JVC LM-H171, LM-H191 External Control, About the external control, Using the MAKE/TRIGGER system

Page 14

External Control

7About the external control

This monitor has the MAKE/TRIGGER terminal, which allows you to control the monitor by the make contact or the trigger system.

MAKE (make contact) system: Controls the monitor by short-circuiting the corresponding pin terminal to the GND pin terminal, or disconnecting (opening) it.

TRIGGER (trigger) system: Controls the monitor by sending the pulse signal instantaneously to the corresponding pin terminal.

Control priority is as follows.

MAKE > TRIGGER/buttons and menu on the monitor

• You can use the external control even when “CONTROL LOCK” is set to “ON” (page 12).

7Using the MAKE/TRIGGER system

The MAKE/TRIGGER terminal is configured as follows. You can assign a function to each pin terminal in “REMOTE SETTING” (“PORT F1” – “PORT F6” on page 12).

• You cannot change the functions assigned to the pin terminals from 7th and 8th.

 

 

 

 

 

Pin No.

Pin name

 

Pin No.

Pin name

 

 

 

 

 

1

PORT F1

 

5

PORT F5

 

 

 

 

 

 

 

 

 

 

2

PORT F2

 

6

PORT F6

 

 

 

 

 

3

PORT F3

7

ENABLE*1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

This is a female terminal.

4

PORT F4

8

GND

 

 

 

 

 

*1 The 7th pin terminal makes the external control valid/ invalid. Make sure to control the terminal by the MAKE system.

To assign the functions to the pin terminals

For the operation procedure, see page 7.

1Select “REMOTE SETTING” on the SET UP MENU.

2Select a pin name (“PORT F1” – “PORT F6”) for which you want to assign a function, then select the function you want to assign.

• For selectable functions, see the tables below.

Display

Functions to be controlled

Opening

Short-circuiting

VIDEO 1

Changes the input to “VIDEO 1.”

Invalid

Valid

 

 

 

 

 

 

 

VIDEO 2

Changes the input to “VIDEO 2.”

Invalid

Valid

 

 

 

 

 

 

 

RGB

Changes the input to “RGB.”

Invalid

Valid

 

 

 

 

 

 

 

DVI

Changes the input to “DVI.”

Invalid

Valid

 

 

 

 

 

 

 

STD.

Changes the Picture Mode to “STD.”

Invalid

Valid

 

 

 

 

 

 

 

DARK

Changes the Picture Mode to “DARK

Invalid

Valid

ENHANCED

ENHANCED.”

 

 

 

 

 

VIVID

Changes the Picture Mode to “VIVID.”

Invalid

Valid

 

 

 

 

 

 

 

DYNAMIC

Changes the Picture Mode to “DYNAMIC.”

Invalid

Valid

 

 

 

 

 

 

 

AUTO ADJ.

Adjusts the size/position of the picture.

Invalid

Valid

 

 

 

 

 

 

 

SCAN SIZE

Selects the screen size.

OVER

NARROW

 

 

 

 

 

 

 

ASPECT

Changes the aspect ratio.

4:3

 

 

16:9

STAND BY/ON*2

Turns on/off (on standby) the power.

page 6 “p

 

 

 

button”

 

 

 

 

 

 

 

 

 

 

 

 

– – –

No function

 

*

You cannot assign the same function to different pin terminals.

The TRIGGER system switches each function by short-circuiting the pin terminal for about 1 second and opening it.

*2 Must be controlled with the TRIGGER system.

Operation

1Select the control method (“SYSTEM”) in “REMOTE SETTING.”

2Short-circuit the 7th pin terminal (ENABLE) to the 8th pin terminal (GND) so that the monitor can be controlled by the external control.

3When selecting “MAKE”: Operate each function by short-circuiting the corresponding pin terminal to the 8th pin terminal (GND) or opening it.

When selecting “TRIGGER”: Operate each function by pulse control, that is short-circuiting the corresponding pin terminal to the 8th pin terminal (GND) for about 1 second and opening it.

When changing the input or Picture Mode with the MAKE system, only one pin terminal must be short-circuited. (Other pin terminals must be opened.)

When selecting the TRIGGER system, you can operate only one function at a time. Operate the functions one by one.

ENGLISH

13

Image 14
Contents LM-H191 LM-H171 Illustration of the monitor is of LM-H191Instructions LCD Display Monitor Turn off the power Unplug this product from the wall outlet Safety PrecautionsHow to replace the fuse Under the following conditionsImportant Recycling Information MaintenanceEuropean Union only Installation You can tilt the monitor as followsFixing the monitor Fix the monitor to a wall by using stringsHigher position Lower position Daily Operations / Connections Front panelPressing the button again finishes the menu operation For some items, adjustments will be Made by pressingConfirmation message appears Rear panel GND Y Available signalsVideo RGB GND CMenu Configuration-MAIN Menu Adjusts the standard level for the picture adjustment Control Lock Setting value OFF, on Setting for the external control External Control onSetting for the synchronization with signals C.SYNC input level is TTLAbout the external control Using the MAKE/TRIGGER systemExternal Control Troubleshooting Monitor is malfunctioning SpecificationsGeneral Model name LM-H191 LM-H171Dimensions Input/output terminalsVictor Company of Japan, Limited