Polycom DOC2559A manual Component Description

Page 31

Polycom RMX 4000 Hardware Guide

Table 1-5Polycom RMX 4000 Component Description (Continued)

Component

Description

 

 

AC/DC Power

The AC Power Supply drawers are located below the

Supply Modules

MPM+/MPMx Cards and are connected to the backplane

 

by means of a power connector. Operating at 100-240

 

volts AC 50/60 Hz all power supplies have built-in load

 

sharing capabilities.

 

On systems with DC current, the Power Rail Module

 

(PRM) provides direct current to the rear of the RMX

 

through the backplane.

 

 

Fan Drawer

Eight fans are mounted sideways and stacked in a

 

drawer. The drawer is connected to the Back-plane by a

 

connector.

 

Airflow is from right to left, and out the side of the MCU.

 

Each time a board temperature sensor passes one of its

 

thresholds an event is sent to the ShelfManager,

 

whereupon an threshold alert is posted on the RMX

 

Manager, and increases the fans speed. There are

 

currently 3 sets of thresholds: Normal, Major and Critical.

 

When the temperature reaches a critical threshold (and

 

the fan’s speed increase did not resolve the issue), the

 

controller of the relevant board initiates a shut down.

 

 

Multi Processor

The MPM+ cards, perform the various RTP, audio and

Module+ (MPM+)

video processing functions on the RMX 4000 unit. TI

Card

C6455 processors are at the core of each MPM+ card

 

which are available in the following assemblies:

 

MPM+20 (20 CIF resources)

 

MPM+40 (40 CIF resources)

 

MPM+80 (80 CIF resources)

 

Note: An MPM+ located (on the front panel) must face

 

opposite (same slot level) an RTM LAN card (installed on

 

the rear panel). For more information, see "RTM LAN” on

 

page 1-31.

 

 

1-25

Image 31
Contents Polycom RMX 4000 Hardware Guide USA Συμμορφωνεται Προσ ΤΙΣ Ουσιωδεισ Απαιτησεισ ΚΑΙ ΤΙΣ Regulatory Notices Table of Contents Component Replacement Hardware Description RMX 4000 Specifications Following table summarizes the different system capacities RMX 4000 System CapacitiesResource Type MPMx S MPMx D MPMx Resource CapacitiesMPM+ Resource Capacities Operating Mode Selection During Startup / Restart MCU Mode GuidelinesMPMx and MPM+ Modes Polycom RMX 4000 Hardware Guide Site Safety Requirements Safety RequirementsRack Mount Safety Precautions General Installation PrecautionsUnpacking the RMX Installing the RMXPolycom RMX 4000 Hardware Guide Standalone RMX 4000 Installation Installing the RMX in a Rack or as a StandaloneRack Mount Preparations Placing the RMX 4000 in a 19 Rack 2Installing chassis runners and RMX in a rack3RMX 4000 Rack Mount 4Removing and attaching 19 and 23 brackets Placing the RMX 4000 in a 23 RackTo reverse mount the RMX 4000 on a 19 rack Reverse Mounting the RMX 4000 in a RackConnecting the RMX 4000 to Power Sources Connecting the RMX 4000 to AC Power Connecting the RMX 4000 to -48DC Selv Power Types of DC Circuit Breakers installed on the RMX To connect the cables AC and DC systems RTM-IP Connecting Cables on the RMX First-time Power-up RMX 4000 Front Panel RMX 4000 ComponentsShows the front panel of an RMX 4000 DC system Component Description Component Description 9RMX 4000 AC Rear View RMX 4000 Rear Panel10RMX 4000 DC Rear View RTM-IPFollowing items appear on the RMX 4000 rear panel RTM Isdn ISDN/PSTN Clock Source RTM LANDC Power Rail Module AC Power Entry Module PEMComponent Slot Allocation RTM ISDN/RTM RMX 4000 Front Panel LEDs RMX 4000 LEDsCard removal Initiated The card Cntl 4000 Unit RTM-IP RMX 4000 Rear Panel LEDsRTM LAN RTM Isdn Hardware Description Component Replacement Component Replacement Handle Using the Modified PMC Compatible Ejector LeverReplacing the Cntl 4000 Module Replacing an AC Power Supply Module Replacing an AC Power Entry Module PEM Replacing a DC Power Rail Module PRM Component Replacement Carefully slide the Fan drawer out through the front panel Replacing the Fan DrawerInserting an Air Filter Optional in the Fan Drawer Removing the MPM+/MPMx Card from the MCU Replacing an Faulty MPM+/MPMx CardComponent Replacement Installing the Replacement MPM+/MPMx Card Replacing a RTM Isdn Card Installing an MPM+/MPMx Card on the RMXPRI Cables Replacing the RTM-IP Replacing the RTM LAN Replacing the Fabric Switch Module FSM Polycom RMX 4000 Hardware Guide