TANDBERG MPS 200, MPS 800 Precautions, Unpacking and Mounting, What is in the Box?, Rack Mounting

Page 20

Installation

Precautions, Unpacking and Mounting

TANDBERG MPS ADMINISTRATOR GUIDE

Precautions

Please read carefully:

Never install communication equipment dur- ing a lightning storm.

Never install jacks for communication cables in wet locations unless the jack is specifically designed for wet locations.

Never touch uninstalled communication wires or terminals unless the communication line has been disconnected at the network interface.

Use caution when installing or modifying com- munication lines.

Avoid using communication equipment (other than a cordless type) during an electrical storm. There may be a remote risk of electri- cal shock from lightning.

Do not use communication equipment to report a gas leak in the vicinity of the leak.

The socket outlet shall be installed near the equipment and shall be easily accessible.

Never install cables without first switching the power OFF.

This product complies with directives: LVD 73/23/EC and EMC 89/366/EEC.

Caution - Double pole fusing.

Power must be switched off before power supplies can be removed from or installed into the unit.

What is in the Box?

Unpacking

To avoid damage to the unit during transportation, the TANDBERG MPS is delivered in a special shipping box.

The shipping box contains the following components:

1.Chassis:

a.MPS 200, a 3U chassis with power supply.

b.or MPS 800, a 9U chassis with 2 or 3 x Power Units (depending on the number of Media Processing Boards installed)

c.1 x System Controller Board

d.The Media Processing Boards ordered

e.PRI E1/T1 ISDN Interface Card (if ordered)

f.V.35 Serial Interface Card (if ordered)

2.Administrator Guide and other documentation on CD

3.Installation sheets

4.4 screws and 4 nuts for rack mounting and 4 pads

5.Cables:

a.Power cable

b.Ethernet cables

c.ISDN cables (optional)

d.V.35 kit (optional). The kit includes cables that convert from high- density connectors on V.35 card to TANDBERG’s standard V.35 connectors (26pin DSUB) and 19” rack-mountable panel where the V.35 connectors will fit.

e.RJ45 to RS-232 converter cable

Rack Mounting

Preparations on Site

The mounting space must be prepared before you start:

Make sure the TANDBERG MPS is accessible and that all cables can be easily connected

For ventilation: Leave a space of at least 10cm (4 inches) behind the TANDBERG MPS’s rear panel and 10cm (4 inches) in front of the front panel

The room in which you install the TANDBERG MPS should have an ambient temperature between 0ºC and 35ºC (32ºF and 95ºF) and between 10% and 90% non-condensing relative humidity

Do not place heavy objects directly on top of the TANDBERG MPS

Do not place hot objects directly on top, or directly beneath the

TANDBERG MPS

Use a grounded AC power outlet for the TANDBERG MPS.

Mounting the MPS on a Rack

The TANDBERG MPS comes with 4 screws and 4 nuts for mounting in standard 19” racks. The chassis is equipped with brackets.

1.Before starting the rack mounting, please make sure the TAND- BERG MPS is placed securely on a hard, flat surface.

2.Disconnect the AC power cable.

3.Make sure that the mounting space is according to the Prepara- tions on Site in the section above.

4.Insert the chassis into a 19” rack, and secure with screws in the front (four screws) and nuts (four nuts).

Main

Table of

Introduction

Installation

Quick

Using

System

System

Gateway

MCU

Technical

Appendices

Contents

Setup

the MPS

Status

Configuration

Configuration

Configuration

Descriptions

 

 

 

 

D 13373.08

 

 

 

 

 

20

 

 

 

 

MPS

NOVEMBER 2007

 

 

 

 

 

 

 

 

 

