3M 2100 manual Troubleshooting, Symptom Check CAUSE/SOLUTIONS

Page 12

MODEL 2100 OVERHEAD PROJECTOR

SECTION 3 - TROUBLESHOOTING

SYMPTOM

 

CHECK

 

CAUSE/SOLUTIONS

 

 

 

 

Projected image is:

-

Is lamp of proper type? (See

- Damaged or misadjusted optics

a. Corners of projected image

 

label on underside of top cover)

 

components (requires

appear red (brown) or blue.

-

Is lamp properly seated down in

 

realignment of optics).

 

 

its socket and vertical?

- Head "knocked" out of

 

- If unit is equipped with a lamp

 

alignment.

 

 

changer, is changer lever fully

-

Adjust Color Tuning

 

 

seated in the number one

 

 

 

 

position?

 

 

 

 

 

 

 

b. Top, bottom, or sides of

-

Is lamp of proper type? (See

-

Adjust optics components

projected image are not

 

label on underside of Top

 

(requires realignment of

focused.

 

Cover)

 

optics).

 

- Is lamp properly seated down in

-

Lamp not seated.

 

 

its socket and vertical?

-

Reflector

 

- If unit is equipped with a lamp

-

Condenser

 

 

changer, is changer lever fully

 

 

 

 

seated in the number one

 

 

 

 

position?

 

 

 

- Are any of the optics

 

 

 

 

components noticeably

 

 

c. Not as bright as it should

 

"knocked" out of alignment?

 

 

 

 

 

 

be.

-

Is lamp of proper type? (See

-

Replace lamp.

 

 

label on underside of Top

- Damaged or misadjusted optics

 

 

Cover)

 

components (requires

 

- Is lamp properly seated down in

 

realignment of optics).

 

 

its socket and vertical?

-

Corroded wiring connection.

 

- If unit is equipped with a lamp

-

Wrong lamp on

 

 

changer, is changer lever fully

-

Reflector broken/missing

 

 

seated in the number one

 

 

 

 

position?

 

 

 

- Has another FNT lamp been

 

 

Focus mechanism slips or is

 

tried?

- To tighten, turn screw

 

 

too tight.

-

Focus tension screw needs

 

counterclockwise. To loosen,

 

 

adjustment

 

turn clockwise. Add update kit

 

 

 

 

if required. (see next page)

Lamp does not energize, but

 

 

-

Replace lamp.

fan motor does energize.

-

Is lamp burned out?

-

Replace overheat thermostat.

 

-

Is lamp of proper type? (See

- Replace lamp sensing switch

 

 

label on underside of top cover)

 

(only on projectors equipped

 

- Is lamp properly seated down in

 

with lamp changer).

 

 

its socket and vertical?

- Loose or broken wire

 

- If unit is equipped with a lamp

 

connection.

 

 

changer, is changer lever fully

-

Defective power supply.

 

 

seated in the number one

 

 

Neither lamp nor fan motor

 

position?

-

On-off switch defective.

 

 

energizes.

-

Is power cord plugged into

-

Defective interlock switch.

 

 

electrical outlet?

- Loose or broken wire

 

- Is outlet supplying power to

 

connection.

 

 

projector?

- On-off switch out of

 

 

 

 

 

 

 

 

 

adjustment.

 

 

 

- Replace Fuse (if equipped)

9/92

3-1

Image 12
Contents Model 2100 Overhead Projector Table of Contents Technical Support Hotline 1-800-328-1371 U.S. & CanadaIntroduction PhysicalModel 2100 Overhead Projector Electrical 2130/2140/2150 2160/2170/2180 4130/4140/41 MechanicalOptical 2130/2140/2150 2160/2170/2180 4130/41 40/4150Principles of Operation Operation and Maintenance Do not look in the front projection lens when lamp is onCUS Knob Method Cleaning Stage Glass and Fresnel Lens MirrorsLamp Changer Assembly Before S/N After S/N Troubleshooting Symptom Check CAUSE/SOLUTIONSTroubleshooting Field Kits AvailableAdjustments If floor or ceiling lines are not Optical Alignment Focus Mechanism 924-5 Tension in cable should be 3/16 MaximumPost should Fold Down Without TOO Much Force Page Page Page Page Page Page Page Page DISASSEMBLY/RE-ASSEMBLY Stage Glass Focusing Assembly How to remove and install the condenser lens when equipped