Lindy Switch manual Connecting via dial up modem or Isdn link, If you need to enter a port number

Page 38

Connecting via dial up (modem or ISDN) link

When you use a modem or ISDN link to make the connection, the LINDY KVM IP uses standard network protocols to create a private two-device network. This approach ensures consistency and allows you to use exactly the same VNC viewer or browser to view the hosts systems. This is achieved using PPP (Point to Point Protocol) and means that you need to use a dial-up networking method to initiate the connection. Such software is standard with operating systems such as Windows, Linux and Mac OS.

To initiate a dial up link

1Using a system that has a modem or ISDN adapter installed, locate the dial-up networking option on your system. Please refer to your system documentation for more information.

2Using the dial-up networking option, enter the telephone/ISDN number where the LINDY KVM IP can be contacted.

3Initiate the call and when the link is made, continue with either the standard VNC viewer or browser connection.

Note: For the viewer network connection address, you must use the IP address that the admin user has set as the Server address (or PPP server IP address) within the Modem configuration screen.

Downloading VNC viewer from the LINDY KVM IP

The LINDY KVM IP has the ability to distribute its own VNC viewer application.

To download the VNC viewer

1Open your Web browser.

2Enter the network address where the LINDY KVM IP is situated (in the form: http://192.168.0.3) and make the link.

3In the opening LINDY KVM IP screen, click the link that offers to download the secure VNC viewer ‘from the unit’.

4Save the download file (vncviewer.exe) to your system.

5Select and run the downloaded file and then connect to the LINDY KVM IP using the VNC viewer application.

If you need to enter a port number

Usually, when you make a network connection to the LINDY KVM IP (either using the VNC viewer or a Web browser) you simply enter the IP address, i.e. 192.168.0.3. However, if a special configuration is necessary, then you may be asked to specify a port number as well as the IP address.

What is a port?

To enter a port number in a Web browser

1Enter the required IP address in the usual Address box, i.e. http://192.168.0.3

2At the end of the IP address, add a single colon and then enter the port number (in this example, the required port number is 8000),

i.e. http://192.168.0.3:8000

3Continue with the standard Web browser instructions.

To enter a port number in VNC viewer

1Enter the required IP address in the usual ‘Server’ box, i.e. http://192.168.0.3

2At the end of the IP address, add two colons and then enter the port number (in this example, the required port number is 115900),

i.e. http://192.168.0.3::115900

3Continue with the standard VNC viewer instructions.

   



