Texas Instruments MSP430 manual EVM Warnings and Restrictions

Page 3

EVM WARNINGS AND RESTRICTIONS

It is important to operate this EVM within the specified input and output ranges described in the EVM User’s Guide.

Exceeding the specified input range may cause unexpected operation and/or irreversible damage to the EVM. If there are questions concerning the input range, please contact a TI field representative prior to connecting the input power.

Applying loads outside of the specified output range may result in unintended operation and/or possible permanent damage to the EVM. Please consult the EVM User’s Guide prior to connecting any load to the EVM output. If there is uncertainty as to the load specification, please contact a TI field representative.

During normal operation, some circuit components may have case temperatures greater than 60°C. The EVM is designed to operate properly with certain components above 60°C as long as the input and output ranges are maintained. These components include but are not limited to linear regulators, switching transistors, pass transistors, and current sense resistors. These types of devices can be identified using the EVM schematic located in the EVM User’s Guide. When placing measurement probes near these devices during operation, please be aware that these devices may be very warm to the touch.

Mailing Address:

Texas Instruments

Post Office Box 655303

Dallas, Texas 75265

Image 3
Contents User’s Guide Evaluation BOARD/KIT Important Notice EVM Warnings and Restrictions Page About This Manual Read This FirstFCC Warning Contents Tables FiguresInstallation and Setup −1. ADT430 Program Icons Installing the SoftwareMSP−PRGS430 Installing the HardwarePage Operation Software/Hardware Layers of the PRGS430 Environment Programming MSP430 Devices With the GUI Basic Procedure−1. MSP430 Function Buttons and Descriptions Description of the MSP-PRGS430 GUIOperation2-5 −2. Communication Error Box Error Messages−5. Data Error −2. Error Messages Use of a Project.ini File Content of PRGS430.ini FileGeneral Definitions Command Line OptionsExample Return Values/Error Codes in .ini File FN0003/ SetDeviceType PRGS430.DLL-DescriptionFN0001/ InitCom FN0002/ ReleaseComFN0004/ InitTarget FN0005/ ReleaseTargetFN0006/ Erase FN0008/ EraseCheck FN0007/ EraseFileFN0009/ EraseCheckFile FN00010/ PatternCheckFN00011/ VerifyData FN00012/ VerifyFile FN00013/ VerifyFileRangeFN0014/ ProgramData Pgmwitherasecheck FN0015/ ProgramFileFN0016/ BlowFuse FN0017/ SetVccFN0018/ ReadOutData FN0019/ ReadOutFile FN0020/ ResetFN0023/ GetDeviceCfgInfo FN0022/ SetNotificationWndFN0024/ AccessSFR Status Return Value Comment Return Values/Error Codes From PRGS430.DLLPage Hardware Basic Hints Specifications−1 -Pin Sub-D at Programming Adapter Programming Adapter Target Connector Signals−2. Target Connector Signal Functions Location of Components − MSP-PRGS430 MSP-PRGS430 Circuit DiagramsInterconnection of MSP-PRGS430 to OTP/EPROM-Based Interconnection of MSP−PRGS430 to Flash-Based MSP430 Devices Page Hex Object Format Figure A−1. Intel-Hex Object Format Intel-Hex Object FormatTI-TXT File Format Page Schematics Page Schematics B-3 Page Important Notice
Related manuals
Manual 138 pages 30.24 Kb