3M 2100 manual Electrical 2130/2140/2150 2160/2170/2180 4130/4140/41, Mechanical, Optical

Page 5

MODEL 2100 OVERHEAD PROJECTOR

Electrical

2130/2140/2150

2160/2170/2180

2160/2170/2180

 

4130/4140/41 50

 

 

Voltage

120/127/VAC

100VAC

220/230/240VAC

Frequency

60HZ

50/60HZ

50HZ

Current Rating

3.0 Amps

3.6 Amps

1.7 Amps

Power Cord

14-1/2' (4.4mm)

14-1/2' (4.4mm)

14-1 /2' (4.4mm)

Agency Approval

UL, CSA

-------

VDE, NEMKO,

 

 

 

SETI

Fuse

-------

F4 Amp - 250 Volt

SEMKO, SEV

 

F4 Amp - 250 Volt

 

 

 

Mechanical

Safety interlock: Shuts off power to the projector when the top cover assembly is opened.

Safety thermostat: Cuts power to the lamp if the projector exceeds safe operating temperature.

Color tuning knob: Allows projector to be easily color tuned for any screen size 1.0m x 1.0m (40" x 40") to 2.8m x 2.8m (110" x 110").

Projection Head Tilt - 0° - 20° (All Heads)

Lamp Changer - when lamp burns out, switch to standby lamp.

Optical

Lamp: ANSI Code FNT, 24 Volt, 275 Watt

Lamp Life: 75 Hours

 

 

 

 

2130/2140/2150

2160/2170/2180

 

4130/41 40/4150

 

Illumination:

 

2000 lumens typical;

2100 lumens typical;

1800 lumens minimum; 1900 lumens minimum;

Mirrors: Chassis mirror is second surface high reflective type. (After serial no. 435242) Projection mirror is front surface high reflective type.

 

2130, 2140, 2160, 2170

2150, 2180

 

 

4130/4140

4150

Head, Projection:

 

355mm (14.0" F.L.)

327mm (12.9" F.L.)

 

 

Doublet

Triplet - w/focus

 

 

293mm (11.5" F.L.)

correction

 

 

Singlet

330mm (13" F.L.)

 

 

 

 

After serial no. 411964

 

2130/21 40/2150

2160/2170/2180

 

4130/41 40/4150

 

Stage:

 

267mm x 267mm

285mm x 285mm

Transmissive

 

(10.5" x 10.5")

(11.2" x 11.2")

Aperture

 

 

 

 

9/92

1-2

Image 5
Contents Model 2100 Overhead Projector Technical Support Hotline 1-800-328-1371 U.S. & Canada Table of ContentsPhysical IntroductionModel 2100 Overhead Projector Mechanical Electrical 2130/2140/2150 2160/2170/2180 4130/4140/41Optical 2130/2140/2150 2160/2170/2180 4130/41 40/4150Principles of Operation Do not look in the front projection lens when lamp is on Operation and MaintenanceCUS Knob Method Mirrors Cleaning Stage Glass and Fresnel LensLamp Changer Assembly Before S/N After S/N Symptom Check CAUSE/SOLUTIONS TroubleshootingField Kits Available TroubleshootingAdjustments If floor or ceiling lines are not Optical Alignment Focus Mechanism Tension in cable should be 3/16 Maximum 924-5Post should Fold Down Without TOO Much Force Page Page Page Page Page Page Page Page DISASSEMBLY/RE-ASSEMBLY Stage Glass Focusing Assembly How to remove and install the condenser lens when equipped