Compaq 3134 manual Appendix B

Page 4

iv Compaq NC3134 Fast Ethernet Server Adapter User Guide

 

Class B Equipment

A-3

European Union Notice

A-3

China Taiwan Notice

A-3

Japanese Notice

A-4

Appendix B

 

Electrostatic Discharge

 

Grounding Methods

B-1

Appendix C

 

Specifications

 

NC3134 Fast Ethernet Server Adapter Specifications

C-1

Upgrade Module Specifications

C-2

NC3132 10/100 Upgrade Module

C-2

NC3135 10/100 Upgrade Module

C-2

NC6132 1000BASE-SX Upgrade Module

C-3

NC6133 1000BASE-LX Upgrade Module

C-3

NC3133 100BASE-FX Upgrade Module

C-3

NC7132 1000BASE-T (Gigabit over Copper) Upgrade Module

C-4

UTP Cable Specifications

C-4

Using UTP Category 5 Cable in Gigabit over Copper Installations

C-4

RJ-45 Pinouts and Crossover Function

C-5

10/100 Straight-Through Pinouts

C-5

10/100 Crossover Pinouts

C-6

Gigabit over Copper Internal Straight-Through Pinouts

C-6

Gigabit over Copper External Crossover Pinouts

C-8

Fiber Cable Specifications

C-9

Image 4
Contents NC3134 Fast Ethernet Server Adapter Page Contents Appendix B Symbols in Text About This GuideCompaq Technician Notes Where to Go for Additional HelpDownload the drivers, firmware, or documentation as needed Compaq Website Compaq Customer SupportPaqFax Number Worldwide Access Calling the Compaq Support LineNorth America Europe, the Middle East, and AfricaIntroduction OverviewNC3134 Adapter 2Compaq NC3134 Fast Ethernet Server Adapter User GuideNC3135 Upgrade Module Upgrade ModulesNC7132 Upgrade Module NC3133, NC6132, and NC6133 Fiber Upgrade Modules LED Indicator DescriptionsNC3134 and NC3135 LED Indicators UTP and Fiber Cable Specifications NC7132 LED IndicatorsNC7132 Gigabit Upgrade Module LED Indicators Fiber Upgrade Module LED IndicatorsInstalling the Upgrade Module Adapter Electrostatic Discharge PrecautionsInstalling the Upgrade Module on the Adapter Attaching the Upgrade ModuleRemoving the Adapter from a Server Installing the Upgrade Module and Adapter Installing the Adapter in a Server Installing the adapter in a serverConnecting the Network Cable Connecting UTP Network CableConnecting Fiber Network Cable UTP Network Cable TypesConnecting and Using Loop-Back Plugs RJ-45 Loop-Back PlugFederal Communications Commission Notice Regulatory Compliance NoticesClass a Equipment Class B Equipment ModificationsEuropean Union Notice Canadian Notice Avis CanadienChina Taiwan Notice Japanese Notice Electrostatic Discharge Grounding MethodsSpecifications NC3134 Fast Ethernet Server Adapter SpecificationsNC3132 10/100 Upgrade Module Upgrade Module SpecificationsNC3135 10/100 Upgrade Module NC6133 1000BASE-LX Upgrade Module NC6132 1000BASE-SX Upgrade ModuleNC3133 100BASE-FX Upgrade Module UTP Cable Specifications NC7132 1000BASE-T Gigabit over Copper Upgrade ModuleTable C-7 NC7132 Gigabit over Copper Upgrade Module Table C-8 UTP Cable SpecificationsRJ-45 Pinouts and Crossover Function 10/100 Straight-Through Pinouts10/100 Crossover Pinouts Table C-10 10/100 Pinouts Using External CrossoverGigabit over Copper Internal Straight-Through Pinouts Specifications C-7 Gigabit over Copper External Crossover Pinouts Table C-12 Gigabit over Copper Crossover PinoutsFiber Cable Specifications