Lindy Switch manual To perform the initial local configuration

Page 17

To perform the initial local configuration

1 Edit the Unit config screen. The key elements here are:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Admin password

 

 

IP Access

+ Unit

Config

Hardware

Rev

1

 

 

 

 

 

 

 

 

 

Enter a password of at least

 

 

 

 

 

 

 

 

 

six characters that has a mix

Firmware

1.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

of letters and numerals. The

Keybd

Layout

 

UK

 

 

 

 

 

 

 

 

 

 

background colour provides

Admin

Passwd

 

 

 

 

 

 

 

 

 

 

 

 

an indication of password

Unit

Name

 

 

 

 

 

 

 

 

 

 

 

 

suitability and is initially red

Hot

Keys

 

Ctrl+Alt

 

 

 

 

 

 

to indicate that the password

Screensaver

 

10

mins

 

 

 

 

 

 

 

is not sufficient. When a

Time

 

 

 

21

:

27

:

31

 

 

 

 

password with reasonable

Date

 

 

 

15

 

Apr

 

 

2004

 

strength has been entered it

Encryption

 

Prefer Off

 

 

 

 

 

 

changes to blue.

Video

Source

 

Analogue

 

 

 

 

 

 

Time and Date

Screen

1 of

5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Next

Set these correctly as all entries

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

in the activity log are time

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

stamped using them.

Encryption

Arrange this setting according to your security requirements. See Encryption settings for a description of the issues and the settings.

When all items are correct, select the Next option to display the next screen.

2 Edit the Network config screen. The key elements here are:

 

 

 

 

 

 

 

 

 

Use DHCP/IP Address/Net

 

 

Network

Config

Mask/Gateway

 

 

 

 

 

 

 

 

 

MAC

Address

 

00:0F:58:00:00:04

You need to either set the

 

DHCP option to ‘Yes’ or

Use

DHCP

 

No

 

 

 

 

 

 

 

 

 

 

manually enter a valid IP

IP Address

 

192.168.42.154

 

 

 

 

 

address, Net mask and

Net

Mask

 

255.255.255.0

 

 

 

 

 

Gateway. See Networking

Gateway

 

 

 

 

 

 

 

 

 

 

 

 

 

 

issues for more details.

VNC

Port

 

5900

 

 

 

 

 

 

 

 

 

 

 

 

HTTP

Port

 

80

 

 

 

 

 

VNC and HTTP ports

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

These should remain set to

Screen 2 of

5

 

 

 

 

 

5900 and 80, respectively,

 

 

 

Next

 

unless they clash with an

existing setup within the network. See Networking issues for more details.

When all items are correct, select the Next option to display the next screen.

3 If necessary, edit the Modem config screen.

 

 

 

 

 

 

 

 

The default items here are

 

 

 

 

 

Modem Config

 

 

 

 

 

 

 

 

 

 

perfectly adequate for the

 

 

 

 

 

 

 

 

 

majority of modem and ISDN

 

 

Server

IP

192.168.3.1

 

 

 

 

 

 

terminal adapter installations.



 

Client

IP

192.168.3.2

 

 

 

 

 

 

 

Baud

Rate

115200

 

 

 

The Server IP and Client IP

 

 

Init

String

ATZS0=1

 

 

 

addresses are used to form

 

 

 

 

 

 

 

 

 

an isolated two-device PPP

 

 

 

 

 

 

 

 

 

network connection via the

 

 

 

 

 

Initialize Port

 

 

 

 

 

 

 

dial up link. Their settings are

 

 

 

 

 

Restore Defaults

 

 

 

 

 

 

 

 

 

 

 

 

 

not related to any other ‘real’

 

 

 

 

 

 

 

 

 

 

 

Screen

3 of

5

 

 

 

network settings within the

 

 

 

 

Next

 

 

 

 

LINDY KVM IP.



 

 

 

 

 

 

 

 

When all items are correct, select the Next option to display the next screen.

 

4 Move the mouse and enter changing key sequences within this screen.

 

Random data is

required to



 

Secure Keys

 

 

 

generate encryption keys

 

 

for secure VNC

access

 

 

Please move the mouse or

 

 

press keys until the bar

 

becomes full

 

 

 

 

 

 

{

{

 

 

 

Screen 4 of 5

 

 

 

With every mouse move and keypress, the single dash will move across the



screen (unless the same key is pressed repeatedly). Periodically, a new star

 

character will be added to the bar as the random data are accepted as part of the new encryption key. When the bar is full, the final encryption keys for your LINDY KVM IP will be created – this process takes roughly 30 to 40 seconds.

