InFocus IN5542C, IN5544C user manual Command Format TCP #23, Protocol

Page 11

Command Control via the Network (continued)

Command Format

[TCP #23]

1. Protocol

Consist of header (7 bytes) + command data (6 bytes)

2. Header

BE + EF + 03 + 06 + 00 + CRC_low + CRC_high

CRC_low: Lower byte of CRC flag for command data

CRC_high: Upper byte of CRC flag for command data

3.Command data

Command data chart

byte_0

byte_1

 

byte_2

byte_3

 

byte_4

 

byte_5

 

Action

 

 

Type

 

Setting code

 

low

high

 

low

high

 

low

 

high

 

Action (byte_0 - 1)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Action

Classification

 

 

Content

 

 

1

Set

 

Change setting to desired value.

 

2

Get

 

Read projector internal setup value.

 

4

Increment

 

Increment setup value by 1.

 

 

5

Decrement

 

Decrement setup value by 1.

 

 

6

Execute

 

Run a command.

 

 

Requesting projector status (Get command)

(1)Send the following request code from the PC to the projector.

Header + Command data (‘02H’ + ‘00H’ + type (2 bytes) + ‘00H’ + ‘00H’)

(2)The projector returns the response code ‘1DH’ + data (2 bytes) to the PC.

Changing the projector settings (Set command)

(1)Send the following setting code from the PC to the projector.

Header + Command data (‘01H’ + ‘00H’ + type (2 bytes) + setting code (2 bytes))

(2)The projector changes the setting based on the above setting code.

(3)The projector returns the response code ‘06H’ to the PC.

Using the projector default settings (Reset Command)

(1)The PC sends the following default setting code to the projector.

Header + Command data (‘06H’ + ‘00H’ + type (2 bytes) + ‘00H’ + ‘00H’)

(2)The projector changes the specified setting to the default value.

(3)The projector returns the response code ‘06H’ to the PC.

Increasing the projector setting value (Increment command)

(1)The PC sends the following increment code to the projector.

Header + Command data (‘04H’ + ‘00H’ + type (2 bytes) + ‘00H’ + ‘00H’)

(2)The projector increases the setting value on the above setting code.

(3)The projector returns the response code ‘06H’ to the PC.

11

Image 11
Contents IN5542/IN5542c/IN5544/IN5544c Computer signal examplesInitial set signals Component Video E Y, F Cb/Pb, G Cr/Pr Connection to the portsBNC G/Y, B/Cb/Pb, R/Cr/Pr, H Remote Control K in L OUT LAN Erst ? PJLink commandLamp ? RS-232C Communication Connecting the cableCommunications setting Increasing the projector setting value Increment command Requesting projector status Get commandChanging the projector settings Set command Using the projector default settings Reset CommandCommunication Port Command Control via the NetworkCommand Control Settings Command Format TCP #23 Check Sum When authentication error occurredTCP #9715 Data LengthReply Data AuthenticationAutomatic Connection Break Daisy Chain Communication Commands available only for daisy chain communicationCommand format Calculation of Checksum Group and ID Settings① Controlling projector Command data Get the number of connected projectors Manual detailed Operating Guide CRC RS-232C Communication / Network command tableBe EF C7 FF EA F5 IN5542/IN5542c only. *2 IN5544/IN5544c only PAL BNC BA F6 BNC Be EF Display Be EF Channel MY BUTTON-1 Be EF DE 3F Be EF AA C2 Be EF CB D3