InFocus IN5542C, IN5544C user manual Be EF Channel

Page 28

RS-232C Communication / Network command table

Names 

 

Operation Type

 

Header

 

 

 

Command Data

 

 

 

 

CRC

Action

 

Type

 

Setting Code

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CLOSED CAPTION

Set

1

BE EF

 

03

 

06 00

D2 62

01 00

 

02 37

 

01 00

CHANNEL

 

2

BE EF

 

03

 

06 00

22 62

01 00

 

02 37

 

02 00

 

 

3

BE EF

 

03

 

06 00

B2 63

01 00

 

02 37

 

03 00

 

 

4

BE EF

 

03

 

06 00

82 61

01 00

 

02 37

 

04 00

 

 

Get

BE EF

 

03

 

06 00

71 63

02 00

 

02 37

 

00 00

SOURCE SKIP

Set

NORMAL

BE EF

 

03

 

06 00

FE 78

01 00

 

20 22

 

00 00

COMPUTER IN 1

 

SKIP

BE EF

 

03

 

06 00

6E 79

01 00

 

20 22

 

01 00

 

 

Get

BE EF

 

03

 

06 00

CD 78

02 00

 

20 22

 

00 00

SOURCE SKIP

Set

NORMAL

BE EF

 

03

 

06 00

CE 79

01 00

 

24 22

 

00 00

COMPUTER IN 2

 

SKIP

BE EF

 

03

 

06 00

5E 78

01 00

 

24 22

 

01 00

 

 

Get

BE EF

 

03

 

06 00

FD 79

02 00

 

24 22

 

00 00

SOURCE SKIP

Set

NORMAL

BE EF

 

03

 

06 00

8A 79

01 00

 

27 22

 

00 00

BNC

 

SKIP

BE EF

 

03

 

06 00

1A 78

01 00

 

27 22

 

01 00

 

 

Get

BE EF

 

03

 

06 00

B9 79

02 00

 

27 22

 

00 00

SOURCE SKIP

Set

NORMAL

BE EF

 

03

 

06 00

BA 78

01 00

 

23 22

 

00 00

HDMI

 

SKIP

BE EF

 

03

 

06 00

2A 79

01 00

 

23 22

 

01 00

 

 

Get

BE EF

 

03

 

06 00

89 78

02 00

 

23 22

 

00 00

SOURCE SKIP

Set

NORMAL

BE EF

 

03

 

06 00

62 7B

01 00

 

29 22

 

00 00

DVI-D

 

SKIP

BE EF

 

03

 

06 00

F2 7A

01 00

 

29 22

 

01 00

 

 

Get

BE EF

 

03

 

06 00

51 7B

02 00

 

29 22

 

00 00

SOURCE SKIP

Set

NORMAL

BE EF

 

03

 

06 00

32 78

01 00

 

25 22

 

00 00

COMPONENT

 

SKIP

BE EF

 

03

 

06 00

A2 79

01 00

 

25 22

 

01 00

 

 

Get

BE EF

 

03

 

06 00

01 78

02 00

 

25 22

 

00 00

SOURCE SKIP

Set

NORMAL

BE EF

 

03

 

06 00

46 79

01 00

 

22 22

 

00 00

S-VIDEO

 

SKIP

BE EF

 

03

 

06 00

D6 78

01 00

 

22 22

 

01 00

 

 

Get

BE EF

 

03

 

06 00

75 79

02 00

 

22 22

 

00 00

SOURCE SKIP

Set

NORMAL

BE EF

 

03

 

06 00

02 79

01 00

 

21 22

 

00 00

VIDEO 1

 

SKIP

BE EF

 

03

 

06 00

92 78

01 00

 

21 22

 

01 00

 

 

Get

BE EF

 

03

 

06 00

31 79

02 00

 

21 22

 

00 00

SOURCE SKIP

Set

NORMAL

BE EF

 

03

 

06 00

26 7B

01 00

 

2A 22

 

00 00

VIDEO 2

 

SKIP

BE EF

 

03

 

06 00

B6 7A

01 00

 

2A 22

 

01 00

 

 

Get

BE EF

 

03

 

06 00

15 7B

02 00

 

2A 22

 

00 00

AUTO SEARCH

Set

OFF

BE EF

 

03

 

06 00

B6 D6

01 00

 

16 20

 

00 00

 

 

ON

BE EF

 

03

 

06 00

26 D7

01 00

 

16 20

 

01 00

 

 

Get

BE EF

 

03

 

06 00

85 D6

02 00

 

16 20

 

00 00

DIRECT ON

Set

OFF

BE EF

 

03

 

06 00

3B 89

01 00

 

20 31

 

00 00

 

 

ON

BE EF

 

03

 

06 00

AB 88

01 00

 

20 31

 

01 00

 

 

Get

BE EF

 

03

 

06 00

08 89

02 00

 

20 31

 

00 00

AUTO OFF

 

Get

BE EF

 

03

 

06 00

08 86

02 00

 

10 31

 

00 00

 

 

Increment

BE EF

 

03

 

06 00

6E 86

04 00

 

10 31

 

00 00

 

 

Decrement

BE EF

 

03

 

06 00

BF 87

05 00

 

10 31

 

00 00

SHUTTER TIMER

Set

1h

BE EF

 

03

 

06 00

27 92

01 00

 

06 24

 

01 00

 

 

3h

BE EF

 

03

 

06 00

47 93

01 00

 

06 24

 

03 00

 

 

6h

BE EF

 

03

 

06 00

17 90

01 00

 

06 24

 

06 00

 

 

Get

BE EF

 

03

 

06 00

84 93

02 00

 

06 24

 

00 00

LAMP TIME LOW

 

Get

BE EF

 

03

 

06 00

C2 FF

02 00

 

90 10

 

00 00

LAMP TIME HIIGH

 

Get

BE EF

 

03

 

06 00

2A FD

02 00

 

9E 10

 

00 00

LAMP TIME Reset

 

Execute

BE EF

 

03

 

06 00

58 DC

06 00

 

30 70

 

00 00

FILTER TIME LOW

 

Get

BE EF

 

03

 

06 00

C2 F0

02 00

 

A0 10

 

00 00

FILTER TIME HIGH

 

Get

BE EF

 

03

 

06 00

D6 FC

02 00

 

9F 10

 

00 00

FILTER TIME Reset

 

Execute

BE EF

 

03

 

06 00

98 C6

06 00

 

40 70

 

00 00

28

Image 28
Contents Computer signal examples IN5542/IN5542c/IN5544/IN5544cInitial set signals BNC G/Y, B/Cb/Pb, R/Cr/Pr, H Connection to the portsComponent Video E Y, F Cb/Pb, G Cr/Pr Remote Control K in L OUT LAN PJLink command Erst ?Lamp ? Communications setting Connecting the cableRS-232C Communication Requesting projector status Get command Changing the projector settings Set commandUsing the projector default settings Reset Command Increasing the projector setting value Increment commandCommand Control Settings Command Control via the NetworkCommunication Port Command Format TCP #23 When authentication error occurred TCP #9715Data Length Check SumAutomatic Connection Break AuthenticationReply Data Command format Commands available only for daisy chain communicationDaisy Chain Communication Group and ID Settings Calculation of Checksum① Controlling projector Command data Get the number of connected projectors Manual detailed Operating Guide RS-232C Communication / Network command table CRCBe EF C7 FF EA F5 IN5542/IN5542c only. *2 IN5544/IN5544c only PAL BNC BA F6 BNC Be EF Display Be EF Channel MY BUTTON-1 Be EF DE 3F Be EF AA C2 Be EF CB D3