TP-Link TL-SG1048/TL-SG1024, TL-SG1204D/TL-SG1016 manual Site Requirements, Temperature/Humidity

Page 11

Gigabit Unmanaged Switch

Site Requirements

Temperature/Humidity





Please keep a proper temperature and humidity in the equipment room. Too high/low humidity may lead to bad insulation, electricity leakage, mechanical property changes and corrosions. Too high temperature may accelerate aging of the insulation materials and can thus significantly shorten the service life of the device. For normal temperature and humidity of the device, please check the following table.

Environment

Temperature

Humidity

 

 

 

Operating

0~ 40

10% ~ F0%RH Non-condensing

 

 

 

Storage

-40~ F0

5% ~ F0%RH Non-condensing

 

 

 

Clearness

The dust accumulated on the Switch can be absorbed by static electricity and result in poor contact of metal contact points. Some measures have been taken for the device to prevent static electricity, but too strong static electricity can cause deadly damage to the electronic elements on the internal circuit board. To avoid the effect of static electricity on the operation of the Switch, please attach much importance to the following items:

Dust the device regularly, and keep the indoor air clean.

Keep the device well grounded and ensure static electricity has been transferred.

Electromagnetic Interference

Electronic elements including capacitance and inductance on the device can be affected by external interferences, such as conducted emission by capacitance coupling, inductance coupling, and impedance coupling. To decrease the interferences, please make sure to take the following measures:

Use the power supply that can effectively filter interference from the power grid.

Keep the device far from high-frequency, strong-current devices, such as radio transmitting station.

Use electromagnetic shielding when necessary.

Installation 06

Image 11
Contents Installation Guide Page CE Mark Warning Copyright & Trademarks FCC StatementConventions Related Document About this Installation GuideAudience Contents Product Overview FeaturesCccccccccc Introduction Front Panel AppearanceLEDs Rear PanelPower Socket Safety Precautions CCCCCCCCCCInstallationPackage Contents Site Requirements Temperature/HumidityLightening Protection Installation ToolsRack Installation Product InstallationDesktop Installation Fffffffffff Rack Installation Requirements for Cabling Outdoors Cccccccccc Lightning ProtectionCabling Reasonably Requirements for Cabling Indoors Connect to Ground Connecting to the Grounding BarEquipotential Bonding Connecting to the Ground via the Power SupplyUse Lightning Arrester Lightning Protection Ethernet Port Verify InstallationPower On CCCCCCCCCCConnectionInitialization Qqqq The Power LED is not lit Appendix a TroubleshootingFCC, CE Appendix B SpecificationsAppendix C Technical Support Gigabit Unmanaged Switch Page F106503774\ Rev