Menu operation (continued)
2. INSTALLATION menu
| opt. |
|
INSTALLATION | AV MEMORY 1 | |
| KEYSTONE | 0 |
| LAMP MODE | STANDARD |
| AUTO POWER | OFF |
| ON | |
|
| |
| AUTO POWER | OFF |
| OFF | |
|
| |
ON | SPLASH | ON |
| SCREEN | |
|
| |
| BACK COLOR | BLUE |
| IMAGE | OFF |
| REVERSE | |
|
| |
| TRIGGER OUT | OFF |
| TEST PATTERN | CROSS HATCH |
2. INSTALLATION menu |
| |
ITEM | SETTING | FUNCTION |
KEYSTONE | ±15 | Use to correct vertical keystone distortion. |
LAMP MODE | STANDARD | Select this option when you want to view images in a |
| LOW | Select to moderate the intensity of the lamp. The fan operating sound is |
|
| reduced and the lamp lifetime becomes longer. |
AUTO POWER ON | ON / OFF | When ON is chosen, the lamp is automatically lit when the power cord is |
|
| plugged in the wall outlet. Choose ON when using the projector mounted on |
|
| the ceiling. |
•The projector is in the
AUTO POWER OFF | OFF / 5 - 60min | Use to set the time elapsed before the projector enters the | |||||
|
|
|
|
|
|
| when there is no signal input from the source. |
SPLASH SCREEN | ON / OFF | Choose ON to display the splash screen when the power is turned on. | |||||
BACK COLOR | BLUE / BLACK | Use to change the color of the screen that appears when no signal is | |||||
|
|
|
|
|
|
| supplied. |
IMAGE REVERSE | OFF | Select when viewing images from the front with the projector installed on the | |||||
|
|
|
|
|
|
| floor. |
| MIRROR | Select when viewing images projected from the behind of the screen with the | |||||
|
|
|
|
|
|
| projector installed on the floor. |
| INVERT | Select when viewing images projected from the behind of the screen with the | |||||
|
|
|
|
|
|
| projector installed on the ceiling. |
| MIRROR INVERT | Select when viewing images from the front with the projector installed on the | |||||
|
|
|
|
|
|
| ceiling. |
TRIGGER OUT | SCREEN | The trigger output signal (12 V) is output from the TRIGGER terminal when | |||||
|
|
|
|
|
|
| the lamp illuminates. |
| ANAMORPHIC | The trigger output signal (12 V) is output from the TRIGGER terminal when | |||||
|
|
|
|
|
|
| the aspect ratio is set to ANAMORPHIC 1 or ANAMORPHIC 2. |
| OFF | The trigger output signal (12V) isn’t output. | |||||
TEST PATTERN | CROSS HATCH |
| Select to show the test cross hatch pattern. | ||||
| |||||||
| WHITE |
|
|
|
| Select to show the maximum brightness image. | |
|
|
| |||||
| BLACK |
|
| Select to show the minimum brightness image. | |||
|
| ||||||
|
|
|
|
|
|
|
|
•The STANDARD lamp mode is activated by default whenever the projector is turned on. When the LOW LAMP MODE has been chosen, the default STANDARD lamp mode is switched to the LOW lamp mode in 1 minute.
•When the lamp mode is switched, the projected image may flicker. This is not a product malfunction.
•Do not change the setting of LAMP MODE frequently.
•To cancel the test pattern, press any button.