Lindy MC5-IP Remote user skew adjustment, To use skew adjustment, Using the supplied skew pattern

Page 31
Convergence test pattern showing the RGB crosses. In this case, the green signal can be seen out of line with the other two colours.
1 2 3 4 5 6 7 8

Remote user skew adjustment

The category 5, 5e and 6 cabling supported by the MC5 consists of four pairs of wires per cable. Three of these pairs are used to convey red, green and blue video signals to the remote video monitor. Due to the slight difference in twist rate between these three pairs, the red, green

and blue video signals may not arrive at precisely the same time. This is visible as

separate colour shadows on high contrast screen images and is particularly apparent when using higher screen resolutions and some types of category 5e cables.

To alleviate this situation, the User Station

8

8

Data signal

C5 Pro module provides internal skew

7

7

 

adjustment that can help to rectify the

6

6

Red

situation. The skew adjustment works

3

3

video signal

 

 

 

by delaying or advancing the timing

5

5

Green

of any of the red, green or blue colour

4

4

video signal

2

2

Blue

signals so that they are all delivered to

1

1

video signal

the monitor at precisely the same time.

For best results, the “skew” program supplied on the disk is the most accurate way of setting skew as the red, green and blue lines are rendered exactly on the screen as single pixel wide lines. The skew.bmp test pattern can also be used but it is less accurate. Alternatively, you can create your own skew pattern using a standard image creation package, as detailed opposite.

To use skew adjustment

1Display a skew pattern on the appropriate computer. You can either use the supplied skew pattern or create your own:

Using the supplied skew pattern

i Insert the supplied Installation CD-ROM into the CD player of the computer.

iiWithin Windows, use the My Computer option (usually available as a desktop icon or within the Start menu) to view the contents of the CD-ROM. Double-click the Skew entry to display the standard test pattern. If necessary, maximise the

application window so that the image fills the screen.

The screen will show a series of fine red, green and blue crosses which should all be in line, vertically and horizontally. Skew

affects the horizontal placement of the colours and using this pattern it is much easier to discover which, if any, colours are being adversely affected by the cable link.

Creating a skew test pattern

iRun any image creation/editing application, such as the Paint program supplied with Windows.

iiUsing the image application create three stacked horizontal rectangles (one red, one green and one blue) that fill the width of the screen.

iiiDraw a vertical black line down across the coloured bars and then repeat this vertical line at intervals along the width of the coloured bars. These lines create breaks across the colours and give you more opportunities to view the horizontal position of each colour relative to the others.

2On the remote user keyboard (connected to a User Station C5 Pro),

simultaneously, press the hotkeys (by default, and ) along with to enter configuration mode.

The three keyboard indicators (‘Num Lock’, ‘Caps Lock’ and ‘Scroll Lock’) will now begin to flash in sequence.

   



