Peavey CS 1800G manual Important Safety Instructions

Page 31

IMPORTANT SAFETY INSTRUCTIONS

WARNING: When using electric products, basic cautions should always be followed, including the following.

1.Read all safety and operating instructions before using this product.

2.All safety and operating instructions should be retained for future reference.

3.Obey all cautions in the operating instructions and on the back of the unit.

4.All operating instructions should be followed.

5.This product should not be used near water, i.e., a bathtub, sink, swimming pool, wet basement, etc.

6.This product should be located so that its position does not interfere with its proper ventilation. It should not be placed flat against a wall or placed in a built-in enclosure that will impede the flow of cooling air.

7.This product should not be placed near a source of heat such as a stove, radiator, or another heat producing amplifier.

8.Connect only to a power supply of the type marked on the unit adjacent to the power supply cord.

9.Never break off the ground pin on the power supply cord. For more information on grounding, write for our free booklet “Shock Hazard and Grounding.”

10.Power supply cords should always be handled carefully. Never walk or place equipment on power supply cords. Periodically check cords for cuts or signs of stress, especially at the plug and the point where the cord exits the unit.

1 1. The power supply cord should be unplugged when the unit is to be unused for long periods of time.

12.If this product is to be mounted in an equipment rack, rear support should be provided.

13.Metal parts can be cleaned with a damp rag. The vinyl covering used on some units can be cleaned with a damp rag or an ammonia- based household cleaner if necessary. Disconnect unit from power supply before cleaning.

14.Care should be taken so that objects do not fall and liquids are not spilled into the unit through the ventilation holes or any other openings.

15.This unit should be checked by a qualified service technician if:

a.The power supply cord or plug has been damaged.

b.Anything has fallen or been spilled into the unit.

c.The unit does not operate correctly.

d.The unit has been dropped or the enclosure damaged.

16.The user should not attempt to service this equipment. All service work should be done by a qualified service technician.

17.This product should be used only with a cart or stand that is recommended by Peavey Electronics.

18.Exposure to extremely high noise levels may cause a permanent hearing loss. Individuals vary considerably in susceptibility to noise

induced hearing loss, but nearly everyone will lose some hearing if exposed to sufficiently intense noise for a sufficient time. The U.S. Government’s Occupational Safety and Health Administration (OSHA) has specified the following permissible noise level

exposures.

Duration Per Day In Hours

Sound Level dBA, Slow Response

8

90

6

92

4

95

 

97

2

100

1 l/2

102

1

105

l/2

110

l/4 or less

115

According to OSHA, any exposure in excess of the above permissible limits could result in some hearing loss.

Ear plugs or protectors in the ear canals or over the ears must be worn when operating this amplification system in order to prevent a permanent hearing loss if exposure is in excess of the limits as set forth above. To ensure against potentially dangerous exposure to high sound pressure levels, it is recommended that all persons exposed to equipment capable of producing high sound pressure levels such as this amplification system be protected by hearing protectors while this unit is in operation.

SAVE THESE INSTRUCTIONS!

31

Image 31
Contents Page Page Cstm 1800G Features Ddttm Active LED Front Panel Features Channels a & B Input SensitivityPower LED Power SwitchBack Panel Back Panel FeaturesMains Power Source 6 120 V products only Ground Lift SwitchLOW-Z Input PL-2 Selector SwitchMode Switch Ddttm Compression SwitchIndustrial and Commercial Installations Installation and ConnectionBridge Mode Ddttm Compression Power Consumption Output Power typical valueRated Output Power Power Bandwidth typical valueCstm 1800G Flow Diagram Wiring Diagrams Page Funciones DE Tablero Frontal Canales a Y B Tablero Trasero Ground Lift Switch Interruptor levantamiento de tierraFunciones DEL Tablero Trasero LOW-Z Input Entrada de baja impedancia PL-2 Selector Switch Interruptor selector PL-2Mode Switch Interruptor de modo Speaker Outputs Salidas de altavocesINSTALACI6N Industrial Y Comercial Ddttm Compression Switch Interruptor de la compresih DdttmHIGH-Z Input Jacks Encbufes de entrada de alta impedancia INSTALACIdN Y CONEXI6NCOMPRESI6N Ddttm MOD0 DE PuentePage Canaux a ET B Speaker Outputs Sorties des baut-parleurs Ground Lift Switch Commutateur de sCparation de terreLOW-Z Input EntrCe Low-Z PL-2 Selector Switch Commutateur de sClection PL-2Mode Switch Commutateur de mode Ddttm Compression Switch Commutateur de compression DdttmInstallation Commerciale ET Industrielle Installation ET ConnexionMode Pont Compression Ddttm Cstm 1800G Features Beschreibung DER Frontplatte Kanal a UND B Speaker Outputs Lautsprecherausggnge Ground Lift Switch ErdabhebungsschalterLOW-Z Input Niederohmiger eingang Transformer Receptacle Transformatorbuchse PL-2 Selector Switch PL-2 WahlschalterMode Switch Modusschalter Ddttm Compression Switch DDTTM-KompressionsschalterAufstellung UND Anschluss DDTTM-KOMPRFSSIONJ Peavey ONE-YEAR Limited WARRANTY/REMEDY Important Safety Instructions =!!I~EK

CS 1800G specifications

The Peavey CS 1800G is a powerful and versatile professional power amplifier that is well-suited for a wide range of audio applications. Known for its robust construction and high-quality sound output, the CS 1800G stands out in the Peavey lineup, making it an ideal choice for touring musicians, DJs, and audio engineers alike.

One of the main features of the CS 1800G is its impressive power output, delivering 900 watts per channel at 4 ohms in stereo mode, and up to 1800 watts in bridged mono mode. This substantial power ensures that the amplifier can drive even the most demanding speakers while providing clear and dynamic sound reproduction across various performance settings.

The CS 1800G incorporates Peavey's proprietary TransTube technology, which enhances the amplifier's ability to provide warm, tube-like tones. This feature has been engineered to deliver a richer tonal character compared to many traditional solid-state amplifiers, giving performers and sound engineers more flexibility in crafting their sound.

In terms of its technical design, the CS 1800G comes equipped with advanced protection circuitry, ensuring the amplifier remains safe from overheating, short circuits, and other potential hazards that could affect performance. Additionally, the unit features comprehensive LED indicators that provide essential feedback on performance status, including signal presence and clip indicators.

The amplifier’s rear panel offers a variety of connectivity options, including balanced XLR and ¼-inch inputs, as well as Speakon and binding post outputs. This flexibility allows for easy integration into any audio system, making it suitable for both live sound applications and installation environments.

Weighing in at 22.4 pounds, the CS 1800G strikes a balance between portability and power, making it manageable for transport without compromising on performance quality. This durable build is complemented by a rugged metal chassis, designed to withstand the rigors of touring and professional use.

Overall, the Peavey CS 1800G is a reliable and powerful amplifier that combines cutting-edge technology, robust performance, and user-friendly features, making it a top choice for anyone in search of high-quality audio amplification. Whether for concerts, events, or permanent installations, the CS 1800G delivers the performance and flexibility needed for diverse audio needs.