Lindy MC5-IP manual Remote user via User Station, Cable lengths for remote user locations

Page 11

Remote user (via User Station)

Up to four users can be placed a maximum of 300 metres (980 feet) from the MC5 unit. Remote users are connected via a User Station extender module and suitable category 5, 5e or 6 cabling (with no crossover). The MC5-IP models provide two remote user ports.

LOCAL

REMOTE

GLOBAL

USER

USER

USER

 

U S

IP

POWER

 

MODEM

IN

 

/ISDN

CAM

 

 

COMPUTER

POWER

SYSTEM

SWITCH

3Lay a suitable length of category 5, 5e or 6 cabling between the User Station module and the MC5 unit. Please refer to the section Cable lengths for remote user locations opposite.

4 Attach the connector of the cable run to the socket of the User Station.

tch MC 5



Cable lengths for remote user locations

The maximum length of cable between a remote user and the MC5 unit can be up to 300 metres (980 feet). However, bear in mind that the overall distance between any remote user and any computer system must not exceed 300 metres (980 feet).

Overall maximum length between any remote user and any host system must not exceed 300 metres (980 feet)

REMOTE

U S

CAM

COMPUTER

USER

 

 

SYSTEM

 

300 metres (980 feet)

50 metres

 

 

maximum

(160 feet)

 

 

 

maximum

 

Category 5, 5e or 6

cable leading to MC5

unit

From power adapter

User Station

module

5At the other end of the cable run, attach the cable connector to one of the sockets labelled CATx USER PORTS on the rear panel of the MC5 unit.

 

In situations where any computer system will be placed a significant distance from the MC5 unit, ensure that the distance to any remote user is similary less

!

 

 

 

 

 

 

W

 

 

 

 

 

 

P RJ45

CO

 

 

 

 

ANEL

 

 

 

 

TO

 

ARNINGARENNECT

 

 

K

 

 

D

VM

 

FOR ORS

 

 

O

NO

 

 

 

 

 

 

EQ

 

 

 

TELEPHON

UIPMENTCONNEC THIS

 

O

TIO

 

 

 

CONNECT

NL

 

N

 

 

 

 

 

O Y.

 

CA

MC5 rear panel

than 300 metres (980 feet).

To connect a remote user

 

 

 

1

Place a User Station extender unit adjacent to the remote user location.

2

Attach the video monitor,

 

tati

Sw

rS

 

 

keyboard, mouse, power

Use

KVM

 

 

 

 

adapter (and speaker)

 

 

.com

 

connectors to the sockets

 

 

 

 

 

.lindy

 

of the User Station

 

 

 

 

 

www

module.

5V

SYSTEMSNETW

 

OR

 

K

4A

 

OR

OPTIONS

PWR

IN

Category 5, 5e or 6 cable from User Station module

Tx 4

3

USER

PORTS

 

 

 

 

2

 

 

POWER

CONTROL

 

 

1

Note: The MC5 model shown here is a non-IP version. The IP-version provides only remote user ports 3 and 4.

 



From mouse

From keyboard

User Station

module

From video monitor

6Where necessary, use the in-built video compensation feature of the User Station module to eliminate any effects caused by the cable run. However, ensure that the links between the computers and the MC5 have been compensated first. See remote user video compensation for details.

