Patton electronic 3125 manual Operation and shutdown

Page 4

Contents

Model 3125 RAS Getting Started Guide

 

 

Installing the 3125TM Transition Module

27

Installing the 3125RC Resource Card

30

Cable installation

31

Connecting the Ethernet ports

31

Connecting the 10/100Base-T Ethernet port to an Ethernet switch or hub

32

Connecting the 10/100Base-T Ethernet port to an Ethernet-capable workstation

32

Connecting the EIA-561RS-232 configuration port

32

Connecting to the T1/E1/PRI WAN ports

33

Completing the hardware installation

33

3 Configuring the RAS for operation

35

Introduction

36

Configuration prerequisites

36

Preparing the RAS for configuration

36

Configuring the RAS with a Web browser

40

Opening the RAS Web Administration Pages

40

Home page overview

42

Configuring simple authentication

44

No Validation

44

A Static User

45

Configuring dial-in user information

46

Configuring the default gateway

48

Configuring line settings and signaling for E1

49

Configuring the line settings

50

Setting the line signaling for an E1/PRI (ISDN) line

51

Setting the line signaling for an E1/R2 line

51

Channel assignment

53

Configuring line settings and signaling for T1

53

Configuring the line settings

53

Setting the line signaling for an ISDN/PRI line

54

Setting the line signaling for a robbed-bit T1 line

54

Channel assignment

55

Saving your configuration

55

Completing the installation

57

4 Operation and shutdown

59

Introduction

60

Activating the RAS

60

De-activating the RAS

60

5 Contacting Patton for assistance

63

Introduction

64

Contact information

64

Warranty Service and Returned Merchandise Authorizations (RMAs)

64

Warranty coverage

64

Out-of-warranty service

64

4

Image 4
Contents Remote Access Server RAS Patton Electronics Company, Inc Contents Operation and shutdown Contents Contents Model 3125 RAS Getting Started Guide Industry Canada Notice Radio and TV InterferenceFCC Information Facility Service Network Interface Code Connection FCC Part 68 Compliance StatementService CE NoticeCompliance Information Model 3125 RAS Getting Started Guide Audience StructureTypographical conventions used in this document PrecautionsGeneral conventions Mouse conventions About this guide Model 3125 RAS Getting Started Guide Chapter contents IntroductionModel 3125 Remote Access Server overview Patton 2U, 4U, and 6U cPCI platforms Hardware overview WANSignaling Power systemTemperature ModemsPhysical dimensions RC physical dimensionsManagement services SecurityLED display RC status LEDsApprovals Software overview Software overviewHardware installation Unpacking the Model 3125 RAS IntroductionMaterials and Tools Required Model 3125 installation Installing the 3125TM Transition ModuleReleasing a injection/ejection handle RC and 3125TM installation diagram Installing the 3125RC Resource Card Securing the captive fastenersCable installation Connecting the Ethernet portsConnecting the EIA-561 RS-232 configuration port Straight-through RJ-45-to-RJ-45 Ethernet cable diagramCompleting the hardware installation Connecting to the T1/E1/PRI WAN portsCompleting the hardware installation Configuring the RAS for operation Configuration prerequisites Preparing the RAS for configurationConfigure the COM port settings as shown in figure COM properties Login window Opening the RAS Web Administration Pages Configuring the RAS with a Web browserHome Home page overview Home page window panesImmediate Actions buttons Configuring simple authentication No ValidationAuthentication Configuration window Static UserConfiguring dial-in user information Static User Identification windowClick on Modify. The Modify Dial-In window appears see figure Configuring the default gateway Modify Dial-In window, Domain Name Server sectionConfiguring line settings and signaling for E1 T1/E1 Link Activity windowConfiguring the line settings Pinout for loopback to test WAN portSetting the line signaling for an E1/PRI Isdn line Setting the line signaling for an E1/R2 lineMFR Version 2 Modify window Configuring line settings and signaling for T1 Channel assignmentSetting the line signaling for an ISDN/PRI line Setting the line signaling for a robbed-bit T1 lineSaving your configuration Import/Export main window Completing the installation Completing the installation Operation and shutdown Activating the RAS De-activating the RASOperation and shutdown De-activating the RAS Contacting Patton for assistance Warranty coverage Out-of-warranty serviceContact information Returns for creditRMA numbers Return for credit policyShipping instructions

3125 specifications

The Patton Electronics 3125 is a versatile, high-performance device designed for a variety of communication applications. Known for its durability and reliability, this product has made a name for itself in the realm of network connectivity and data communication.

One of the standout features of the 3125 is its support for both T1 and E1 serial data connections. This flexibility allows users to adapt the device to different network environments, making it suitable for various applications ranging from remote access to integrating legacy systems with modern networks. The device supports frame relay and PPP protocols, which are critical for ensuring efficient data transfer across networks.

The Patton 3125 is equipped with advanced technologies that enhance its functionality. For instance, it incorporates an intelligent line monitoring feature, which helps identify and troubleshoot line faults automatically. This capability can minimize downtime, offering users a more reliable communication experience and reducing the need for on-site maintenance.

Another significant characteristic of the 3125 is its built-in network interface card (NIC) support, which allows seamless integration with IP networks. This feature is particularly valuable for businesses looking to modernize their infrastructure without completely overhauling existing systems. Furthermore, the device supports various signaling protocols, including CAS, NI1, and NI2, which facilitates compatibility with different telecom services.

Additionally, the Patton 3125 comes equipped with a user-friendly web-based interface, making configuration and management straightforward. This feature is particularly beneficial for network administrators, allowing them to monitor performance and adjust settings remotely. The device also supports SNMP for enhanced network management capabilities, further streamlining operational efficiency.

In terms of physical characteristics, the Patton 3125 is built to withstand challenging environments. Its robust casing ensures durability, and it features various mounting options for easy installation in different settings, whether in a data center or an office environment.

Overall, the Patton Electronics 3125 stands out for its combination of flexibility, advanced technology, and ease of use, making it a valuable asset for organizations seeking reliable communication solutions. Whether connecting legacy systems or enabling high-speed data transfer, the 3125 meets the demanding needs of today’s network landscape.