Nokia 12 GSM MODULE REMOTE I/O Reading and Writing Parameters, Defining the Message Identifier

Page 13

4.4READING AND WRITING PARAMETERS

To read parameter values from the Nokia 12 GSM Module and write parameter values to it, use Configurator. Each Configurator dialog has “Read parameters” and “Write parameters” button for this purpose. Data is transferred between Configurator and the Nokia 12 GSM Module only after you have clicked either of these buttons.

Note: To apply the configured settings, click either the Read parameters or Write parameters button.

Some of the settings require that you reset the Nokia 12 GSM Module before they take effect. Either click the Reset button on the test board or remove and plug in the power cord on the test board. You can also use Configurator to reset the Nokia 12 GSM Module (File -> Reboot Module).

Note: The Nokia 12 GSM Module should be reset after you have configured all parameter values.

After a parameter value has been successfully configured to the Nokia 12 GSM Module, the dialog in Figure 1 appears.

Figure 1. Dialog for successful parameter configuration

4.5DEFINING THE MESSAGE IDENTIFIER

The message identifier is a mandatory setting that must be configured in order to use the Remote I/O control. Figure 2 shows a dialog (User Control Mode -> Settings -> Initialize) where you can set the identifier in Configurator. To define the message identifier, press Change. See Figure 2.

Note: Press the Write parameters button to activate the new identifier.

After you have set the message identifier, more parameters become available. If a message identifier has been previously defined to the Nokia 12 GSM Module, press the Read parameters button to enable the additional parameters.

9/49

Image 13
Contents Nokia 12 GSM Module Contents Page Legal Notice Acronyms and Terms About this Document General IntroductionRemote I/O Control Functions in the Remote I/O controlPage Security Page Getting Started Setting UP the Configurator EnvironmentMandatory Settings Connecting a Device or a MachineDefining the Message Identifier Reading and Writing ParametersUser Control Mode dialog Short Messages dialog Setting the SMS Centre Address12/49 Disabling Acknowledgements Optional ConfigurationsGeneral settings Authorised numbers Security SettingsSecurity settings Authentication Aliasing Setting aliases for device commands Input Settings Input settings Default Output Value Setting21/49 INPUT/OUTPUT PIN Descriptions PIN descriptions Port settings in Configurator Supported Characters Characters supported by Configurator for Remote I/O controlCommand Syntax Commands Remote I/O Control SMS CommandsList of commands Status Messages Changing the Password Detailed Command Information and ResponsesList of response messages Reading Inputs Commands for the password controlChangepword Failed Changepword OKInputget ALL OK InputGet X commandsINPUT1 Y Inputget X OKSubscribing to Input Alarms InputGetChange commands for alarm functionality Reading Outputs InputchangecancelInputgetchange Z Writing Outputs OutputGet X commandsOutputget X OK Output X YOutputSet X commands Inverting Outputs OutputInvert X commandsOutputinvert X OK Output X Y Output 7 Output 8 Output 9 Output PulsesOutputpulse X on OutputPulse X commandsOutput X Locked Outputpulse X OFFOutput Pulse OFF time Error Network Time Missing Cancelling Output PulsesOutputpulsecancel OutputPulseCancel X commandsOutput X Pulse Cancelled Term123 Outputpulse 1 on 5s Location information GPS support configured to serial portBbbbbbbbb Location LocationgetLocation Latitude LongitudeNetwork Support Safety InformationMedical Devices AntennaVehicles Potentially Explosive Environments Care and Maintenance49/49

12 GSM MODULE REMOTE I/O specifications

The Nokia 12 GSM Module Remote I/O stands out as a robust solution for remote monitoring and control in various applications. Designed to seamlessly integrate cellular connectivity with remote input and output functionalities, this module is particularly valuable in industries such as utilities, transportation, and industrial automation.

One of the primary features of the Nokia 12 GSM Module is its GSM connectivity, allowing it to operate over existing cellular networks. This connectivity ensures reliable communication across vast distances, making it an ideal choice for remote locations where traditional networking options are impractical. With support for both 2G and 3G networks, the module caters to diverse geographical requirements, providing flexibility depending on regional infrastructure.

The module supports multiple I/O configurations, including digital and analog inputs and outputs. This versatility enables users to monitor various sensors and control different devices remotely. For instance, it can process data from temperature sensors, pressure gauges, and flow meters while allowing remote control of pumps, valves, and other actuators. This combination of input/output capabilities simplifies the integration into existing systems.

Another notable characteristic of the Nokia 12 GSM Module is its built-in power management features. The module is designed to operate efficiently, utilizing low standby power, which is particularly important for battery-powered applications. This efficiency not only extends the lifespan of power sources but also reduces operational costs, making it a cost-effective solution over time.

Advanced security features are also a hallmark of the Nokia 12 GSM Module. It employs encryption protocols to safeguard data transmissions, protecting sensitive information from unauthorized access. This emphasis on security is essential in industries where data integrity and privacy are paramount.

The module is engineered for rugged environments, boasting a wide temperature operating range and resistance to humidity and dust. Its durable construction ensures that it remains operational in challenging conditions, thereby enhancing its reliability for outdoor or industrial use.

Adding to its capabilities, the Nokia 12 GSM Module can be easily interfaced with various cloud platforms. This compatibility enables real-time data reporting and remote access, empowering users to monitor their systems from anywhere in the world.

In summary, the Nokia 12 GSM Module Remote I/O is a comprehensive solution that provides GSM connectivity, versatile I/O options, energy efficiency, robust security, and durability. These features make it a valuable instrument for enhancing operational efficiency and enabling advanced automation in remote applications.