Lindy Switch manual Logging and status, To copy and paste the log, Syslog Server IP Address

Page 63

Logging and status

This screen provides various details about the user activity on the LINDY KVM IP.

Note: The log has a maximum capacity of 1000 event lines. After 1000 entries, the oldest entries are overwritten. If log data are important to your installation, ensure a regular backup procedure or use the Syslog Server IP Address option to send log information automatically to another system.

Date and

Type of event, user name and access

time the

method or remote IP address

event

 

occurred

 

Click to clear

Click to

Optionally enter an

Click to

all log entries

refresh

IP address to which

return to

 

the list

the status log should

the main

 

 

be sent

menu

To copy and paste the log

You can copy the information listed within the log and paste it into another application.

1While viewing the log screen, press Ctrl and C, to copy the data into the clipboard.

2In a text application (i.e. Word, WordPad, Notepad) press Ctrl and V, or right mouse click and ‘Paste’.

Syslog Server IP Address

Logging information can optionally be sent, as it occurs, to a separate system using the standard Syslog protocol. Enter the IP address of a suitable system in the field provided.

For further details

For details of the Syslog protocol (RFC number: 3164) http://www.ietf.org/rfc.html

To get here

1Using VNC viewer or a browser, log on as the ‘admin’ user.

2Click the ‘Configure’ button in the top right corner.

3Click the ‘Logging and Status’ option.

   



62

Image 63
Contents IP Access Switch Plus DVI Audio Contents Index Dual formats for flexibility Virtual Media featureLocal user console Modem/ISDN portLindy KVM IP features front and rear What you may additionally need What’s in the boxFull width of a 1U rack slot MountingSingle unit rack brackets Double unit rack bracketsSingle host computer or many? ConnectionsHost computer links Keyboard and mouse Local console connections Keyboard and mouse Video AudioTo make a video link Host computer links VideoTo make an Virtual Media link Host computer links AudioHost computer links Virtual Media To make an audio link   Local console connections Keyboard and mouseTo connect a local keyboard and mouse Local console. Why?To connnect a local video monitor Local console connections VideoTo connect the IP network port Local console connections AudioIP network port To connect local speakersModem/ISDN port Power supply connectionTo connect the power supply Connect the power leads to a nearby main supply socketTo connect and address the switch boxes Power control portPart 1 Local configuration Initial configurationPart 1 Local configuration Initial configuration occurs as two distinct partsEdit the Unit config screen. The key elements here are To perform the initial local configurationEncryption Encryption settingsLindy KVM IP encryption settings Viewer encryption settingsRecognising an IntelliMouse-style mouse Which restore setting do I use?To restore mouse operation when hot plugging Hot plugging and mouse restorationLindy KVM IP does not display the configuration sequence Resetting the configurationLindy KVM IP asks for an unknown admin password To invoke a configuration reset by switchTo perform the remote configuration Part 2 Remote configurationPlacing Lindy KVM IP behind a router or firewall Networking issuesPort settings Positioning Lindy KVM IP in the networkFirewall/router address AddressingTo discover a DHCP-allocated IP address DNS addressingPlacing Lindy KVM IP alongside the firewall Ensuring sufficient securityPorts Power Off Power switching configurationPower control sequences To configure the power sequences for each host computerKvmadmin -setusers users.csv Kvmadmin utilityKvmadmin command ip address parameters Kvmadmin -getconfig kvm1.cfgImportant Wait until the upgrade is complete Performing a flash upgradeTo perform a flash upgrade Configure network optionTo view the local control menu Connecting to the Lindy KVM IPLocal connection To make a local connectionTo avoid the ‘hall of mirrors’ effect Remote connectionsRemote connection by Web browser To connect using the VNC viewerTo connect using your Web browser Remote connection by VNC viewerUsing the viewer window When using the viewer windowMenu bar To select a host ConfigureMouse pointers For the VNC viewer, the local cursor is a dotRe-synchronise mouse Access mode shared/privatePower control Auto calibrateResync Mouse Single Mouse ModeControls Mouse ControlInfo When entering codesVideo Settings Keyboard ControlIncreased by 50% when a slow link is detected AdjustedSettings for all items When the screen contains only host system informationTo remotely transfer files to a host computer Virtual MediaConnecting via dial up modem or Isdn link Downloading VNC viewer from the Lindy KVM IPIf you need to enter a port number Linux Viewer encryption settingsSupported web browsers WindowsGetting assistance TroubleshootingSelect the required option Appendix 1 Local configuration menusTo access the local configuration menus Select the ‘Configuration’ option to displayUnit configuration Network configuration Modem configuration Reset configuration This option allows you to completely reset the Lindy KVM IPTo reset the Lindy KVM IP configuration Clear IP access control What is IP access control?To clear IP access control Preferred encoding Appendix 2 VNC viewer connection optionsColour/Encoding Auto selectCustomise Enable all inputsDisable all inputs view-only mode InputsMisc ScalingLoad / Save Defaults ReloadDefaults Save IdentitiesAppendix 3 VNC viewer window options Appendix 4 Browser viewer options Encoding and colour levelSecurity Click the required option Appendix 5 Remote configuration menusTo access the remote configuration menus Main configuration menu Logged on usersUser accounts Host Keyboard Layout Screensaver TimeoutHardware Version Firmware VersionAdvanced unit configuration Time & date configuration IP Access Control IP Network MaskIP Gateway To edit/remove access control entries Setting IP access controlTo define a new IP access control entry To reorder access control entriesSerial port configuration Power control portModem port To create a new host entry Host configurationPort Direct Port/host addressing using Port DirectHotkey sequences and Port Direct Hotkey sequencesFor further details To get here Logging and statusTo copy and paste the log Syslog Server IP AddressAnswer YES Appendix 6 Addresses, masks and portsIP addresses Net masksBinary octet after Net masks the binary explanationOperation with net mask Binary equivalentAddress ranges Calculating the mask for IP access controlSingle locations All locationsPorts Security issues with ports12V Appendix 7 Cable and connector specificationsRS232 serial mouse to PS/2 converter cable +5VAppendix 8 Hotkey sequence codes Permissible key pressesCreating macro sequences Appendix 9 Supported video modes General Public License Linux Other products in the CPU Switch rangeWarranty Safety informationEnd user licence agreement Canadian Department of Communications RFI statement Radio Frequency EnergyEuropean EMC directive 89/336/EEC FCC Compliance Statement United StatesGermany France Italia LINDY-Elektronik GmbHItalia Email info@lindy.ch Index Video source settingConnections

