Bosch Appliances D9210C manual 1Trademarks, About This Document

Page 4

4

en Trademarks

Access Control Interface Module

 

 

 

1Trademarks

About This Document

This document describes the parameters available to the security panel for programming the D9210C Access Control Interface. For a description of the theory of operation and the actual operation of the unit, please refer to the D9210C Operation and Installation Guide (P/N:

F01U215244).

NOTICE!

References made to the “D9412 Family” will reflect the following product offerings:

D9412GV4, D9412GV3, D9412GV2, D9412G, D9412.

NOTICE!

References made to the “D7412 Family” will reflect the following product offerings:

D7412GV4, D7412GV3, D7412GV2, D7412G, D7412.

This document follows the organization of the RADXAXS handler in the D5200 Programmer (for GV3 Series v8.0x, GV2 Series, and G Series Control Panels) or RPS (Remote Programming Software). Use the ACCESS Control Interface Module Program Record Sheet (P/N: F01U201528) to record your choices prior to programming the device. Each programming section, program item, and its page number are listed in the table of contents on the following page.

Throughout this document, programming prompts are shown in bold italic letters when they are used in a sentence. For example, Door # is the first programming prompt in the DOOR PROFILE section of the program. Reference to handlers, modules, categories and sections of the program are shown in italic, capital letters.

For a more complete understanding of the panel and the D9210C Access Control Interface, read the following in addition to this program entry guide:

D9210C Operation and Installation Guide (P/N: F01U215244)

Security System Owner’s Manual

Security System User Guide

Other Lettering Conventions used in this document

D6600 Security Receiver and local printer reports are shown in typewriter -style letters. For example: ACCESS GRANTED indicates the report sent when the Access Control Interface detects a valid card read.

Generally, words shown in all capital letters with brackets indicate command center displays and command center keys. For example, [ESC] is a key on the command center. Depending on the context of the sentence, all capital letters may also indicate a recommended programming selection.

Reading Bosch Security Systems, Inc. Product Date Codes For Product Date Code information, refer to the Bosch Security Systems, Inc. Web site at: http:// www.boschsecurity.com/datecodes/.

F.01U.201.526 02 2011.10

Program Entry Guide

Bosch Security Systems, Inc.

Image 4
Contents Access Control Interface Module Page Table of Contents About This Document 1TrademarksOther Lettering Conventions used in this document Door Profile Door ## Entry Area # # CC# Scope# Door Point # Interlock Point# Fire Unlock? # Auto Door?# Disarm On Open? En Door Profile Access Control Interface Module Strike Profile # Strike Time# Shunt Time # Buzz Time# Deact On Open? # Extend Time# RTEShunt Only? # REXShunt Only? Event Profile # Access Granted?# No Entry? # Enter Request? # Exit Request?1Notes Summary account information 5Program Record SheetsDoor # Point #Point TextLocation Door Yes/NoPage Bosch Security Systems, Inc