TANDBERG D14129.02 manual Video output formats, DIP switch settings for video output formats

Page 37

Codec C90

Contents

Introduction

Getting started

Video output formats

This section describes the video output formats for the TANDBERG PrecisionHD 1080p camera.

DIP switch settings for video output formats

Administrator Guide

About the menus

About the settings

Settings Library

 

Camerasa eras

Appendices

Contact us

 

 

 

 

 

 

 

The video output format for the camera is set by DIP switches. The DIP switches are found on the bottom side of the camera.

The default setting is Auto. When using HDMI, the video output format is automatically detected. See the table to the right.

Maximum resolution for HDMI is 1080p60. Maximum resolution for HD-SDI is 1080p30.

Line voltage frequency

The camera will automatically detect the line voltage frequency when it is 50 or 60 Hz. You may set the video output format to a specific value (use the DIP switches) to override the auto frequency detection, if a different line voltage frequency is an issue.

1

0

The DIP switch

Bottom side of the TANDBERG PrecisionHD 1080p camera

DIP Switch table for video formats

1

2

3

4

5

HDMI

 

HD-SDI

 

 

 

 

 

 

 

 

0

0

0

0

0

 

Auto

 

 

 

 

 

 

 

 

0

0

0

0

1

1920x1080p25

 

1920x1080p25

 

 

 

 

 

 

 

 

0

0

0

1

0

1920x1080p30

 

1920x1080p30

 

 

 

 

 

 

 

 

0

0

0

1

1

1920x1080p50

 

1280x720p50

 

 

 

 

 

 

 

 

0

0

1

0

0

1920x1080p60

 

1280x720p60

 

 

 

 

 

 

 

 

0

0

1

0

1

1280x720p25

 

1280x720p25

 

 

 

 

 

 

 

 

0

0

1

1

0

1280x720p30

 

1280x720p30

 

 

 

 

 

 

 

 

0

0

1

1

1

1280x720p50

 

1280x720p50

 

 

 

 

 

 

 

 

0

1

0

0

0

1280x720p60

 

1280x720p60

 

 

 

 

 

 

 

0

1

0

0

1

Software control

 

 

 

 

 

 

 

 

The table shows the different settings available for the HDMI and the HD-SDI outputs.

Auto: Camera negotiates format over HDMI. HD-SDI tracks HDMI and defaults to 1080p30 in absence of HDMI sync.

Software: For more on the Software control setting, read about video mode selections in the TANDBERG PrecisionHD 1080p User Guide.

D14129.02—NOVEMBER 2008

37

Image 37
Contents Tandberg Codec C90 What’s in this guide? Table of ContentsChapter IntroductionThis chapter Trademark Intellectual Property RightsDisclaimer Patent InformationWater and Moisture Safety InstructionsTANDBERG’s Environmental Policy Environmental IssuesGetting started Optional Assemble your systemBatteries Using the Remote ControlCall KEY Using the Remote Control,Turn on the system Verify IP address settingsIf you need to set a static IP address Time zone settings Verify your settingsAdd the system to the network Main monitor About main and dual monitorsDual monitors About the menus Administrator settings menu Settings The Settings menuAbout the menus Home The Home menuSettings menu IP Settings menu Administrator settingsSearch Advanced configuration menuAdministrator Settings Library Audio settings Description of the administrator settingsAudio Output Line 1. Mode On/Off Audio Output Hdmi 1, 3 Mode On/OffAudio Input Line 1. Level Audio Input Line 1. Channel Left/Right/MonoCamera settings Conference settings Do not disturb setting H323 Profile settingsNetwork settings Network services settings NetworkServices Snmp CommunityName S 0 NetworkServices Snmp Mode Off/ReadOnly/ReadWriteNetworkServices Snmp SystemContact S 0 NetworkServices Snmp SystemLocation S 0Provisioning settings Phone book server settingsSerial port settings Standby settings SIP Profile settingsTime zone setting System unit settings Video settingsVideo Input Source 2 Connector HDMI/HDSDI/YPbPr Video OSD Mode On/OffVideo Input Source 1. CameraControl Mode On/Off Video Input Source 1 Connector HDMI/HDSDI/YPbPrExperimental menu Video Output Composite 5 Resolution PAL/NTSCCameras Hdmi and HD-SDI PrecisionHD 1080p cameraKensington lock Cascaded camerasHdmi cable Connecting the cameraHD-SDI cable Hdmi to DVI-D adapterBest view-Face recognition Using Best viewVideo output formats DIP switch settings for video output formatsLine voltage frequency Cameras in daisy chain Appendices Physical conditions General room guidelinesRoom equipment Environmental considerationsNatural communication Audio qualityBest audio quality to all participants Making eye contactGeneral recommendations for the room layout Guidelines for the executive meeting roomShows the PC presentation and the participants Sharing a PC presentationOther presentation sources Camera view Guidelines for the high end meeting roomCodec C90 Administrator settings Configure the video inputsAPI commands Video Input MatrixSoftware upgrade procedure Software upgradeHow to upload the certificate Certificates upload procedureUpload certificates Command ConfigurationXML files View XML filesDebug log files Log filesNTP Time Zone expressions NTP Time Zone expressions, GMT+0 Current RFCs and drafts supported in SIP Supported RFCs in SIPMedia capabilities supported in SIP Arrows Tandberg Remote Control TRC5Button codes Remote control TRC5 Tandberg Remote Control TRC5 key mapCascaded cameras PrecisionHD cameraTandberg Precision HD camera Kensington lockEC Declaration of conformity CE Declaration for Codec C90China RoHS table Tandberg Codec C90 dimensions PrecisionHD 1080p camera dimensions PrecisionHD camera dimensions Hdmi inputs, supported formats Technical specificationsISO 9001 certificate is available upon request Headquarters European Headquarters Tandberg