Switch specifications

Lindy Switch is a pivotal innovation in the realm of audio-visual and data transmission technologies, designed to facilitate seamless switching between multiple signal sources. This device serves numerous applications, from broadcasting and live events to professional AV setups and corporate environments. One of its standout features is the ability to handle multiple input and output formats, enabling users to switch between HDMI, DisplayPort, USB, and more, depending on their specific needs.

The technology behind Lindy Switch is built to ensure high-definition signal integrity, with support for resolutions up to 4K at 60Hz. This makes it an ideal choice for environments that demand high-quality video output, such as home theaters and conference rooms. Furthermore, the device is engineered for low latency, ensuring that signal switching occurs in real-time without discernible lag, crucial for live performances and presentations.

Lindy Switch incorporates advanced features such as automatic switching, which detects the active input source and seamlessly transitions to it, making it user-friendly even for those who are not tech-savvy. Additionally, the device often includes remote control capabilities, allowing users to manage inputs from a distance, enhancing convenience in larger spaces.

Another characteristic that sets Lindy Switch apart is its robust build quality. Designed for reliability, it features durable connectors and housing, safeguarding against wear and tear from frequent use. This reliability extends to its compatibility with a wide range of operating systems and devices, including Windows, macOS, and various gaming consoles.

In summary, Lindy Switch exemplifies cutting-edge technology in signal management, boasting features such as high-definition support, low latency, automatic switching, and versatile compatibility. Its solid construction and user-friendly interface make it a vital tool for professionals and enthusiasts alike, ensuring optimal performance in diverse audio-visually demanding environments. Whether for a home cinema or a corporate setting, Lindy Switch meets the needs of modern users who rely on efficient and high-quality signal switching solutions.