Using the viewer window

The viewer window gives you the ability to view and control the MC5-IP and its host computer(s). Its operation is almost identical regardless of whether you used the VNC viewer or your Web browser to display it.

The menu bar

The viewer window presents a menu bar similar to that shown below. Certain items within the toolbar are displayed depending upon your access permissions and/or the MC5-IP configuration.

Viewer options

Ctrl Alt Del

Controls

Power

Dialogue area

(VNC viewer

Sends the

Displays a menu

Click to access

Indicates your username

only) Click the

Ctrl Alt Del

of options

the power

and the host system that

VNC icon to

sequence

concerning

on/off options

you are currently viewing.

view the viewer

to the

keyboard, video

for the current

This area can also display

window options.

current host

and mouse

host computer.

other messages.

 

 

 

computer.

operation.

 

 

 

 

 

 

 

 

 

Re-sync mouse

Auto calibrate

Hosts

Access mode

Configure

Ensures that the

Determines the

Click to

Allows you

This option is only

mouse pointer

optimum video and/or

display a list

to choose

available to the

which you move

mouse settings for the

of computers.

between

admin user and

and the mouse

currently selected host

Choose an

Shared and

provides access

pointer on the

computer. This button

entry to

Private access

to the main

host system

will flash red when

connect to

modes.

configuration

are correctly

a new host screen is

that host

 

menus.

synchronised.

encountered. Click this

computer.

 

 

 

button when you first

 

 

 

 

visit a new screen.

 

 

 

When using the viewer window

What is the best screen resolution to use?

The best resolution for your computer is one that is larger than the screen of the host computer that you are viewing. This will allow you to see everything without scrolling around. Alternatively, the VNC viewer can be set to scale the image to fit your screen, but remember that some pixel dithering effect will be seen when scaling is used.

How do I navigate around a larger screen?

If the screen that you are viewing has a larger resolution than your viewing window you will need to scroll around to see all items. The viewer window allows you to ‘bump scroll’ (only in full screen mode). This means that when your mouse cursor bumps against the edge of the screen, the screen image will scroll across automatically.

How do I escape from full screen mode?

Press the F8 button. This button is changeable but is most often set to F8.

Why is the button flashing red?

This happens when a new host screen is viewed (that has not been viewed before). Click the button to perform an auto calibration for the screen and the mouse. See Auto calibrate for important information about this feature.

How do I change between host computers?

The best way to change between host computers is to click the ‘Hosts’ button and then select the required computer by name. See Host selection.

How do I remove traces of moved items from the screen?

When you move an item or window across the screen, sometimes it can leave unsightly trails. These are called artifacts and can be particularly prevalent when the connection speed is low. To remove artifacts, click the ‘Controls’ button and select the ‘Refresh screen’ option. See Controls.

How do I make the most of a slow connection?

The VNC viewer is slightly better suited to slower connections than the browser viewer because it offers more options. Click the Options button of the VNC viewer when entering the MC5-IP address during log on.

Adjust the Threshold setting

Ensure that the video Threshold setting is set higher than the automatic setting suggests. Tweak this setting manually to ensure the best setting.

Fewer colours

Select the Low (64 colours) mode. The Very low option offers hardly any improvement and looks a lot worse.

Rate limit mouse events

When selected, this mode greatly reduces the mouse movement data that are sent to the host computer. When you move the local mouse, the remote cursor will catch up roughly once per second.

   



