Delta SLC-500, PLC-5, 1770-KF2 user manual DeviceDataType

Page 9

Powerful Solutions for Digital Plants

Attribute

 

 

Defined Values

 

 

DeviceDataType

0 = Basic Protected

 

1

= Basic Protected Bit

 

2

= Basic Unprotected

 

3

= Basic Unprotected Bit

 

4

= PLC-5 Typed (Logical ASCII Addressing)

 

5

= PLC-5 Ranged (Logical ASCII Addressing)

 

6

= Diagnostic

 

7

= PLC-5 Read-Mod-Write (Logical ASCII Addressing)

 

8

=

PLC-5 Typed (Logical Binary Addressing)

 

9

=

PLC-5 Ranged (Logical Binary Addressing)

 

10 = PLC-5 Read-Mod-Write (Logical Binary Addressing)

 

11= SLC 500, SLC 5/03 and SLC 5/04 Protected Typed

 

Logical Read/Write with three address fields

 

12=SLC Reserved

 

13=PLC-3

 

 

SpecialData1

This Field is “Don’t Care” for DeviceDataType 0-3, and 6

(PLC-5 /SLC / PLC-3 File Type)

0 = Output File Type, O

 

1

= Input File Type, I

 

2

= Status File Type, S

 

3

= Binary File Type, B

 

4

= Timer File Type, T *

 

5

= Counter File Type, C *

For PLC-3 Character value of File Prefix. For

6

= Control File Type, R *

 

 

 

example for File F, enter 70.

7= Integer File Type, N

 

8

= Floating File Type, F

 

* Timer, Counter and Control types are not available in this

 

driver at this time when communicating with a PLC-5.

 

 

SpecialData2

This field is “Don’t Care” for DeviceDataType 0-3, 6

(PLC-5 / SLC / PLC-3 File Number)

0 – 65535 file number

 

0

- 8 are reserved to match with file types in

 

SpecialData1

 

 

 

 

MYNAH Technologies ￿ 504 Trade Center Blvd. ￿ Chesterfield, MO 63005 ￿ Telephone 636 681-1555 ￿ Fax 636 681-1660

www.mynah.com

8

Image 9
Contents May Rev. P1.7 Scope IntroductionDocument Format System SpecificationsFirmware Protocol Compatibility Software Requirements Related DocumentsTheory of Operation Powerful Solutions for Digital Plants Downloading the firmware Channel Attributes Block of Psic Configuration InformationDeviceDataType SpecialData4 Device And Dataset ConfigurationDeviceDataType Types 0 3 Basic Commands Powerful Solutions for Digital Plants Powerful Solutions for Digital Plants Dataset Configuration Display Powerful Solutions for Digital Plants Powerful Solutions for Digital Plants Serial Port Configuration for DeltaV Psic Verify Configuration Verify Hardware and Software Version NumberVerify I/O Communication With Control Studio LED Indication Using DiagnosticsDeltaV PLC/SLC Electrical Interface Port 1 Half Duplex Data+/Full GND TXD RXD DTR DSR DCD RTS CTS Wiring Connections for RS-232 CommunicationsGND TXD RXD DTR DSR RTS CTS KE Module Series B Switch Settings KE Module Series a Switch Settings1770-KF2 Module Switch Settings