Polaroid SprintScan 45 manual Power OFF on the SCANNER, the Computer

Page 13

 

The SprintScan 45 scanner is unterminated. If it is the last

 

device in the chain, add a terminator. See the illustrations on

 

pages 2-9–2-10.

 

Powerbook note: According to Apple Computer, even

 

though this computer has an internal hard disk, you should

 

treat it as an unterminated device. This means that you must

 

have two terminators on the SCSI chain. Apple also advises

 

that if you have only one device connected to a Powerbook,

 

you must have two terminators on this one device. Refer to

 

the documentation included with your PowerBook.

Connection tips

• WARNING: ALL CONNECTIONS MUST BE MADE WITH

 

THE POWER OFF ON THE SCANNER, THE COMPUTER,

 

AND ALL SCSI DEVICES.

 

• Always make SCSI connections firmly, connecting the clips or

 

tightening the screws that secure cables and terminators. Most

 

problems with SCSI devices are connection problems along

 

the SCSI chain.

 

• The SprintScan 45 scanner has two SCSI connectors; one has

 

50 pins and one has 25. A SCSI cable can be connected to

 

either port without affecting the performance of your equip-

 

ment.

 

• Each device on a SCSI chain must have a unique SCSI ID

 

number. These numbers are described in the following

 

section.

 

• If a 50-to-50 pin cable is required, be sure to use a cable

 

which meets the SCSI-2 specification, such as an Apple cable.

2-4

Image 13
Contents Page Table of contents Appendix a Specifications Index Quick Scanning Guide N t ro d u c t i o n Scanning modes System re q u i re m e n t s Registration card Technical SupportP a c k i n g Scanner and accessories Setup and useRear panel Scsi guidelines Positioning the scannerPower OFF on the SCANNER, the Computer ID number 7. The Macintosh internal hard drive usually uses Scsi ID numbersConnecting the scanner to your computer Installing a Scsi adapter in a PCSetup and use Diagrams of various Scsi configurations Tu rning on the scanner Using the film carr i e r s Setup and use 120 film adapters For 2 1/4 x 2 1/4 4 x 2 3/4 in. film Single-35mm Carrier Removing the carr i e r S e rting the carrier into the scannerI n t e n a n c e A re and maintenanceTro u b l e s h o o t i n g Service Limited One Year Equipment WarrantyBelgique/België L a roid Offices and Service CentersNew Zealand Radio and television interference Appendix a Specifications 40W D e Scsi