58

Image 59
Contents  MC5-IP KVM SwitchContents Further information Index CAM formats Local user One user can be connected directly to the MC5  Many computersFront panel buttons MC5 features front and rearIndicators Power control port Upgrade port Modem port IP models onlySwitc What’s in the box What you may additionally needRack brackets Mounting   ConnectionsMC5 rear panel Local userTo connect the local user port To connect a remote user Remote user via User StationCable lengths for remote user locations IP network link Global user IP network portTo connect the Global user IP network port Category 5, 5e or Cable from CAM Access ModuleTo connect a computer system MC5 rear panel Cable from modem Or Isdn adapter Modem/ISDN portTo connect a modem or Isdn adapter Output lead from Power adapter Power in connectionTo connect the power supply To connect and address the switch boxes Power control portCascade tree Cascading multiple unitsSee also How cascade connections operate 43 41 Addressing computers in a cascadeTo connect units in cascade Connecting MC5 units in cascadeTips for successful cascading To test a specific link Using cascaded computersTesting specific links to cascaded computers Slave monitor Master monitor Multiple video head connectionsSlave MC5 Master MC5Overall initial configuration ConfigurationHotkeys Configuration menusTo access the configuration menu local and remote users To access the configuration menu global usersTo set an Admin password General security and configuration stepsConfiguration menus layout To enable general securityCross markers indicate which Access to all computers Press Access to no computers PressRegistering users edit user list To create/edit user accountsTo create/edit computer entries Tips when creating/editing computer entriesRegistering computers edit computer list Video compensation See Remote user skew adjustment for detailsCurrently selected cable length Computer video compensationTo apply computer video compensation Compensation will not be appliedIf the image controls cannot provide a crisp image Remote user video compensationTo display a suitable high contrast image To apply remote user video compensationCreating a skew test pattern Remote user skew adjustmentTo use skew adjustment Using the supplied skew patternConfiguration mode and permanently save all settings To define an autoscan list To select an autoscan modeAutoscanning To select an autoscan periodPreparations for configuration save/load Saving and restoring configuration settingsTo reset the MC5-IP models What to do if the Admin password has been forgottenTo reset MC5 models Recognising an IntelliMouse-style mouse Which restore setting do I use?To restore mouse operation when hot plugging Hot plugging and mouse restorationTo configure IP-specific settings Initial IP configurationTo use the initial IP-configuration sequence To configure IP details from a global user location IP configuration by global userViewer encryption settings Encryption settingsMC5-IP encryption settings    Networking issuesPositioning the MC5-IP in the network Firewall/router address Port settingsPlacing the MC5-IP behind a router or firewall AddressingDNS addressing To discover a DHCP-allocated IP addressPorts Placing the MC5-IP alongside the firewallEnsuring sufficient security To control two or more ports simultaneously Power switching configurationPower control sequences To configure the power sequences for each host computerKvmadmin -setusers users.csv Kvmadmin utilityKvmadmin command ip address parameters Kvmadmin -getconfig kvm1.cfgTo use the KVM Firmware Uploader utility Performing upgradesItems required to use the upgrade utility Upgrading MC5 models and CAMsCommence the upgrade Select the items to be upgradedSelect the upgrade file to be used Where Vxxx is the upgrade file version numberUpgrading MC5-IP models To upgrade MC5-IP modelsMC5-IP models Accessing the MC5Front panel controls MC5 modelsSelecting a computer Local and remote user accessTo gain access as a local or remote user To select a computer using the front panel controlsKeep Pressed down until all other Numbers have been entered To select a computer using hotkeysStandard hotkeys Above or for even longer cascaded computersTo select a computer using mouse buttons Advanced method To select a computer using the on-screen menuTo select a computer using mouse buttons Confirmation box Logging in and outSelecting cascaded computers Routing status To change banner colours or disable the bannerTo use the Routing status feature Reminder bannerUser preferences and functions Power switching via configuration menuTo switch a computer on or off Global user access Enter the MC5 address here and click OK Global user access via VNC viewerTo access via the VNC viewer To download the VNC viewer 1 Open your Web browserTo access via your web browser Global user access via web browserMenu bar Using the viewer windowWhen using the viewer window To select a host ConfigureMouse pointers Re-synchronise mouse Access mode shared/privatePower switching via viewer Auto calibrateResync Mouse Single Mouse ModeControls Mouse ControlKeyboard Control Info KVM switch menuWhen entering codes Video SettingsSetting the Threshold manually Using automatic configurationsIncreased by 50% when a slow link is detected Detect such noise and adjust the threshold accordinglyTo enter a port number in a Web browser Access via dial up modem or Isdn linkIf you need to enter a port number To initiate a dial up linkLinux Viewer encryption settingsSupported web browsers WindowsGetting assistance TroubleshootingTo access the configuration menus Appendix 1 Configuration menusFunctions User Preferences Screen Saver Mouse SwitchingAutoscan Mode Global PreferencesMouse Type User TimeoutOSD Dwell Time RS232 Mouse TypeExclusive Use Setup OptionsKeypads Controls LanguageAutomatic Logout DDC Options DDC Source Settings AUTO, LOCAL, DefaultDDC Refresh Settings AT START, Disabled Advanced OptionsTime and Date Configure IP portUnit Configuration Unit NameNetwork Configuration Reset Configuration Modem ConfigurationTo clear IP access control Clearing IP access controlWhat is IP access control? Main configuration Logged on users Appendix 2 Configuration pages via viewerTo access the remote configuration pages User accounts Firmware Version Unit configurationAdmin Password Hardware VersionAdvanced unit configuration Time & date configuration IP Network Mask Network configurationIP Access Control MAC addressTo edit/remove access control entries Setting IP access controlTo define a new IP access control entry To reorder access control entriesModem port Serial port configurationPower control port To create a new host entry Host configurationErase Host Configuration Add entry for unrecognised hostExamples Port/host addressing using Port DirectPort Direct For further details To get here Logging and statusTo copy and paste the log Syslog Server IP AddressPreferred encoding Click here to access the optionsColour/Encoding Auto selectCustomise Enable all inputsDisable all inputs view-only mode InputsMisc ScalingLoad / Save Defaults ReloadDefaults Save IdentitiesAppendix 4 VNC viewer window options Security Appendix 5 Browser viewer optionsEncoding and colour level Net masks Appendix 6 Addresses, masks and portsIP addresses Binary octet after Net masks the binary explanationInside a bit-wise and function Binary equivalentAddress ranges Calculating the mask for IP access controlSingle locations All locationsRouter/firewall address Security issues with portsPorts 9pin D-type Female Power switch to power switch daisy chain cableRS232 serial flash upgrade cable 6pin mini-DIN FemaleSLAVE2 end 9pin D-type male Multi-head synchronisation cableCreating macro sequences Appendix 8 Hotkey sequence codesPermissible key presses Appendix 9 Supported video modes General Public License Linux WarrantySafety information Safety considerations when using power switches with MC5End user licence agreement FCC Compliance Statement United States Radio Frequency EnergyEuropean EMC directive 89/336/EEC Germany France Italia USAIndex 109 110