30

Image 31
Contents  MC5-IP KVM SwitchContents Further information Index CAM formats Local user One user can be connected directly to the MC5  Many computersFront panel buttons MC5 features front and rearIndicators Power control port Upgrade port Modem port IP models onlySwitc What’s in the box What you may additionally needRack brackets Mounting   ConnectionsTo connect the local user port Local userMC5 rear panel Cable lengths for remote user locations Remote user via User StationTo connect a remote user To connect the Global user IP network port Global user IP network portIP network link To connect a computer system Access ModuleCategory 5, 5e or Cable from CAM To connect a modem or Isdn adapter Modem/ISDN portMC5 rear panel Cable from modem Or Isdn adapter To connect the power supply Power in connectionOutput lead from Power adapter To connect and address the switch boxes Power control portSee also Cascading multiple unitsCascade tree How cascade connections operate 43 41 Addressing computers in a cascadeTips for successful cascading Connecting MC5 units in cascadeTo connect units in cascade Testing specific links to cascaded computers Using cascaded computersTo test a specific link Slave monitor Master monitor Multiple video head connectionsSlave MC5 Master MC5Overall initial configuration ConfigurationHotkeys Configuration menusTo access the configuration menu local and remote users To access the configuration menu global usersTo set an Admin password General security and configuration stepsConfiguration menus layout To enable general securityCross markers indicate which Access to all computers Press Access to no computers PressRegistering users edit user list To create/edit user accountsRegistering computers edit computer list Tips when creating/editing computer entriesTo create/edit computer entries Video compensation See Remote user skew adjustment for detailsCurrently selected cable length Computer video compensationTo apply computer video compensation Compensation will not be appliedIf the image controls cannot provide a crisp image Remote user video compensationTo display a suitable high contrast image To apply remote user video compensationCreating a skew test pattern Remote user skew adjustmentTo use skew adjustment Using the supplied skew patternConfiguration mode and permanently save all settings To define an autoscan list To select an autoscan modeAutoscanning To select an autoscan periodPreparations for configuration save/load Saving and restoring configuration settingsTo reset MC5 models What to do if the Admin password has been forgottenTo reset the MC5-IP models Recognising an IntelliMouse-style mouse Which restore setting do I use?To restore mouse operation when hot plugging Hot plugging and mouse restorationTo use the initial IP-configuration sequence Initial IP configurationTo configure IP-specific settings To configure IP details from a global user location IP configuration by global userMC5-IP encryption settings Encryption settingsViewer encryption settings Positioning the MC5-IP in the network Networking issues   Firewall/router address Port settingsPlacing the MC5-IP behind a router or firewall AddressingDNS addressing To discover a DHCP-allocated IP addressEnsuring sufficient security Placing the MC5-IP alongside the firewallPorts To control two or more ports simultaneously Power switching configurationPower control sequences To configure the power sequences for each host computerKvmadmin -setusers users.csv Kvmadmin utilityKvmadmin command ip address parameters Kvmadmin -getconfig kvm1.cfgTo use the KVM Firmware Uploader utility Performing upgradesItems required to use the upgrade utility Upgrading MC5 models and CAMsCommence the upgrade Select the items to be upgradedSelect the upgrade file to be used Where Vxxx is the upgrade file version numberUpgrading MC5-IP models To upgrade MC5-IP modelsMC5-IP models Accessing the MC5Front panel controls MC5 modelsSelecting a computer Local and remote user accessTo gain access as a local or remote user To select a computer using the front panel controlsKeep Pressed down until all other Numbers have been entered To select a computer using hotkeysStandard hotkeys Above or for even longer cascaded computersTo select a computer using mouse buttons To select a computer using the on-screen menuTo select a computer using mouse buttons Advanced method Selecting cascaded computers Logging in and outConfirmation box Routing status To change banner colours or disable the bannerTo use the Routing status feature Reminder bannerTo switch a computer on or off Power switching via configuration menuUser preferences and functions Global user access Enter the MC5 address here and click OK Global user access via VNC viewerTo access via the VNC viewer To download the VNC viewer 1 Open your Web browserTo access via your web browser Global user access via web browserWhen using the viewer window Using the viewer windowMenu bar Mouse pointers ConfigureTo select a host Re-synchronise mouse Access mode shared/privatePower switching via viewer Auto calibrateResync Mouse Single Mouse ModeControls Mouse ControlKeyboard Control Info KVM switch menuWhen entering codes Video SettingsSetting the Threshold manually Using automatic configurationsIncreased by 50% when a slow link is detected Detect such noise and adjust the threshold accordinglyTo enter a port number in a Web browser Access via dial up modem or Isdn linkIf you need to enter a port number To initiate a dial up linkLinux Viewer encryption settingsSupported web browsers WindowsGetting assistance TroubleshootingTo access the configuration menus Appendix 1 Configuration menusFunctions User Preferences Screen Saver Mouse SwitchingAutoscan Mode Global PreferencesMouse Type User TimeoutOSD Dwell Time RS232 Mouse TypeExclusive Use Setup OptionsKeypads Controls LanguageAutomatic Logout DDC Options DDC Source Settings AUTO, LOCAL, DefaultDDC Refresh Settings AT START, Disabled Advanced OptionsTime and Date Configure IP portUnit Configuration Unit NameNetwork Configuration Reset Configuration Modem ConfigurationWhat is IP access control? Clearing IP access controlTo clear IP access control To access the remote configuration pages Appendix 2 Configuration pages via viewerMain configuration Logged on users User accounts Firmware Version Unit configurationAdmin Password Hardware VersionAdvanced unit configuration Time & date configuration IP Network Mask Network configurationIP Access Control MAC addressTo edit/remove access control entries Setting IP access controlTo define a new IP access control entry To reorder access control entriesPower control port Serial port configurationModem port To create a new host entry Host configurationErase Host Configuration Add entry for unrecognised hostPort Direct Port/host addressing using Port DirectExamples For further details To get here Logging and statusTo copy and paste the log Syslog Server IP AddressPreferred encoding Click here to access the optionsColour/Encoding Auto selectCustomise Enable all inputsDisable all inputs view-only mode InputsMisc ScalingLoad / Save Defaults ReloadDefaults Save IdentitiesAppendix 4 VNC viewer window options Encoding and colour level Appendix 5 Browser viewer optionsSecurity IP addresses Appendix 6 Addresses, masks and portsNet masks Binary octet after Net masks the binary explanationInside a bit-wise and function Binary equivalentAddress ranges Calculating the mask for IP access controlSingle locations All locationsPorts Security issues with portsRouter/firewall address 9pin D-type Female Power switch to power switch daisy chain cableRS232 serial flash upgrade cable 6pin mini-DIN FemaleSLAVE2 end 9pin D-type male Multi-head synchronisation cablePermissible key presses Appendix 8 Hotkey sequence codesCreating macro sequences Appendix 9 Supported video modes General Public License Linux WarrantySafety information Safety considerations when using power switches with MC5End user licence agreement European EMC directive 89/336/EEC Radio Frequency EnergyFCC Compliance Statement United States Germany France Italia USAIndex 109 110

