Configuring DIP Switch S1Power UP OFFFront Panel LED Status Monitors LEDTemperature Range LED Status IndicatorsPower Supply DimensionsAppendix B Base ModelsCopperlink Interface Appendix C10/100BASE-T Interface Appendix D Copyright Patton Electronics Company All Rights Reserved