HOW TO USE EXTERNAL
CONTROL
⬛ABOUT EXTERNAL CONTROL
The
One is the MAKE/TRIGGER terminal, which allows the monitor to be controlled by the MAKE(make contact) or TRG. (trigger contact) method selected in the function setting.
MAKE (make contact system): Controls the function by stable disconnection (terminal open) or
TRG. (trigger system) : Controls the function by instantaneously (one second)
*MAKE or TRIGGER are selected from REMOTE SELECT in the setup menu.
*The 14th terminal (REMOTE ENABLE) is always controlled by the make contact system regardless of the REMOTE SELECT setting.
The other terminal used for remote control is the
NOTE: Control priority is in the following order; 1 MAKE/TRIGGER terminal >
⬛HOW TO USE THE MAKE/TRIGGER TERMINAL
Connections
Connect
The Names and Functions of Terminals
10 | 9 |
| 8 |
| 7 | 6 |
|
| 5 4 3 2 1 |
|
| ||
| 15 | 14 | 13 | 12 | 11 |
|
No. | Names | Functions | Operations (OFF p[ ON) | *1 | |
1 | TALLY | Puts on the tally lamp. | Put off | Put on |
|
|
|
|
|
|
|
2 | INPUT A | Changes the input to INPUT A | Not change | Change |
|
3 | INPUT B | Changes the input to INPUT B | Not change | Change |
|
|
|
|
|
|
|
4 | INPUT C | Changes the input to INPUT C | Not change | Change |
|
|
|
|
|
|
|
5 | INPUT D | Changes the input to INPUT D | Not change | Change |
|
6 | INPUT E | Changes the input to INPUT E | Not change | Change |
|
|
|
|
|
|
|
7 | INPUT F | Changes the input to INPUT F | Not change | Change |
|
|
|
|
|
|
|
8 | COLOR OFF | Changes the picture | Not change | Change |
|
9 | AREA MARKER | Displays the area marker. | Not display | Display |
|
|
|
|
|
|
|
10 | ASPECT | Changes the screen ratio to 16:9 | 4:3 | 16:9 |
|
11 | TALLY SELECT | Switch the tally lamp color. | GREEN | RED |
|
|
|
|
|
|
|
12 | MARKER | Selects the type of the area marker | Selection in the main unit | Selection in the remote | *2 |
|
|
|
| control |
|
13 | STATUS | Displays the monitor’s status | Display |
| *3 |
|
|
|
|
|
|
14 | REMOTE ENABLE | Makes the external control form the | Invalid | Valid | *4 |
|
| MAKE terminal valid or invalid |
|
|
|
|
|
|
|
|
|
15 | GND | Used as a ground terminal | – | – |
|
|
|
|
|
|
|
*1 : OFF stands for disconnection, and ON stands for
When trigger contact is on, the setting switches between ON and OFF every time the terminal is
*2 : Selects the area marker size from AREA MARKER (setting on the main unit) or AREA
*3 : The STATUS function is activated when the connection to the STATUS terminal is changed (ON to OFF, or OFF to ON). The monitor’s status is displayed for 3 seconds.
*4 : Setting REMOTE ENABLE to ON enables remote control. (same for both MAKE/TRIGGER methods.)
Operation
1.Set REMOTE ENABLE to ON.
2.
Changing the Signal Input
1.Set REMOTE ENABLE to ON.
2.
3.Disconnect the INPUT terminal selected above. The signal input is actually changed after the disconnection has been completed.
NOTES: • When more than two terminals are selected
To control INPUT A through INPUT F, we recommend using the interlock switch, which turns off a switch when another switch is turned on.
•When trigger contact is on, and if several terminals are
20