InFocus IN5542C, IN5544 TCP #9715, When authentication error occurred, Data Length, Check Sum

Page 12

Command Control via the Network (continued)

Decreasing the projector setting value (Decrement command)

(1)The PC sends the following decrement code to the projector.

Header + Command data (‘05H’ + ‘00H’ + type (2 bytes) + ‘00H’ + ‘00H’)

(2)The projector decreases the setting value on the above setting code.

(3)The projector returns the response code ‘06H’ to the PC.

When the projector cannot understand the received command

When the projector cannot understand the received command, the error code ‘15H’ is sent back to the PC.

Sometimes the projector cannot properly receive the command. In this case, the command is not executed and the error code ‘15H’ is sent back to the PC. If this error code is returned, send the same command again.

When the projector cannot execute the received command.

When the projector cannot execute the received command, the error code ‘1CH’ + ‘xxxxH’ is sent back to the PC.

When the data length is greater than indicated by the data length code, the projector will ignore the excess data code. Conversely when the data length is shorter than indicated by the data length code, an error code will be returned to the PC.

When authentication error occurred.

When authentication error occurred, the error code the ‘1FH’ + ‘0400H’ is sent back to the PC.

NOTE • Operation cannot be guaranteed when the projector receives an undefined command or data.

Provide an interval of at least 40ms between the response code and any other code.

Commands are not accepted during warm-up.

[TCP #9715]

1. Protocol

Consist of header (1 byte) + data length (1 byte) + command data (13 bytes) + check sum (1 bytes) + connection ID (1 byte).

2.Header

02, Fixed

3.Data Length

Network control commands byte length (0D, Fixed)

4. Command data

Network control commands that start with BE EF (13bytes).

5. Check Sum

This is the value to make zero on the addition of the lower 8 bits from the header to the checksum.

6. Connection ID

Random value from 0 to 255 (This value is attached to the reply data).

12

Image 12
Contents Computer signal examples IN5542/IN5542c/IN5544/IN5544cInitial set signals Connection to the ports BNC G/Y, B/Cb/Pb, R/Cr/Pr, HComponent Video E Y, F Cb/Pb, G Cr/Pr Remote Control K in L OUT LAN PJLink command Erst ?Lamp ? Connecting the cable Communications settingRS-232C Communication Requesting projector status Get command Changing the projector settings Set commandUsing the projector default settings Reset Command Increasing the projector setting value Increment commandCommand Control via the Network Command Control SettingsCommunication Port Command Format TCP #23 When authentication error occurred TCP #9715Data Length Check SumAuthentication Automatic Connection BreakReply Data Commands available only for daisy chain communication Command formatDaisy Chain Communication Group and ID Settings Calculation of Checksum① Controlling projector Command data Get the number of connected projectors Manual detailed Operating Guide RS-232C Communication / Network command table CRCBe EF C7 FF EA F5 IN5542/IN5542c only. *2 IN5544/IN5544c only PAL BNC BA F6 BNC Be EF Display Be EF Channel MY BUTTON-1 Be EF DE 3F Be EF AA C2 Be EF CB D3