Image 20
Contents MPS 200 MPS Finding the Information You Need What’s in this Administrator Guide? Finding the Information You Need IntroductionTable of Contents Introduction New Features in Version J4 What’s New in this Version?Disclaimer Patent informationLicense Agreement Trademark and CopyrightThird Party Software, Licenses and Copyright Third Party SoftwareLicense for openssh Portable OpenSSH contains the following additional License for Less BSD License for zlib Safety Instructions Administrator GuideEnvironmental Issues TANDBERG’s Environmental PolicyEnvironmental Issues RoHS Table China RoHS TableFeatures Overview & MPS Capacity MPS ModelsTandberg MPS at a Glance Rack Mountable ChassisRear View Front ViewInstallation Precautions, Unpacking and Mounting PrecautionsWhat is in the Box? Rack MountingMPS 200 with 2 Media Processing Boards Front Side Media Processing Boards System Controller Board in slotMPS 200 with Isdn and V.35 Network Cards Rear Side Serial 3/4Module System Controller Board SerialMPS 800 with 8 Media Processing Cards Front Side System Controller Board in slot Media Processing Boards2Power Supply units hot swap MPS 800 with Isdn and V.35 Network Cards Rear SideConnecting Ethernet Cables Connecting CablesConnecting Cables Starting the System Starting the SystemLCD Menu Structure LCD Menu StructureLCD Menus Parameter Configuration System Controller Board Parameter ConfigurationInitial Configuration Media Processing Board Parameter Configuration Quick Setup of the MPS Using the Web Interface User Interfaces for the MPSUser Interfaces for the MPS OverviewSimple IP Configuration Simple IP ConfigurationConfiguration of the MPS using Web Interface Configuration of the System Controller BoardSimple H.323 Configuration Simple H.323 ConfigurationRegistration to a Gatekeeper Enter the Gatekeeper IP AddressSimple PRI Configuration Simple PRI ConfigurationSimple PRI Configuration Dial In Configuration Simple Dial In ConfigurationSimple Dial In Configuration Using the MPS MCU Usage Information MCU Usage InformationFilter Conference Overview MCU Conference OverviewMCU Conference Overview Setting Up a MCU Conference Create ConferenceConference Configuration Maximum Call Duration Legacy LevelFloor to Full Screen Billing CodeShow Current Speaker Video SettingsConference Layout CP Autoswitching Create Only Add Participants CancelVideo Format Video Custom FormatsLecture Mode Dual Video StreamConference Selfview Telephone IndicationParticipant Identifier Timeout Participant IdentifierChair Control Minimum Bandwidth TresholdOptimal Voice Switch Encoder Selection PolicySecondary Rate Web SnapshotsAudio Settings Password Out Security SettingsPassword Encryption Mode Protected Numbers in the Dial In ConfigurationEncryption ProtectParticipants Settings Network Settings Manage an Active Conference Manage an Active ConferenceConference Status Encryption / Password Conference ModeParticipants Conference SnapshotAdd Participants Second Number Add Participants 23 Manual DialingCall Type Add Participants 33 Manual Dialing Add Participants Examples Example 1 H.323 / IP H.323 IDExample 2 H.323 / IP IP Address Example 3 Isdn Example 4 G.703 Leased LineRead More Edit Conference SettingsConference Configuration Protected Numbers Using Dial In Direct NumbersDial In Direct did Basic View Picture VideoDual Video Stream DuoVideoTF/H.239/BFCP Actions Audio Input LevelAdvanced View Advanced ViewPaticipant Info Call InfoHow to Initiate Cascaded Conference Terminal List ViewTerminal List MCUs in CascadeChange View Gateway Features and Capacity Gateway Features Gateway CapacityGateway Usage Information Gateway Usage InformationGateway Calls Overview Gateway Calls OverviewDisconnect a Call Disconnect a Gateway CallH.323 Call Transfer window will be shown Transfer a CallTransfer a Gateway Call Phone Book Phone Book MainNetwork Module Cancel Add New EntryNetwork ID Create New Select Create New toEdit Entry Network ID SaveCreate New Cancel Add New Group EntryGroup Entry AddSystem Status Isdn PRI Board Status Isdn PRI Board StatusIsdn PRI Board Status Most common cause codes for IsdnBoard Status Board StatusBoard Status Serial V.35 Board Status Serial V.35 Board StatusSerial V.35 Board Status Media Board IP Status Media Board IP StatusGatekeeper Status StatusStatus SIP Status SIP StatusServer Status RegistrationSystem Unit, Software, Configuration, Managed Resources System InformationMCU, Gateway, Hardware MCU ResourcesTotal Gateway Resources HardwareUsed Resources TotalGateway EthernetsSystem