Dukane 28A8711 user manual Regarding the Indicator Lamps, Power Lamp Temp

Page 49

Regarding the Indicator Lamps

Lighting and flashing of the POWER indicator, the LAMP indicator, and the TEMP indicator have the meanings as described in the Table below. Please respond in accordance with the instructions within the Table.

POWER

LAMP

TEMP

Description

indicator

indicator

indicator

 

 

 

 

 

The orange

Turned OFF

Turned OFF

The STANDBY mode is set

lamp is lighted

(Not lighted)

(Not lighted)

 

 

 

 

 

Flashing of the green lamp

Turned OFF

Turned OFF

The unit is warming up. Please wait.

 

 

 

 

The green lamp is lighted

Turned OFF

Turned OFF

The unit is in an ON state. Ordinary operations may be performed.

 

 

 

 

Flashing of the orange lamp

Turned OFF

Turned OFF

The unit is cooling down. Please wait.

 

 

 

 

 

 

 

The unit is cooling down. Please wait.

Blinking of the

-

-

A certain error has been detected. Wait until the POWER indicator lamp has finished

red lamp

flashing, and then perform the proper response measure using the item descriptions

 

 

 

 

 

below as reference.

 

 

 

 

 

 

 

The lamp does not light.

The red lamp

The red lamp

Turned

There is a possibility that the interior portion has become heated. Turn the power OFF and wait

is lighted, or

approximately 20 minutes. After the main unit has cooled down, please confirm whether or not

is lighted

OFF

there is blockage of the air passage aperture, whether or not the filter is dirty, and/or whether or

blinks

 

 

not the peripheral temperature exceeds 35°C, etc. After performing any needed maintenance,

 

 

 

turn the power ON again; if the same display is displayed, then please change the lamp.

 

 

 

 

The red lamp

 

 

Either there is no lamp and/or lamp cover, or either of these has not been properly fixed

Blinking of the

Turned

(attached). Turn the power OFF and wait approximately 45 minutes. After the main unit has

is lighted, or

sufficiently cooled down, please make confirmation of the attachment state of the lamp and

red lamp

OFF

blinks

lamp cover. After performing any needed maintenance, turn the power ON again; if the same

 

 

 

 

 

display is displayed, then please contact a sales store or a service company.

 

 

 

 

The red lamp

Turned

Blinking of the

The cooling fan is not operating. Turn the power OFF and wait approximately 20 minutes. After the

is lighted, or

main unit has cooled down, please make confirmation that no foreign matter has become caught in

OFF

red lamp

the fan, etc. After performing any needed maintenance, turn the power ON again; if the same display

blinks

 

 

is displayed, then please contact a sales store or a service company.

 

 

 

 

 

 

 

There is a possibility that the interior portion has become heated. Turn the power OFF and wait

The red lamp is

Turned

The red lamp is

approximately 20 minutes. After the main unit has cooled down, please confirm whether or not

lighted, or

there is blockage of the air passage aperture, whether or not the filter is dirty, and/or whether or

OFF

lighted

not the peripheral temperature exceeds 35°C, etc. After performing any needed maintenance,

blinks

 

 

turn the power ON again; if the same display is displayed, then please contact a sales store or a

 

 

 

service company.

The green lamp

Alternative blinking

There is a possibility that the interior portion has become overcooled. Please use the unit within

the usage temperature parameters (0°C to 35°C). After performing any needed maintenance,

is lighted

with the red lamp

turn the power ON again; if the same display is displayed, then please contact a sales store or a

 

 

 

service company.

The green

Simultaneous blinking

This is a notification that it is time to clean the filter.

After cleaning the filter, operate the FILTER TIME portion of the OPTION Menu, and perform

lamp is lighted

with the red lamp

reset of the FILTER TIME.

 

 

 

 

 

 

 

NOTE

When the interior portion has become overheated, for safety purposes, the power source is automatically turned OFF, and the indicator lamps may also be turned OFF. Press the “ ” (power OFF) side of the main power switch, and wait for approximately 20 minutes. Please then use the unit only after having first confirmed that the unit has sufficiently cooled down.

9

Image 49
Contents Model 28A8711 Page Page Page Page Page Page Page Contents Power cord Projector FeaturesControl AdapterDevices you will be using to the projector Only use the power cord that came with the projectorPart Names Remote Control Adjusting the Projectors Elevator Feet Setting UP the ProjectorPress and hold in the elevator Buttons Turn the elevator screw to fine tuneScreen Adjusting the Screen Size and Projection DistanceConnecting Your Devices Function Projector Port Connection Cables Ports and CablesConnecting to a Computer Connecting Your DevicesA a a BNC Input DVI InputConnecting to a VCR Connecting to a DVD PlayerConnecting to a Display Monitor Putting batteries into the remote control unit Using the Remote ControlRemove the battery cover Close the battery coverRemote control in an area free from obstacles Operating the remote controlMeters with a 40-degree range Turning on the Power Selecting an Input Signal Turning OFF the Power Press the Volume button Adjusting the VolumeUse the lever switch / to adjust the volume Temporarily Muting the SoundUse the , , , buttons to adjust the position Adjusting the PositionPress the Position button Automatic Adjustment for RGB Input Using the Automatic Adjustment FeatureAutomatic Adjustment for Video Input Press the Auto buttonPress the Keystone button Correcting Keystone DistortionsAs illustrated on the right, a dialog will appear On the screen to aid you in correcting the distortionFreezing the Screen Using the Magnify FeatureWas begun When BNC RGB is selected Adjusting Screen with ONE-TOUCHPress the ONE Touch button You can activate the following functions just byTemporarily Blanking the Screen Selecting the Aspect RatioPress the Aspect button Press the Blank buttonUse the lever switch To adjust the level Using the Menu FunctionsPress the Menu button Operating the PC Screen Available Functions Remote Control OperationLamp High Voltage High Temperature High PressureDo not use the projector with the lamp cover removed Push Replacing the lampCaring for the air filter AIR FilterReplacing the air filter Other Care Caring for the cabinet and remote control transmitterCaring for the inside of the projector Caring for the lensPage For Technical see the end of this manual Use the lever switch Multifunctional SettingsMain Menu Main MenuPICTURE-2 Menu PICTURE-1 MenuPICTURE-1 Menu PICTURE-2 MenuInput Menu Input MenuAuto Menu Auto MenuScreen Menu Screen MenuOption Menu Wireless MenuOption Menu Related Messages Power Lamp Temp Regarding the Indicator LampsVol.2-2 Phenomena That May Easily Be Mistaken for Machine DefectsVol.2-3 Vol.2-7Dimension Diagram SpecificationsSpecification Unit mmWarranty and AFTER-SERVICE RGB in 1/2 Signal Connector PIN AssignmentSub 15-pin Shrink Resolution FH kHz FV Hz Rating Signal mode Display mode Example of Computer SignalInitial SET Signals ADB Mouse Connection to the Mouse ControlUSB Mouse PS/2 MouseConsist of header 7 bytes + command data 6 bytes Command dataRS-232C Communication ProtocolChanging the projector settings Set command Requesting projector status Get commandUsing the projector default settings Reset Command Increasing the projector setting value Increment commandC4 D3 Command data chartBe EF BA D2 Be EF AD D0 Be EF CB D0 Legal Information Audio Visual Products