Pioneer PDP-502MXE Wall-mount installation of the unit, Rear view diagram, Side view diagram

Page 13

Installation and Connections

Installation using the optional PIONEER stand or installation bracket

ÖPlease be sure to request installation or mounting of this unit or the installation bracket by an installation specialist or the dealer where purchased.

ÖWhen installing, be sure to use the bolts provided with the stand or installation bracket.

ÖFor details concerning installation, please refer to the instruction manual provided with the stand or installation bracket.

Installation using accessories other than the PIONEER stand or installation bracket (sold separately)

ÖWhen possible, please install using parts and accessories manufactured by PIONEER. PIONEER will not he held responsible for accident or damage caused by the use of parts and accessories manufactured by other companies.

ÖFor custom installation, please consult the dealer where the unit was purchased, or a qualified installer.

Wall-mount installation of the unit

This unit has been designed with bolt holes for wall-mount installation, etc.. The installation holes that can be used are shown in the diagram below. (Hole rivets can be removed by turning with a screwdriver, coin or similar tool.)

ÖBe sure to attach in 4 or more locations above and below, left and right of the center line.

ÖUse bolts that are long enough to be inserted 12 mm to 20 mm into the main unit from the attaching surface for both a holes and b holes. Refer to the side view diagram below.

ÖAs this unit is constructed with glass, be sure to install it on a flat, unwarped surface.

English

b hole

b hole

a hole

b hole

Air vents (fan)

b hole

a hole

Center line

b hole

 

Attaching surface

Installation bracket, etc..

Main unit

 

a hole

 

 

 

Center line

 

 

Bolt

 

 

b hole

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12 mm to 20 mm

Bolt

bhole

12 mm to 20 mm

Installation and Connections

Rear view diagram

CAUTION

To avoid malfunction, overheating of this unit, and possible fire hazard, make sure that the vents on the main unit are not blocked when installing. Also, as hot air is expelled from the air vents, be careful of deterioration and dirt build up on rear surface wall, etc..

CAUTION

Please be sure to use an M8 (Pitch = 1.25 mm) bolt. (Only this size bolt can be used.)

Side view diagram

CAUTION

Because this unit weighs about 40 kg and has little depth making it unstable, please use 2 people or more when packing, carrying or installing.

CAUTION

This unit incorporates a thin design. To ensure safety if vibrated or shaken, please be sure to take measures to prevent the unit from tipping over.

9

<ARE1350> En

Image 13 Contents
PDP-502MXE Page Basic Operations English Safety PrecautionsContents FeaturesBefore Proceeding How to Use This ManualAbout operations in this manual Remote control unit Checking supplied accessoriesOperating Instructions Before Proceeding Main unit Part Names and FunctionsOperation panel on the main unit Main unit Remote control unit Connection panel ~ Speaker L terminal Main Power switchInstallation of the unit Installation and ConnectionsInstallation using the supplied display stand Set this unit in the standRear view diagram Wall-mount installation of the unitSide view diagram When connecting to INPUT4 When connecting to INPUT3When connecting to INPUT4 Output Connection of separate Sync analog RGB sourceAudio connections Connecting the speakersControl cord connection Making connections to the audio inputs on this unitHow to route cables Power cord connectionOrganize cables together using the provided speed clamps To attach the speed clamps to the main unitSetup of G on Sync Clamp connection Operations Press STANDBY/ON to put this unit in the operation modeBefore you begin, make sure you have To confirm display settings To adjust the volumePress Muting on the remote control unit To mute the soundChanging the screen size Screen size selectionPress Screen Size to select the size NormalPress SET to select the Power Save mode To put the unit in operation mode againPress 5/ to select PC Menu screenAdjusting the picture quality Display Panel AdjustmentsTo reset Picture mode settings to the default To reset Screen mode settings to the default Adjusting the display imagePress 2/3 to carry out the adjustment Screen mode adjustment itemsDisplay Panel Adjustments Press 5/ to select ABL Press 5/ to select SET UP, then press SETMaking the PC image brighter ABL Press 2/3 to adjust Resetting the unit to factory set defaultsPress 5/ to select H. Enhance or V. ENHANCE, then press SET Press 2 to select YES, then press SETInserting the batteries in the remote control unit CleaningAdditional Information Troubleshooting Operating range of the remote control unitGeneral Problems About the self diagnosis mode Problems commonly mistaken as breakdownAdditional cautions InformationAccessories SpecificationsPanel sticking and after-image lag GeneralSupplement PC signal compatibilty table INPUT3, INPUT4Aspect ratio Explanation of TermsCommencer Precautions de securiteFrance tapez 36 15 Pioneer