Configuration Network Configuration Network ConfigurationPRI Board in Slot 1-n Send CompleteSend Number Parallel DialSpeech Timers NSF Telephony ModeNSF Video Mode NSF Telephony NumberAlert Trunk GroupsInitial Restart PRI Interface Configuration PRI InterfacesNumber Range Start Number Range StopNfas Interface ID Allow NfasNfas Group ID E1/T1 Interface Configuration Network ConfigurationE1/T1 Interfaces T1 Cable LengthEnable Board InterfacesTion Board Physical LayerCalls Channel 1 toStart Channel 1 to Max Channels 1 to IP Interfaces Configuration IP Configuration Interface 1Address Subnet MaskDNS Interface 1 DNS Interfaces, IP ServicesIP Services Media Board Configuration Slot 1 to n Media Board IP ConfigurationMedia Board IP Configuration 100 Serial V.35 Board InterfacesGatekeeper Settings, Net 101Snmp Configuration 102SIP Configuration 103QoS Quality of Service Configuration 104105 Miscellaneous ConfigurationMiscellaneous Configuration Software Upgrade Software Upgrade106 Important Before UpgradingSet Language Language Configuration and File Management107 108 Dialog PicturesFile Management Dialog PicturesDialog Sounds, Symbols Symbols109 Dialog SoundsConfiguration Using XML Using the XML Document110 XML Document111 Certificate ManagementCertificate Management Manage CertificatesGateway Configuration 112113 Gateway Functionality and Dialling RulesGateway Functionality About Dialling RulesSetting up Dialling Rules 114Dialling Rules Handling Dialling Rules115 Examples with Isdn Gateway116 Examples with V.35 GatewayAbout V.35 Ports Example 1 did117 Examples with G.703 GatewayAbout G.703 Ports Example 1 did Example 2 did Example 3 didGateway Configuration 118Interoperability Natural VideoExternal Crypto Device 119H.323 120 264Percent of Total Bandwidth Load LimitLegal File Formats 121File Management MCU Configuration 122About the Dial In Numbers Menu 123About the Dial In Numbers Menu 124 Single Dial In Number MenuAbout Single Dial In Number MenuAd Hoc Conferences 125Ad Hoc Conferences Menu Static Conferences 126Static Conferences Menu Personal Conferences 127Personal Conferences Menu Password Protection No Password Protection128 Edit ParticipantsDirect Ad Hoc Conferences 129Direct Ad Hoc Conferences Menu Network Profiles 130Network Profiles 131 Conference Template ConfigurationConference Template Configuration Conference Templates are found in the MCU Configuration tab 132133 134 Video Format135 136 137 Force Aspect Ratio138 139 140 141 Entry and Exit Tone142 143 144 145 Technical Descriptions146 System Controller Board InterfaceChassis System Controller Board Interface Serial Port Pinout COM1 Pinout147 Media Processing Board InterfaceChassis Advanced Video Option148 E1/T1 Network Interface Card IIC-8E1/T1 Network Interface Card IIC-8 PRI E1/T1 PinoutChannel Service Unit 149LED’s for the E1/T1 PRI Interface Card IIC-8 PRI ProtocolsAT&T Service Code Ref.1 Sprint Service Code Ref.2150 PRI T1 US onlySerial Interface Card SIC-32 151Serial Interface Card SIC-32 Pair no Plug C Plug a Signal Name Plug B 152Serial Interface Card Cable Description Serial Interface Cable DescriptionPower Supplies Power Supply Tandberg MPSPower Supply for Tandberg MPS 153154 MPS 800 Inserting Network Interface CardsPRI E1/T1 Isdn Interface Card Serial Interface Card155 MPS 200 Inserting Network Interface Cards156 Quality of Service QoSQuality of Service Feature QoS Video Features 157Optimal Voice Switch 158Flow Control DownspeedingTF Other Features159 Intelligent Packet Loss Recovery 160Inband Changing of Video and Audio Algorithms Transcoding and RatematchingFeatures Supported Administrator Features Supported161 Distributed MCUs162 Ports and Packet SizesSecure Conference Encryption 163Secure Conference Encryption 164 System Management ToolsSystem Management and Security Disable Services Secure Shell SSH Security Alert165 166 Appendices167 Tandberg MPS 200168 Network Interfaces169 Tandberg MPS 800170 171 Product Approvals and DeclarationsProduct Approvals Class Product DeclarationCurrent RFCs and Drafts Supported 172SIP Current RFC’s and Drafts Supported Configuring LCS and MPS for SIP Configuring LCS and MPSConfiguring LCS 173174 Login and Locate the ServerSelect the Host Authorization tab Set Transport to TCP Set Port to Example #1 175Add a Route MPS DNS Configuration Configuring the MPSDNS Server Configuration DNS ConfigurationMPS SIP Configuration SIP ConfigurationSet SIP Mode to On 177178 Verify the ConfigurationConfiguring SIP Dial In Numbers European Headquarters
Related manuals
Manual 2 pages 38.4 Kb

