Proxima ASA DP5800 specifications Troubleshooting, Problem Possible Cause Action

Page 27

Troubleshooting

Check the following before asking for service.

If trouble continues, call your dealer or Proxima Technical Support.

Phone: 619-457-5500, Worldwide Web: http://www.proxima.com

Problem

Possible Cause

Action

Page

 

 

 

 

 

Power does not turn on.

• The Main power is not turned on.

• Turn the MAIN POWER switch on.

9

 

 

• The power cord is disconnected.

• Insert the power cord into an AC socket.

6

 

 

 

 

 

No picture or sound.

• The setting of the input source is not

• Set the correct input using the input

6, 7, 9

 

correct.

select button of the projector or the

 

 

 

 

remote control.

 

 

 

 

• Wiring to the projector is not correct.

• Connect the cable correctly.

6, 24

 

 

 

 

Picture is displayed with

• Wiring to the projector is not correct.

• Connect the cable correctly.

6, 24

no sound.

• The volume is set to minimum.

• Press the VOL button.

6,

7

 

 

• The unit is set in Mute mode.

• Press the MUTE button.

6,

7

 

 

 

 

Sound is heard with

• Wiring to the projector is not correct.

• Connect the cable correctly.

6, 24

no picture.

• The brightness is set too dark.

• Press the MENU button, select BRIGHT

12,

13

 

 

 

and press the

button.

 

 

 

 

 

 

 

Color is weak and tint is

The color and tint have been adjusted

Adjust the color and tint.

12,

13

incorrect.

incorrectly.

 

 

 

 

 

 

 

 

 

Picture is dark.

• The brightness and contrast have been

• Adjust the brightness and contrast.

12,

13

 

adjusted incorrectly.

 

 

26

 

• The lamp has not been adjusted.

• Replace the lamp with a new one.

 

 

 

 

 

 

 

 

Picture is not clear.

Focus is not correct.

Adjust the focus.

 

6, 7, 9

 

 

 

 

 

LAMP indicator glows

Trouble with the lamp.

Turn off the power and let it rest for 20

11,

26

red.

 

minutes. Then, turn the power on again.

 

 

 

 

 

 

TEMP indicator glows

Inside of the projector is too hot.

Check the ventilation holes.

11

red.

 

 

 

 

 

 

 

 

 

 

LAMP indicator blinks

Air filter is detached.

Reseat the air filter.

11,

26

red.

 

 

 

 

 

 

 

 

 

 

 

27

Image 27
Contents 5 8 0 DP5800 FeaturesImportant for the United Kingdom For Customers in the United KingdomVideo inputs Symbols Used in This GuideVideo signal cables Power cordSafety Precautions Do not place this unit where it gets hot Clean inside the unit every 24 monthsCleaning Handle the power cord carefullyYour DP5800 Projector Control use Top view Side view InstallationProjector and screen setup Using the foot adjustersProjecting the picture Using the ProjectorPress and hold the STANDBY/ON button for 1 second Turning off the powerMessage Projector Messages and IndicatorsStoring your settings Using the MenusE m Range SET UP MenuInput Menu Image MenuOptions OPT. Options Menu Adjustment Details of adjustmentLanguage Adjustment Item Details of adjustmentConnecting to an RGB Signal Connecting to a Video SourceVGA-3 Example of computer signalData Hsync Initial signal settingsConnecting to a Control Signal Control terminalMouse emulation PS/2 mouse ADB Mac mouse Serial mouse Communication settings Control command codesControl command table Control data table Sample of command error Procedure for checking projector statusProcedure for setting projector status Resetting the defaultsTypical system connections System SetupLamp Replacement Cleaning the air filterProblem Possible Cause Action TroubleshootingDimension diagram SpecificationsWarranty and Servicing Proxima CorporationMain Office