Bosch Appliances D9210C manual # REXShunt Only?

Page 11

Access Control Interface Module

Strike Profile en 11

 

 

Yes Programmed shunt time will activate so door can be manually opened.

No Request to Enter [RTE] automatically activates the programmed strike and shunt time.

NOTICE!

Use this parameter when a user can open a door manually without relying on a token/card to activate the strike (such as with a “push bar”).

NOTICE!

When RTE Shunt Only is [Yes] Request To Enter events are not logged, reported, or printed.

D# REXShunt Only?

Default:No

Selections:

Yes or No

 

 

Use this program item to disable the strike, but still activate the programmed shunt time upon a Request to Exit an area.

Yes Programmed shunt time will activate so door can be manually opened.

No Request to Exit [REX] automatically activates the programmed strike and shunt time.

NOTICE!

When REX Shunt Only is [Yes] Request To Exit events are not logged, reported, or printed.

Bosch Security Systems, Inc.

Program Entry Guide

F.01U.201.526 02 2011.10

Image 11
Contents Access Control Interface Module Page Table of Contents Other Lettering Conventions used in this document 1TrademarksAbout This Document # CC# Scope Door ProfileDoor # # Entry Area ## Interlock Point # Door Point# Disarm On Open? # Auto Door?# Fire Unlock? En Door Profile Access Control Interface Module # Buzz Time Strike Profile# Strike Time # Shunt Time# RTEShunt Only? # Extend Time# Deact On Open? # REXShunt Only? # No Entry? # Access Granted?Event Profile # Exit Request? # Enter Request?1Notes Door # Point #Point TextLocation 5Program Record SheetsSummary account information Yes/No DoorPage Bosch Security Systems, Inc