MC5-IP specifications

The Lindy MC5-IP is an innovative and versatile presentation switcher designed for a variety of audiovisual settings, making it ideal for professional environments such as conferences, classrooms, and event spaces. Its primary objective is to provide seamless connectivity and efficient management of multiple video sources, enhancing the overall user experience in presentations and broadcasts.

One of the standout features of the MC5-IP is its capability to handle multiple input formats. It supports HDMI, DisplayPort, and VGA connections, allowing users to easily switch between various devices such as laptops, projectors, and media players. This flexibility promotes a smooth transition during presentations, minimizing downtime and interruptions.

The device is equipped with cutting-edge video processing technology, which ensures high-quality output at resolutions up to 4K. This high definition support is crucial in today’s digital landscape, as it provides crystal-clear images and vibrant colors, essential for impactful presentations. Furthermore, the MC5-IP employs advanced scaling technology that adjusts the output resolution to match the capabilities of the connected display, ensuring optimal visual quality.

Integration capabilities are another highlight of the MC5-IP. It can be easily integrated into existing AV systems and works seamlessly with popular control systems, such as Crestron and AMX. This compatibility allows for centralized control, making it easier for operators to manage video sources, adjust settings, and coordinate multiple displays without the need for complex setups.

In addition, the Lindy MC5-IP features an intuitive user interface that simplifies operation. The device can be controlled via a touch screen, remote control, or web-based application, providing users with convenient options to manage their presentations. The user-friendly design minimizes the learning curve, making it accessible for individuals who may not be tech-savvy.

The MC5-IP also prioritizes reliability and durability. It is built with high-quality components that ensure long-term performance, making it a dependable choice for frequently used environments. Finally, its compact form factor allows for easy transport and installation, catering to the dynamic needs of modern presentation scenarios.

In summary, the Lindy MC5-IP is a robust presentation switcher designed with professionalism in mind. Its versatility, high-resolution support, integration options, user-friendly interface, and durability make it an essential tool for anyone looking to enhance their AV presentations.