5 DIP SWITCH FOR FUNCTION SELECTION ON CCU-11BThe DIP switches on the CCU-11B allow selection of the following functions;

A.

All Call Paging and Response

E.

PTT Control

B.

Call Holding/Call Transfer

F.

Priority and Executive Priority

C.

Calling Tone Duration

G.

Remote Control

D.

Time Interval Adjustment before All Call Paging

H.

Continuous Calling Tone

Switches

Functions

DIP-SW "ON "Position

DIP-SW "OFF "Position

1: BATT. OFF

Mini-Jumper for Battery

Battery "ON"

Battery "OFF"

2: BATT. ON

Position

Position

 

 

 

 

OFF

 

 

 

OFF

 

 

 

Remote Control (Door)

Make/Break Relay Output

One shot Relay Output

SW-A (SW2)

 

 

(4sec.)

 

 

 

 

Continues Calling Tone

Activate

Not Activate

 

OFF

 

 

 

OFF

 

 

SW-B (SW1)

OFF

PROG

ON sw

Priority & Executive Priority

Press to Talk Control

Time Interval Adjustment before All Call Paging Pre- announce Tone

Calling Tone Duration

CallTransfer

All Call Paging & Response

Programming Switch

Activate

Not Activate

Activate

Not Activate

1 ~ 2 sec.

None

Short (0.7 sec)

Long (1.3 sec)

Activate

Not Activate

Activate

Not Activate

Station No. 11 is

Station No. 11 is a

"Programming station'

normal station

— 5 —

Image 6
Contents TOA EXES-1000 Intercom System Contents Functions Which Require Additional Units Unit Model No Remarks FunctionPrecautions for Installation of CCU-11B Program Switch for No ProgrammingConfirmation tone Initial CCU-11B SET UPFirst installation? Yes Is Executive Priority necessary?OFF Station no Programming for Each Function Continuously called station numberAscertain holding tone Sub-station Number Sub-station Number SW-A-3 on SW-B-2 OFF Remote Control Relays RY1 & RY2 on CCU-11BSW-A-3 OFF Opening Then touch dialConnections Programming List for Functions Station NoKOBE, Japan