■ NETWORK (LAN SETUP)

This screen allows you to set the settings necessary when the monitor is connected to a LAN.

DHCP CLIENT

If your LAN has a DHCP server and you wish to obtain an address automatically, change this setting to “ON”.

To set the address manually, set this to “OFF”.

IP ADDRESS

If the DHCP CLIENT is set to “OFF”, specify an IP address.

SUBNET MASK

If the DHCP CLIENT is set to “OFF”, specify the subnet mask.

DEFAULT GATEWAY

If the DHCP CLIENT is set to “OFF”, specify the default gateway.

If you are not using a default gateway, specify “0.0.0.0”.

DNS SERVER

Specify the DNS server address.

If you are not using a DNS server, specify “0.0.0.0”.

RESET

Clicking [Execute] returns all of the LAN SETUP settings to the factory-preset values except for the DNS SERVER setting.

TIPS

When the IP address is set manually, the IP addresses of the monitor connected to the RS-232C output terminal and the daisy chain of connected monitors that follows can be assigned automatically. (See page 22.)

Controlling the Monitor with a PC (LAN)

■ NETWORK (SECURITY)

This screen allows you to specify the security-related settings.

USER NAME / PASSWORD

Sets up a user name and password to restrict access to this monitor.

After entering a user name and password, click [Apply].

ACCEPT IP ADDRESS

You can limit access to this monitor by registering IP addresses of PCs that should have access.

To limit access, specify the option “From only specific IP addresses”. Otherwise, to allow access from any PC, specify “All IP Addresses”.

IP ADDRESS 1 to 3

If “ACCEPT IP ADDRESS” is set to “From only specific IP addresses”, enter the IP addresses that you want to allow.

TIPS

The USER NAME and PASSWORD can be up to 8 alphanumeric characters or symbols.

To cancel the user name and/or password after it has been set, make the box empty and click [Apply].

45 E

Image 45
Contents PN-E802 A. only Model No Serial NoImportant Information Refer Servicing to Qualified Service PersonnelDear Sharp Customer Safety Precautions Tips and Safety Instructions For the monitor in landscape orientation For the monitor in portrait orientationDo not place the monitor on a device which generates heat Supplied Components ContentsNFront view Part NamesPart Names NRemote control unit Signal transmitterPower button See Mute button See Connecting Peripheral Equipment 11 EConnection with a PC or AV equipment Connecting Peripheral Equipment Binding Cables Connecting the Power CordRemoving the Handles 13 EInstalling the batteries Preparing the Remote Control UnitRemote control operation range 16.4Turning on the main power Turning Power On/OffTurning power on/off 15 ETurning Power On/Off NDate/time setting Disabling power on/off operations17 E Basic OperationMute MenuWide Zoom Normal Basic Operation NSwitching the screen sizeDot by Dot Cut offMenu Items 19 EDisplaying the menu screen Menu Items Menu item detailsNSCREEN NPICTUREMenu Items NSETUP 21 ENAUDIO NOPTION Menu Items NMULTI 23 ENDual screen display Menu Items NPIP/PbyPSetting procedure Menu Items NZOOM2 Special Setting25 E NEnlargeMenu Items NSCHEDULE PowerDAY of the Week InputNAutomatic adjustment Adjustments for PC screen displayNScreen display for adjustment 27 EAdjustment Lock ALL ResetAdjustment Lock Target Temperature AlertControlling the Monitor with a PC RS-232C Communication procedure29 E PC connectionNID numbers NCommunication intervalWait ← 31 ESetting of the Gamma user data Power control/Input mode selection RS-232C command tableHow to read the command table 33 EControlling the Monitor with a PC RS-232C Screen menu Controlling the Monitor with a PC RS-232C Picture menu 35 EControlling the Monitor with a PC RS-232C Audio menu Setup menuControlling the Monitor with a PC RS-232C Option menu 37 EImage Position Epos setting Controlling the Monitor with a PC RS-232C Multi menuLandscape orientation Portrait orientation Initialization/Functional Restriction Setting Function menu 39 EControlling the Monitor with a PC RS-232C PIP/PbyP menu Controlling the Monitor with a PC RS-232C Others Commands for setting of the Gamma user dataControlling the Monitor with a PC LAN Settings to connect to a LAN41 E To set on the monitorControlling the Monitor with a PC LAN To set from a PC Default Gateway 0.0Controlling with a PC 43 EControlling the Monitor with a PC LAN Basic operationInformation about this monitor appears Standby mode, Power on is the operation available45 E User Name / PasswordDNS Server Accept IP AddressAuthentication Installation Information NAME/LOCATIONAccount Name / Password Monitor NameRecipient E-MAIL Addresses 47 ECondition ConfirmationTrap Setting Snmp SettingTrap Setting of Authentication Error Version49 E TroubleshootingTroubleshooting Specifications NProduct Specifications51 E NPower management Specifications NDimensional DrawingsDmpm Digital Monitor Power Management NDDC plug and playSpecifications NCompatible signal timing PC NCompatible signal timing AV53 E NPC D-sub input terminal pins Specifications NPC/AV DVI-D input terminal pinsNPC/AV DVI-D output terminal pins NPC/AV Hdmi input terminal pins55 E Secure using 2 cover screws M4 with washers suppliedPN-E802 Mu EN12D1

PNE802, PN-E802 specifications

The Sharp PN-E802 and its variant, PNE802, represent the pinnacle of professional display technology, designed to meet the demanding needs of various commercial environments. With a massive 80-inch diagonal screen, these displays offer an immersive visual experience, making them ideal for use in meeting rooms, conference halls, retail spaces, and control rooms.

One of the key features of the Sharp PN-E802 is its 4K Ultra HD resolution, providing stunning clarity and detail. With a resolution of 3840 x 2160 pixels, images and text appear razor-sharp, allowing viewers to see every detail, which is essential for presentations and video content. The widescreen aspect ratio enhances the cinematic experience, ideal for videos and detailed graphics.

Equipped with advanced LCD technology, the PN-E802 showcases vibrant colors and deep blacks, further enhanced by Sharp's proprietary UV2A technology. This technology improves color accuracy and enhances brightness, ensuring that images remain vivid even in well-lit environments. The display supports a wide color gamut, encompassing a broader range of colors to produce more accurate and lifelike images.

Moreover, the PN-E802 boasts an integrated digital signage function, making it suitable for dynamic content displays. Users can easily manage and update content via a USB connection, allowing for seamless integration into existing systems. This feature is particularly useful for businesses that need to display rotating advertisements or informational content.

Another noteworthy characteristic of the Sharp PN-E802 is its robust build and reliability. Designed for 24/7 operation, this display can withstand constant use without compromising performance. It also features a sleek design, making it an aesthetic addition to any corporate or public space.

Finally, connectivity options abound with the PN-E802, including multiple HDMI, DisplayPort, and DVI inputs, allowing for a versatile array of connection types. This ensures compatibility with various devices, from computers to media players, making installation and integration into existing AV systems straightforward.

In summary, the Sharp PN-E802 and PNE802 models are high-performance displays that combine advanced technology, exceptional image quality, and versatile functionality, making them an excellent choice for any professional setting. Whether for presentations, signage, or collaborative work, these displays deliver an unparalleled viewing experience that stands out in any environment.