Compaq 3134 manual Upgrade Module Specifications, NC3132 10/100 Upgrade Module

Page 26

C-2Compaq NC3134 Fast Ethernet Server Adapter User Guide

Upgrade Module Specifications

Environmental and safety specifications for the upgrade modules are the same as those for the NC3134 Server Adapter, as shown in Table C-1. All other specifications are the same except where noted.

NC3132 10/100 Upgrade Module

 

Table C-2

NC3132 10/100 Upgrade Module Specifications

 

 

Specification

Description

 

 

Network Controller Chipset

Intel 82558 MAC/PHY

 

 

Standards Supported

IEEE 802.3x, 802.3u,802.1p, and 802.1Q

 

 

Connector and Distances

See Table C-8

 

 

Dimensions

5.7 x 3.9 inches (L x W), 16.5 cm x 64 cm

 

 

Agency Approvals

See Table C-1

 

 

Power Requirements

800 mA @ 5V max

 

 

NC3135 10/100 Upgrade Module

Table C-3

NC3135 10/100 Upgrade Module Specifications

Specification

Description

 

 

Network Controller Chipset

Intel 82559 MAC/PHY

 

 

Standards Supported

IEEE 802.3x, 802.3u,802.1p, and 802.1Q

 

 

Connector and Distances

See Table C-8

 

 

Dimensions

5.7 x 3.9 inches (L x W) 16.5 cm x 64 cm

 

 

Agency Approvals

See Table C-1

 

 

Power Requirements

375 mA @ 5V max

 

 

Image 26
Contents NC3134 Fast Ethernet Server Adapter Page Contents Appendix B Symbols in Text About This GuideDownload the drivers, firmware, or documentation as needed Where to Go for Additional HelpCompaq Technician Notes PaqFax Number Compaq Customer SupportCompaq Website North America Worldwide AccessCalling the Compaq Support Line Europe, the Middle East, and AfricaIntroduction OverviewNC3134 Adapter 2Compaq NC3134 Fast Ethernet Server Adapter User GuideNC7132 Upgrade Module Upgrade ModulesNC3135 Upgrade Module NC3134 and NC3135 LED Indicators LED Indicator DescriptionsNC3133, NC6132, and NC6133 Fiber Upgrade Modules NC7132 Gigabit Upgrade Module LED Indicators UTP and Fiber Cable SpecificationsNC7132 LED Indicators Fiber Upgrade Module LED IndicatorsInstalling the Upgrade Module Adapter Electrostatic Discharge PrecautionsRemoving the Adapter from a Server Attaching the Upgrade ModuleInstalling the Upgrade Module on the Adapter Installing the Upgrade Module and Adapter Installing the Adapter in a Server Installing the adapter in a serverConnecting Fiber Network Cable Connecting the Network CableConnecting UTP Network Cable UTP Network Cable TypesConnecting and Using Loop-Back Plugs RJ-45 Loop-Back PlugClass a Equipment Regulatory Compliance NoticesFederal Communications Commission Notice Class B Equipment ModificationsChina Taiwan Notice Canadian Notice Avis CanadienEuropean Union Notice Japanese Notice Electrostatic Discharge Grounding MethodsSpecifications NC3134 Fast Ethernet Server Adapter SpecificationsNC3135 10/100 Upgrade Module Upgrade Module SpecificationsNC3132 10/100 Upgrade Module NC3133 100BASE-FX Upgrade Module NC6132 1000BASE-SX Upgrade ModuleNC6133 1000BASE-LX Upgrade Module Table C-7 NC7132 Gigabit over Copper Upgrade Module UTP Cable SpecificationsNC7132 1000BASE-T Gigabit over Copper Upgrade Module Table C-8 UTP Cable SpecificationsRJ-45 Pinouts and Crossover Function 10/100 Straight-Through PinoutsGigabit over Copper Internal Straight-Through Pinouts Table C-10 10/100 Pinouts Using External Crossover10/100 Crossover Pinouts Specifications C-7 Gigabit over Copper External Crossover Pinouts Table C-12 Gigabit over Copper Crossover PinoutsFiber Cable Specifications