continued

16

Image 17
Contents IP Access Switch Plus DVI Audio Contents Index Local user console Virtual Media featureModem/ISDN port Dual formats for flexibilityLindy KVM IP features front and rear What you may additionally need What’s in the boxSingle unit rack brackets MountingDouble unit rack brackets Full width of a 1U rack slotHost computer links Keyboard and mouse ConnectionsLocal console connections Keyboard and mouse Video Audio Single host computer or many?To make a video link Host computer links VideoHost computer links Virtual Media Host computer links AudioTo make an audio link To make an Virtual Media linkTo connect a local keyboard and mouse Local console connections Keyboard and mouseLocal console. Why?   To connnect a local video monitor Local console connections VideoIP network port Local console connections AudioTo connect local speakers To connect the IP network portTo connect the power supply Power supply connectionConnect the power leads to a nearby main supply socket Modem/ISDN portTo connect and address the switch boxes Power control portPart 1 Local configuration Initial configurationInitial configuration occurs as two distinct parts Part 1 Local configurationEdit the Unit config screen. The key elements here are To perform the initial local configurationLindy KVM IP encryption settings Encryption settingsViewer encryption settings EncryptionTo restore mouse operation when hot plugging Which restore setting do I use?Hot plugging and mouse restoration Recognising an IntelliMouse-style mouseLindy KVM IP asks for an unknown admin password Resetting the configurationTo invoke a configuration reset by switch Lindy KVM IP does not display the configuration sequenceTo perform the remote configuration Part 2 Remote configurationPort settings Networking issuesPositioning Lindy KVM IP in the network Placing Lindy KVM IP behind a router or firewallTo discover a DHCP-allocated IP address AddressingDNS addressing Firewall/router addressPorts Placing Lindy KVM IP alongside the firewallEnsuring sufficient security Power control sequences Power switching configurationTo configure the power sequences for each host computer Power OffKvmadmin command ip address parameters Kvmadmin utilityKvmadmin -getconfig kvm1.cfg Kvmadmin -setusers users.csvTo perform a flash upgrade Performing a flash upgradeConfigure network option Important Wait until the upgrade is completeLocal connection Connecting to the Lindy KVM IPTo make a local connection To view the local control menuTo avoid the ‘hall of mirrors’ effect Remote connectionsTo connect using your Web browser To connect using the VNC viewerRemote connection by VNC viewer Remote connection by Web browserMenu bar Using the viewer windowWhen using the viewer window Mouse pointers ConfigureFor the VNC viewer, the local cursor is a dot To select a hostPower control Access mode shared/privateAuto calibrate Re-synchronise mouseControls Single Mouse ModeMouse Control Resync MouseVideo Settings When entering codesKeyboard Control InfoSettings for all items AdjustedWhen the screen contains only host system information Increased by 50% when a slow link is detectedTo remotely transfer files to a host computer Virtual MediaIf you need to enter a port number Connecting via dial up modem or Isdn linkDownloading VNC viewer from the Lindy KVM IP Supported web browsers Viewer encryption settingsWindows LinuxGetting assistance TroubleshootingTo access the local configuration menus Appendix 1 Local configuration menusSelect the ‘Configuration’ option to display Select the required optionUnit configuration Network configuration Modem configuration To reset the Lindy KVM IP configuration Reset configurationThis option allows you to completely reset the Lindy KVM IP To clear IP access control Clear IP access controlWhat is IP access control? Colour/Encoding Appendix 2 VNC viewer connection optionsAuto select Preferred encodingDisable all inputs view-only mode Enable all inputsInputs CustomiseMisc ScalingDefaults Save Defaults ReloadIdentities Load / SaveAppendix 3 VNC viewer window options Security Appendix 4 Browser viewer optionsEncoding and colour level To access the remote configuration menus Appendix 5 Remote configuration menusMain configuration menu Logged on users Click the required optionUser accounts Hardware Version Screensaver TimeoutFirmware Version Host Keyboard LayoutAdvanced unit configuration Time & date configuration IP Gateway IP Access ControlIP Network Mask To define a new IP access control entry Setting IP access controlTo reorder access control entries To edit/remove access control entriesModem port Serial port configurationPower control port To create a new host entry Host configurationHotkey sequences and Port Direct Port/host addressing using Port DirectHotkey sequences Port DirectTo copy and paste the log Logging and statusSyslog Server IP Address For further details To get hereIP addresses Appendix 6 Addresses, masks and portsNet masks Answer YESOperation with net mask Net masks the binary explanationBinary equivalent Binary octet afterSingle locations Calculating the mask for IP access controlAll locations Address rangesPorts Security issues with portsRS232 serial mouse to PS/2 converter cable Appendix 7 Cable and connector specifications+5V 12VCreating macro sequences Appendix 8 Hotkey sequence codesPermissible key presses Appendix 9 Supported video modes Warranty Other products in the CPU Switch rangeSafety information General Public License LinuxEnd user licence agreement European EMC directive 89/336/EEC Radio Frequency EnergyFCC Compliance Statement United States Canadian Department of Communications RFI statementItalia Email info@lindy.ch Germany France ItaliaLINDY-Elektronik GmbH Index Video source settingConnections

Switch specifications

Lindy Switch is a pivotal innovation in the realm of audio-visual and data transmission technologies, designed to facilitate seamless switching between multiple signal sources. This device serves numerous applications, from broadcasting and live events to professional AV setups and corporate environments. One of its standout features is the ability to handle multiple input and output formats, enabling users to switch between HDMI, DisplayPort, USB, and more, depending on their specific needs.

The technology behind Lindy Switch is built to ensure high-definition signal integrity, with support for resolutions up to 4K at 60Hz. This makes it an ideal choice for environments that demand high-quality video output, such as home theaters and conference rooms. Furthermore, the device is engineered for low latency, ensuring that signal switching occurs in real-time without discernible lag, crucial for live performances and presentations.

Lindy Switch incorporates advanced features such as automatic switching, which detects the active input source and seamlessly transitions to it, making it user-friendly even for those who are not tech-savvy. Additionally, the device often includes remote control capabilities, allowing users to manage inputs from a distance, enhancing convenience in larger spaces.

Another characteristic that sets Lindy Switch apart is its robust build quality. Designed for reliability, it features durable connectors and housing, safeguarding against wear and tear from frequent use. This reliability extends to its compatibility with a wide range of operating systems and devices, including Windows, macOS, and various gaming consoles.

In summary, Lindy Switch exemplifies cutting-edge technology in signal management, boasting features such as high-definition support, low latency, automatic switching, and versatile compatibility. Its solid construction and user-friendly interface make it a vital tool for professionals and enthusiasts alike, ensuring optimal performance in diverse audio-visually demanding environments. Whether for a home cinema or a corporate setting, Lindy Switch meets the needs of modern users who rely on efficient and high-quality signal switching solutions.