Patton electronic 3125 manual Radio and TV Interference, Industry Canada Notice, FCC Information

Page 7

Compliance Information

Radio and TV Interference

The Model 3125 Series generates and uses radio frequency energy, and if not installed and used properly—that is, in strict accordance with the manufacturer's instructions—may cause interference to radio and television reception. The Model 3125 Series has been tested and found to comply with the limits for a Class A comput- ing device in accordance with the specifications in Subpart B of Part 15 of FCC rules, which are designed to provide reasonable protection from such interference in a commercial installation. However, there is no guar- antee that interference will not occur in a particular installation. If the Model 3125 Series causes interference to radio or television reception, which can be determined by disconnecting the cables, try to correct the interfer- ence by one or more of the following measures: moving the computing equipment away from the receiver, re- orienting the receiving antenna, and/or plugging the receiving equipment into a different AC outlet (such that the computing equipment and receiver are on different branches).

Industry Canada Notice

The Canadian Department of Communications label identifies certified equipment. This certification means that the equipment meets certain telecommunications network protective, operational and safety require- ments. The Department does not guarantee the equipment will operate to the user's satisfaction. Before install- ing this equipment, users should ensure that it is permissible to be connected to the facilities of the local telecommunications company. The equipment must also be installed using an acceptable method of connec- tion. In some cases, the company’s inside wiring associated with a single line individual service may be extended by means of a certified connector assembly (telephone extension cord). The customer should be aware that compliance with the above condition may not prevent degradation of service in some situations. Repairs to some certified equipment should be made by an authorized maintenance facility designated by the supplier. Any repairs or alterations made by the user to this equipment, or equipment malfunctions, may give the telecommunications company cause to request the user to disconnect the equipment. Users should ensure for their own protection that the ground connections of the power utility, telephone lines and internal metallic water pipe system, are connected together. This protection may be particularly important in rural areas.

Users should not attempt to establish or modify ground connections themselves, instead they should contact the appropriate electric inspection authority or electrician.

FCC Information

The Model 3125 Series has been tested with the specifications in Part 68 of the FCC rules. Your telephone company may make changes in its facilities, equipment, operations or procedures that could affect the proper operation of the Model 3125. If this happens, the telephone company should give you advance notice to pre- vent the interruption of your service. The telephone company may decide to temporarily discontinue your ser- vice if they believe your Model 3125 Series may cause harm to the telephone network. Whenever possible, they will contact you in advance. If you elect to do so, you have the right to file a complaint with the FCC. If you have any trouble operating the Model 3125, please contact Patton Electronics Technical Support at +1 301- 975-1000. The telephone company may ask you to disconnect the equipment from the telephone network until the problem has been corrected or until you are certain that the Model 3125 Series is not malfunctioning.

7

Image 7
Contents Remote Access Server RAS Patton Electronics Company, Inc Contents Operation and shutdown Contents Contents Model 3125 RAS Getting Started Guide Industry Canada Notice Radio and TV InterferenceFCC Information FCC Part 68 Compliance Statement Facility Service Network Interface Code ConnectionCE Notice ServiceCompliance Information Model 3125 RAS Getting Started Guide Structure AudienceTypographical conventions used in this document PrecautionsGeneral conventions Mouse conventions About this guide Model 3125 RAS Getting Started Guide Introduction Chapter contentsModel 3125 Remote Access Server overview Patton 2U, 4U, and 6U cPCI platforms WAN Hardware overviewModems SignalingPower system TemperatureRC physical dimensions Physical dimensionsSecurity Management servicesRC status LEDs LED displayApprovals Software overview Software overviewHardware installation Unpacking the Model 3125 RAS IntroductionMaterials and Tools Required Installing the 3125TM Transition Module Model 3125 installationReleasing a injection/ejection handle RC and 3125TM installation diagram Securing the captive fasteners Installing the 3125RC Resource CardConnecting the Ethernet ports Cable installationStraight-through RJ-45-to-RJ-45 Ethernet cable diagram Connecting the EIA-561 RS-232 configuration portConnecting to the T1/E1/PRI WAN ports Completing the hardware installationCompleting the hardware installation Configuring the RAS for operation Preparing the RAS for configuration Configuration prerequisitesConfigure the COM port settings as shown in figure COM properties Login window Configuring the RAS with a Web browser Opening the RAS Web Administration PagesHome Home page window panes Home page overviewImmediate Actions buttons No Validation Configuring simple authenticationStatic User Authentication Configuration windowStatic User Identification window Configuring dial-in user informationClick on Modify. The Modify Dial-In window appears see figure Modify Dial-In window, Domain Name Server section Configuring the default gatewayT1/E1 Link Activity window Configuring line settings and signaling for E1Pinout for loopback to test WAN port Configuring the line settingsSetting the line signaling for an E1/R2 line Setting the line signaling for an E1/PRI Isdn lineMFR Version 2 Modify window Channel assignment Configuring line settings and signaling for T1Setting the line signaling for a robbed-bit T1 line Setting the line signaling for an ISDN/PRI lineSaving your configuration Import/Export main window Completing the installation Completing the installation Operation and shutdown De-activating the RAS Activating the RASOperation and shutdown De-activating the RAS Contacting Patton for assistance Returns for credit Warranty coverageOut-of-warranty service Contact informationRMA numbers Return for credit policyShipping instructions

3125 specifications

The Patton Electronics 3125 is a versatile, high-performance device designed for a variety of communication applications. Known for its durability and reliability, this product has made a name for itself in the realm of network connectivity and data communication.

One of the standout features of the 3125 is its support for both T1 and E1 serial data connections. This flexibility allows users to adapt the device to different network environments, making it suitable for various applications ranging from remote access to integrating legacy systems with modern networks. The device supports frame relay and PPP protocols, which are critical for ensuring efficient data transfer across networks.

The Patton 3125 is equipped with advanced technologies that enhance its functionality. For instance, it incorporates an intelligent line monitoring feature, which helps identify and troubleshoot line faults automatically. This capability can minimize downtime, offering users a more reliable communication experience and reducing the need for on-site maintenance.

Another significant characteristic of the 3125 is its built-in network interface card (NIC) support, which allows seamless integration with IP networks. This feature is particularly valuable for businesses looking to modernize their infrastructure without completely overhauling existing systems. Furthermore, the device supports various signaling protocols, including CAS, NI1, and NI2, which facilitates compatibility with different telecom services.

Additionally, the Patton 3125 comes equipped with a user-friendly web-based interface, making configuration and management straightforward. This feature is particularly beneficial for network administrators, allowing them to monitor performance and adjust settings remotely. The device also supports SNMP for enhanced network management capabilities, further streamlining operational efficiency.

In terms of physical characteristics, the Patton 3125 is built to withstand challenging environments. Its robust casing ensures durability, and it features various mounting options for easy installation in different settings, whether in a data center or an office environment.

Overall, the Patton Electronics 3125 stands out for its combination of flexibility, advanced technology, and ease of use, making it a valuable asset for organizations seeking reliable communication solutions. Whether connecting legacy systems or enabling high-speed data transfer, the 3125 meets the demanding needs of today’s network landscape.