MPS 800, MPS 200 specifications

The TANDBERG MPS 200 is an advanced multipoint conferencing solution designed to enhance communication and collaboration in various environments. Renowned for its robust performance and versatile features, the MPS 200 caters to businesses and organizations seeking to integrate video conferencing seamlessly into their operations.

One of the standout features of the MPS 200 is its ability to support high-definition video conferencing. Ensuring crystal-clear imagery, it accommodates various video standards, including H.264, allowing for efficient bandwidth usage without compromising quality. This makes it an excellent choice for organizations that require high-quality video for their meetings, presentations, or training sessions.

The MPS 200 also supports a wide range of participants, facilitating large-scale conferences with multiple endpoints. It can connect numerous participants simultaneously, allowing teams from different locations to collaborate effectively. This scalability is essential for businesses that frequently host meetings with various stakeholders, enabling seamless interaction and engagement.

Another noteworthy technology integrated into the MPS 200 is its flexibility in connectivity. It supports a variety of protocols, including SIP and H.323, ensuring compatibility with existing infrastructure. This flexible design allows organizations to integrate the MPS 200 into their current systems with minimal disruptions, making it an attractive option for businesses looking to upgrade their conferencing capabilities.

In addition to video conferencing, the MPS 200 offers features such as content sharing, which enables users to share documents, presentations, and other materials during meetings. This functionality enhances collaboration by allowing participants to view and discuss content in real-time, fostering engagement and ensuring that everyone remains on the same page.

The user interface of the MPS 200 is designed for ease of use, providing intuitive controls that facilitate quick setup and management of conferences. Users can initiate or join meetings with just a few clicks, ensuring that technology does not hinder productivity.

Security is a priority with the MPS 200, which incorporates various encryption methods to protect sensitive information during video calls. With security becoming increasingly important in today’s digital landscape, this feature offers peace of mind to users, particularly in enterprise environments.

In summary, the TANDBERG MPS 200 stands out as a comprehensive multipoint conferencing solution that delivers high-quality video, extensive connectivity options, and advanced collaboration features. Its user-friendly design, scalability, and robust security measures make it a vital asset for organizations aiming to enhance their communication strategies in the digital age. Whether for internal meetings or external engagements, the MPS 200 serves as an indispensable tool for effective collaboration.