10

Image 11
Contents  MC5-IP KVM SwitchContents Further information Index CAM formats Local user One user can be connected directly to the MC5  Many computersFront panel buttons MC5 features front and rearIndicators Power control port Upgrade port Modem port IP models onlySwitc What’s in the box What you may additionally needRack brackets Mounting   ConnectionsMC5 rear panel Local userTo connect the local user port To connect a remote user Remote user via User StationCable lengths for remote user locations IP network link Global user IP network portTo connect the Global user IP network port Category 5, 5e or Cable from CAM Access ModuleTo connect a computer system MC5 rear panel Cable from modem Or Isdn adapter Modem/ISDN portTo connect a modem or Isdn adapter Output lead from Power adapter Power in connectionTo connect the power supply To connect and address the switch boxes Power control portCascade tree Cascading multiple unitsSee also How cascade connections operate 43 41 Addressing computers in a cascadeTo connect units in cascade Connecting MC5 units in cascadeTips for successful cascading To test a specific link Using cascaded computersTesting specific links to cascaded computers Slave monitor Master monitor Multiple video head connectionsSlave MC5 Master MC5Overall initial configuration ConfigurationHotkeys Configuration menusTo access the configuration menu local and remote users To access the configuration menu global usersTo set an Admin password General security and configuration stepsConfiguration menus layout To enable general securityCross markers indicate which Access to all computers Press Access to no computers PressRegistering users edit user list To create/edit user accountsTo create/edit computer entries Tips when creating/editing computer entriesRegistering computers edit computer list Video compensation See Remote user skew adjustment for detailsCurrently selected cable length Computer video compensationTo apply computer video compensation Compensation will not be appliedIf the image controls cannot provide a crisp image Remote user video compensationTo display a suitable high contrast image To apply remote user video compensationCreating a skew test pattern Remote user skew adjustmentTo use skew adjustment Using the supplied skew patternConfiguration mode and permanently save all settings To define an autoscan list To select an autoscan modeAutoscanning To select an autoscan periodPreparations for configuration save/load Saving and restoring configuration settingsTo reset the MC5-IP models What to do if the Admin password has been forgottenTo reset MC5 models Recognising an IntelliMouse-style mouse Which restore setting do I use?To restore mouse operation when hot plugging Hot plugging and mouse restorationTo configure IP-specific settings Initial IP configurationTo use the initial IP-configuration sequence To configure IP details from a global user location IP configuration by global userViewer encryption settings Encryption settingsMC5-IP encryption settings    Networking issuesPositioning the MC5-IP in the network Firewall/router address Port settingsPlacing the MC5-IP behind a router or firewall AddressingDNS addressing To discover a DHCP-allocated IP addressPorts Placing the MC5-IP alongside the firewallEnsuring sufficient security To control two or more ports simultaneously Power switching configurationPower control sequences To configure the power sequences for each host computerKvmadmin -setusers users.csv Kvmadmin utilityKvmadmin command ip address parameters Kvmadmin -getconfig kvm1.cfgTo use the KVM Firmware Uploader utility Performing upgradesItems required to use the upgrade utility Upgrading MC5 models and CAMsCommence the upgrade Select the items to be upgradedSelect the upgrade file to be used Where Vxxx is the upgrade file version numberUpgrading MC5-IP models To upgrade MC5-IP modelsMC5-IP models Accessing the MC5Front panel controls MC5 modelsSelecting a computer Local and remote user accessTo gain access as a local or remote user To select a computer using the front panel controlsKeep Pressed down until all other Numbers have been entered To select a computer using hotkeysStandard hotkeys Above or for even longer cascaded computersTo select a computer using mouse buttons Advanced method To select a computer using the on-screen menuTo select a computer using mouse buttons Confirmation box Logging in and outSelecting cascaded computers Routing status To change banner colours or disable the bannerTo use the Routing status feature Reminder bannerUser preferences and functions Power switching via configuration menuTo switch a computer on or off Global user access Enter the MC5 address here and click OK Global user access via VNC viewerTo access via the VNC viewer To download the VNC viewer 1 Open your Web browserTo access via your web browser Global user access via web browserMenu bar Using the viewer windowWhen using the viewer window To select a host ConfigureMouse pointers Re-synchronise mouse Access mode shared/privatePower switching via viewer Auto calibrateResync Mouse Single Mouse ModeControls Mouse ControlKeyboard Control Info KVM switch menuWhen entering codes Video SettingsSetting the Threshold manually Using automatic configurationsIncreased by 50% when a slow link is detected Detect such noise and adjust the threshold accordinglyTo enter a port number in a Web browser Access via dial up modem or Isdn linkIf you need to enter a port number To initiate a dial up linkLinux Viewer encryption settingsSupported web browsers WindowsGetting assistance TroubleshootingTo access the configuration menus Appendix 1 Configuration menusFunctions User Preferences Screen Saver Mouse SwitchingAutoscan Mode Global PreferencesMouse Type User TimeoutOSD Dwell Time RS232 Mouse TypeExclusive Use Setup OptionsKeypads Controls LanguageAutomatic Logout DDC Options DDC Source Settings AUTO, LOCAL, DefaultDDC Refresh Settings AT START, Disabled Advanced OptionsTime and Date Configure IP portUnit Configuration Unit NameNetwork Configuration Reset Configuration Modem ConfigurationTo clear IP access control Clearing IP access controlWhat is IP access control? Main configuration Logged on users Appendix 2 Configuration pages via viewerTo access the remote configuration pages User accounts Firmware Version Unit configurationAdmin Password Hardware VersionAdvanced unit configuration Time & date configuration IP Network Mask Network configurationIP Access Control MAC addressTo edit/remove access control entries Setting IP access controlTo define a new IP access control entry To reorder access control entriesModem port Serial port configurationPower control port To create a new host entry Host configurationErase Host Configuration Add entry for unrecognised hostExamples Port/host addressing using Port DirectPort Direct For further details To get here Logging and statusTo copy and paste the log Syslog Server IP AddressPreferred encoding Click here to access the optionsColour/Encoding Auto selectCustomise Enable all inputsDisable all inputs view-only mode InputsMisc ScalingLoad / Save Defaults ReloadDefaults Save IdentitiesAppendix 4 VNC viewer window options Security Appendix 5 Browser viewer optionsEncoding and colour level Net masks Appendix 6 Addresses, masks and portsIP addresses Binary octet after Net masks the binary explanationInside a bit-wise and function Binary equivalentAddress ranges Calculating the mask for IP access controlSingle locations All locationsRouter/firewall address Security issues with portsPorts 9pin D-type Female Power switch to power switch daisy chain cableRS232 serial flash upgrade cable 6pin mini-DIN FemaleSLAVE2 end 9pin D-type male Multi-head synchronisation cableCreating macro sequences Appendix 8 Hotkey sequence codesPermissible key presses Appendix 9 Supported video modes General Public License Linux WarrantySafety information Safety considerations when using power switches with MC5End user licence agreement FCC Compliance Statement United States Radio Frequency EnergyEuropean EMC directive 89/336/EEC Germany France Italia USAIndex 109 110