37

Image 38
Contents IP Access Switch Plus DVI Audio Contents Index Modem/ISDN port Virtual Media featureLocal user console Dual formats for flexibilityLindy KVM IP features front and rear What’s in the box What you may additionally needDouble unit rack brackets MountingSingle unit rack brackets Full width of a 1U rack slotLocal console connections Keyboard and mouse Video Audio ConnectionsHost computer links Keyboard and mouse Single host computer or many?Host computer links Video To make a video linkTo make an audio link Host computer links AudioHost computer links Virtual Media To make an Virtual Media linkLocal console. Why? Local console connections Keyboard and mouseTo connect a local keyboard and mouse   Local console connections Video To connnect a local video monitorTo connect local speakers Local console connections AudioIP network port To connect the IP network portConnect the power leads to a nearby main supply socket Power supply connectionTo connect the power supply Modem/ISDN portPower control port To connect and address the switch boxesInitial configuration occurs as two distinct parts Initial configurationPart 1 Local configuration Part 1 Local configurationTo perform the initial local configuration Edit the Unit config screen. The key elements here areViewer encryption settings Encryption settingsLindy KVM IP encryption settings EncryptionHot plugging and mouse restoration Which restore setting do I use?To restore mouse operation when hot plugging Recognising an IntelliMouse-style mouseTo invoke a configuration reset by switch Resetting the configurationLindy KVM IP asks for an unknown admin password Lindy KVM IP does not display the configuration sequencePart 2 Remote configuration To perform the remote configurationPositioning Lindy KVM IP in the network Networking issuesPort settings Placing Lindy KVM IP behind a router or firewallDNS addressing AddressingTo discover a DHCP-allocated IP address Firewall/router addressPorts Placing Lindy KVM IP alongside the firewallEnsuring sufficient security To configure the power sequences for each host computer Power switching configurationPower control sequences Power OffKvmadmin -getconfig kvm1.cfg Kvmadmin utilityKvmadmin command ip address parameters Kvmadmin -setusers users.csvConfigure network option Performing a flash upgradeTo perform a flash upgrade Important Wait until the upgrade is completeTo make a local connection Connecting to the Lindy KVM IPLocal connection To view the local control menuRemote connections To avoid the ‘hall of mirrors’ effectRemote connection by VNC viewer To connect using the VNC viewerTo connect using your Web browser Remote connection by Web browserMenu bar Using the viewer windowWhen using the viewer window For the VNC viewer, the local cursor is a dot ConfigureMouse pointers To select a hostAuto calibrate Access mode shared/privatePower control Re-synchronise mouseMouse Control Single Mouse ModeControls Resync MouseKeyboard Control When entering codesVideo Settings InfoWhen the screen contains only host system information AdjustedSettings for all items Increased by 50% when a slow link is detectedVirtual Media To remotely transfer files to a host computerIf you need to enter a port number Connecting via dial up modem or Isdn linkDownloading VNC viewer from the Lindy KVM IP Windows Viewer encryption settingsSupported web browsers LinuxTroubleshooting Getting assistanceSelect the ‘Configuration’ option to display Appendix 1 Local configuration menusTo access the local configuration menus Select the required optionUnit configuration Network configuration Modem configuration To reset the Lindy KVM IP configuration Reset configurationThis option allows you to completely reset the Lindy KVM IP To clear IP access control Clear IP access controlWhat is IP access control? Auto select Appendix 2 VNC viewer connection optionsColour/Encoding Preferred encodingInputs Enable all inputsDisable all inputs view-only mode CustomiseScaling MiscIdentities Defaults ReloadDefaults Save Load / SaveAppendix 3 VNC viewer window options Security Appendix 4 Browser viewer optionsEncoding and colour level Main configuration menu Logged on users Appendix 5 Remote configuration menusTo access the remote configuration menus Click the required optionUser accounts Firmware Version Screensaver TimeoutHardware Version Host Keyboard LayoutAdvanced unit configuration Time & date configuration IP Gateway IP Access ControlIP Network Mask To reorder access control entries Setting IP access controlTo define a new IP access control entry To edit/remove access control entriesModem port Serial port configurationPower control port Host configuration To create a new host entryHotkey sequences Port/host addressing using Port DirectHotkey sequences and Port Direct Port DirectSyslog Server IP Address Logging and statusTo copy and paste the log For further details To get hereNet masks Appendix 6 Addresses, masks and portsIP addresses Answer YESBinary equivalent Net masks the binary explanationOperation with net mask Binary octet afterAll locations Calculating the mask for IP access controlSingle locations Address rangesSecurity issues with ports Ports+5V Appendix 7 Cable and connector specificationsRS232 serial mouse to PS/2 converter cable 12VCreating macro sequences Appendix 8 Hotkey sequence codesPermissible key presses Appendix 9 Supported video modes Safety information Other products in the CPU Switch rangeWarranty General Public License LinuxEnd user licence agreement FCC Compliance Statement United States Radio Frequency EnergyEuropean EMC directive 89/336/EEC Canadian Department of Communications RFI statementItalia Email info@lindy.ch Germany France ItaliaLINDY-Elektronik GmbH Video source setting IndexConnections

Switch specifications

Lindy Switch is a pivotal innovation in the realm of audio-visual and data transmission technologies, designed to facilitate seamless switching between multiple signal sources. This device serves numerous applications, from broadcasting and live events to professional AV setups and corporate environments. One of its standout features is the ability to handle multiple input and output formats, enabling users to switch between HDMI, DisplayPort, USB, and more, depending on their specific needs.

The technology behind Lindy Switch is built to ensure high-definition signal integrity, with support for resolutions up to 4K at 60Hz. This makes it an ideal choice for environments that demand high-quality video output, such as home theaters and conference rooms. Furthermore, the device is engineered for low latency, ensuring that signal switching occurs in real-time without discernible lag, crucial for live performances and presentations.

Lindy Switch incorporates advanced features such as automatic switching, which detects the active input source and seamlessly transitions to it, making it user-friendly even for those who are not tech-savvy. Additionally, the device often includes remote control capabilities, allowing users to manage inputs from a distance, enhancing convenience in larger spaces.

Another characteristic that sets Lindy Switch apart is its robust build quality. Designed for reliability, it features durable connectors and housing, safeguarding against wear and tear from frequent use. This reliability extends to its compatibility with a wide range of operating systems and devices, including Windows, macOS, and various gaming consoles.

In summary, Lindy Switch exemplifies cutting-edge technology in signal management, boasting features such as high-definition support, low latency, automatic switching, and versatile compatibility. Its solid construction and user-friendly interface make it a vital tool for professionals and enthusiasts alike, ensuring optimal performance in diverse audio-visually demanding environments. Whether for a home cinema or a corporate setting, Lindy Switch meets the needs of modern users who rely on efficient and high-quality signal switching solutions.