MC5-IP specifications

The Lindy MC5-IP is an innovative and versatile presentation switcher designed for a variety of audiovisual settings, making it ideal for professional environments such as conferences, classrooms, and event spaces. Its primary objective is to provide seamless connectivity and efficient management of multiple video sources, enhancing the overall user experience in presentations and broadcasts.

One of the standout features of the MC5-IP is its capability to handle multiple input formats. It supports HDMI, DisplayPort, and VGA connections, allowing users to easily switch between various devices such as laptops, projectors, and media players. This flexibility promotes a smooth transition during presentations, minimizing downtime and interruptions.

The device is equipped with cutting-edge video processing technology, which ensures high-quality output at resolutions up to 4K. This high definition support is crucial in today’s digital landscape, as it provides crystal-clear images and vibrant colors, essential for impactful presentations. Furthermore, the MC5-IP employs advanced scaling technology that adjusts the output resolution to match the capabilities of the connected display, ensuring optimal visual quality.

Integration capabilities are another highlight of the MC5-IP. It can be easily integrated into existing AV systems and works seamlessly with popular control systems, such as Crestron and AMX. This compatibility allows for centralized control, making it easier for operators to manage video sources, adjust settings, and coordinate multiple displays without the need for complex setups.

In addition, the Lindy MC5-IP features an intuitive user interface that simplifies operation. The device can be controlled via a touch screen, remote control, or web-based application, providing users with convenient options to manage their presentations. The user-friendly design minimizes the learning curve, making it accessible for individuals who may not be tech-savvy.

The MC5-IP also prioritizes reliability and durability. It is built with high-quality components that ensure long-term performance, making it a dependable choice for frequently used environments. Finally, its compact form factor allows for easy transport and installation, catering to the dynamic needs of modern presentation scenarios.

In summary, the Lindy MC5-IP is a robust presentation switcher designed with professionalism in mind. Its versatility, high-resolution support, integration options, user-friendly interface, and durability make it an essential tool for anyone looking to enhance their AV presentations.