MC5-IP specifications

The Lindy MC5-IP is an innovative and versatile presentation switcher designed for a variety of audiovisual settings, making it ideal for professional environments such as conferences, classrooms, and event spaces. Its primary objective is to provide seamless connectivity and efficient management of multiple video sources, enhancing the overall user experience in presentations and broadcasts.

One of the standout features of the MC5-IP is its capability to handle multiple input formats. It supports HDMI, DisplayPort, and VGA connections, allowing users to easily switch between various devices such as laptops, projectors, and media players. This flexibility promotes a smooth transition during presentations, minimizing downtime and interruptions.

The device is equipped with cutting-edge video processing technology, which ensures high-quality output at resolutions up to 4K. This high definition support is crucial in today’s digital landscape, as it provides crystal-clear images and vibrant colors, essential for impactful presentations. Furthermore, the MC5-IP employs advanced scaling technology that adjusts the output resolution to match the capabilities of the connected display, ensuring optimal visual quality.

Integration capabilities are another highlight of the MC5-IP. It can be easily integrated into existing AV systems and works seamlessly with popular control systems, such as Crestron and AMX. This compatibility allows for centralized control, making it easier for operators to manage video sources, adjust settings, and coordinate multiple displays without the need for complex setups.

In addition, the Lindy MC5-IP features an intuitive user interface that simplifies operation. The device can be controlled via a touch screen, remote control, or web-based application, providing users with convenient options to manage their presentations. The user-friendly design minimizes the learning curve, making it accessible for individuals who may not be tech-savvy.

The MC5-IP also prioritizes reliability and durability. It is built with high-quality components that ensure long-term performance, making it a dependable choice for frequently used environments. Finally, its compact form factor allows for easy transport and installation, catering to the dynamic needs of modern presentation scenarios.

In summary, the Lindy MC5-IP is a robust presentation switcher designed with professionalism in mind. Its versatility, high-resolution support, integration options, user-friendly interface, and durability make it an essential tool for anyone looking to enhance their AV presentations.