| Section 5: Specifications |
| Viewing Angle | ' FOR | ± 38 degrees ± 2.0 degrees | |
| (to half gain) |
| Vertical | ± 9.5 degrees ± 1.0 degrees |
|
|
| ||
|
|
| FOR | ± 25 degrees ± 3.0 degrees |
|
|
| Vertical | ± 9 degrees ± 1.0 degrees |
|
|
| FOR | ± 35 degrees ± 3.0 degrees |
|
|
| Vertical | ± 35 degrees ± 3.0 degrees |
| Power Requirements | ' | Voltage range | 100 - 240 VAC |
|
|
| Line frequency | 50 Hz – 60 Hz nominal |
|
|
| Inrush current | 65A max @120V |
|
|
|
| 135A max @ 240V |
|
|
| Current rating | 2.5A @ 100V (typical), 1.05A @ |
|
|
|
| 240V (typical) |
|
|
| Power consumption | 250W @ 100V maximum |
|
|
|
| 250W @ 240V maximum |
| Lamps | ' | Type | 120W UHP |
|
|
| Power (user selectable) | 100W / 120W |
|
|
| <5 minutes | |
|
|
| Operating position | full rotation allowed about the lamp |
|
|
|
| axis |
| Lens | ' | 0.8:1 short throw |
|
|
|
| Image size range: 40” to 70” diagonal | |
Environmental Conditions | ' | Operating Temperature | 10°C to 35°C | |
|
|
| Humidity (for RPMX) | 20% to 90% |
|
|
| (for CX50/CX60) | 25% to 65% |
|
|
| (for CX67) | 40% to 60% |
|
|
| Altitude | 0 to 4000 meters, 10°C to 35°C |
|
|
| (for CX67) | 0 to 3000 meters, 17°C to 31°C |
|
|
| ||
|
|
| Humidity (for RPMX) | 20% to 95% |
|
|
| (for CX50/CX60) | 20% to 65% |
|
|
| (for CX67) | 35% to 65% |
|
|
| Altitude (for RPMX) | 0 to 15,000 meters, |
|
|
| (for CX50/CX60/CX67) | 0 to 15,000 meters, |
RPMX/CX50/CX60/CX67 User’s Manual