Content of PRGS430.ini File
2.2.4Content of PRGS430.ini File
The last settings of the PRGS430 graphical user interface (GUI) are stored in the .ini file before exiting the program. This information is stored under the Program Device System section.
Additionally, the following parameters are in the [Options] section and may be modified:
[Options]
\BlowFuse = 1 → The blow fuse button in the GUI is disabled to prevent accidental blow of the irreversible fuse.
LastResult = 0 → If the program is called with
2.2.5Use of a [Project].ini File
Some default options could be changed within a [Project].ini file. This file has to be in the same directory as the object code file. The following variables could be defined or redefined there.
The name of the file should have the same name as the object file with the extension .ini.
[ProgramDevice] UserMemProtect = Start, Size UserMemProtect2 = Start, Size UserMemProtect3 = Start, Size UserMemProtectn = Start, Size DisableTIMemProtect = 0
Memory ranges defined in the UserMemProtect and UserMemProtect [n] option are read out and reprogrammed after erase (flash device only). [n] could be a number ≥2 and be in ascending order.
If a memory protection is activated in the device definition file from Texas Instruments, it could be switched off with the DisableTIMemProtect = 1 option.
Operation2-9