Polycom DOC2559C manual Resource Capacities per Card Type MPM+ and MPMx, Resource Type

Page 12

Chapter 1- Hardware Description

Resource Capacities per Card Type (MPM+ and MPMx)

Table 1-5summarizes resource capacities of the various cards that can be installed in an RMX per resolution in CP conferencing mode.

Table 1-5MPMx and MPM+ Resource Capacity per Resolution in CP

 

Maximum Possible Resources Per Card

Resource Type

 

 

 

MPM+

MPMx

 

 

 

HD720p60/HD1080p30

Not

15

Symmetric

Applicable

 

 

 

 

HD720p60/HD1080p30

10

15

Asymmetric

 

 

 

 

 

HD720p30/ SD 60

20

30

 

 

 

SD 30 (H.264)/ 4CIF 60

30

60

 

 

 

4CIF (H.263)

30

30

 

 

 

CIF (H.264)

80

90

 

 

 

CIF (H.263)

80

60

 

 

 

Audio only (VoIP)

400

360

 

 

 

Table 1-6summarizes resource capacities of the various cards that can be installed in an RMX per line rate in VSW conferencing mode.

Table 1-6MPMx and MPM+ Resource Capacity per Line Rate in VSW

 

Maximum Possible Resources Per Card

Resource Type

 

 

 

MPM+

MPMx

 

 

 

VSW 2Mbps

80

80

 

 

 

VSW 4Mbps

40

40

 

 

 

VSW 6Mbps

20

20

 

 

 

1-6

Image 12
Contents Polycom RMX 4000 Hardware Guide USA Συμμορφωνεται Προσ ΤΙΣ Ουσιωδεισ Απαιτησεισ ΚΑΙ ΤΙΣ Regulatory Notices Russian Communication CertificateTable of Contents MPM+ and MPMx Media Cards RMX 4000 Rear Panel RTM-IP ISDN/PSTN Clock SourceHardware Description Power Supply Power ConsumptionPhysical Media Protocols RMX 4000 System Capacities Conferencing Capacities Following table summarizes the different system capacities EnvironmentSystem Functions MPM+ Mode MPMx Mode Resource Capacities per Card Assembly MPMx CardMPM+ Card Resource Capacities per Card Type MPM+ and MPMx Maximum Possible Resources Per CardResource Type MPMxSafety Requirements Site Safety RequirementsGeneral Installation Precautions Rack Mount Safety PrecautionsInstalling the RMX Unpacking the RMXHardware Description Installing the RMX in a Rack or as a Standalone Standalone RMX 4000 InstallationRack Mount Preparations 2Installing chassis runners and RMX in a rack Placing the RMX 4000 in a 19 Rack3RMX 4000 Rack Mount Placing the RMX 4000 in a 23 Rack 4Removing and attaching 19 and 23 bracketsReverse Mounting the RMX 4000 in a Rack To reverse mount the RMX 4000 on a 19 rackConnecting the RMX 4000 to Power Sources Connecting the RMX 4000 to AC Power Make sure that the power button is switched OFF on the RMXConnecting the RMX 4000 to -48DC Selv Power Types of DC Circuit Breakers installed on RMX Type a Type BConnecting Cables to the RMX To connect the cables AC and DC systems RTM-IPFirst-time Power-up For more information about specific card connections, seeRTM LAN on RMX 4000 Components RMX 4000 Front Panel8shows the front panel of an RMX 4000 DC system Component Description Card Configuration Mode Selection During Startup / Restart MPM+ and MPMx Media CardsRMX 4000 Rear Panel 9RMX 4000 AC Rear ViewRTM-IP 10RMX 4000 DC Rear ViewFollowing items appear on the RMX 4000 rear panel LAN 3 CntlRTM Isdn Standby button Toggle between CPU activation and standbyAC Power Entry Module PEM ISDN/PSTN Clock SourceDC Power Rail Module Component Slot AllocationSlot ID/No Card/Component Requirement RTM ISDN/RTM RMX 4000 Front Panel LEDs Following items appear on the RMX 4000 front panelComponent LED Color DescriptionCard removal Initiated The card Card Insertion Initiated If duringCntl 4000 Unit RMX 4000 Rear Panel LEDs RTM-IPFollowing LEDs appear on the RTM-IP 4000 card LED Color Description NameFollowing LEDs appear on the RTM LAN Function NameRTM Isdn Following LEDs appear on the RTM IsdnComponent Replacement Component Replacement Using the Modified PMC Compatible Ejector Lever HandleReplacing the Cntl 4000 Module Replacing an AC Power Supply Module Replacing an AC Power Entry Module PEM Replacing a DC Power Rail Module PRM Component Replacement Replacing the Fan Drawer Carefully slide the Fan drawer out through the front panelInserting an Air Filter Optional in the Fan Drawer Replacing an Faulty MPM+/MPMx Card Removing the MPM+/MPMx Card from the MCUComponent Replacement Installing the Replacement MPM+/MPMx Card Installing an MPM+/MPMx Card on the RMX Replacing the RTM Isdn CardPRI Cables Replacing the RTM-IP Replacing the RTM LAN Replacing the Fabric Switch Module FSM Polycom RMX 4000 Hardware Guide