ATEN Technology CS-1016, CS-1004, CS-1008 user manual First Stage Installation

Page 10

Installation

Before you begin, make sure that power to all the devices (Master View Pro and PCs) you will be connecting up have been turned off.

First Stage Installation

In a Single Stage installation, there are no additional Master View’s daisy chained down from the first unit. To set up a single stage installation do the following:

1.Set Switches 1 - 5 of the Master View Pro’s DIP Switch to the ON position to set this unit up as the First Station (see the table on page 26 for Dip Switch Station Setting details).

2.To enable Hot Key port selection (see p.13, for details concerning Hot Key Port Selection), set DIP Switch 6 to the ON position.

3.Plug the monitor, keyboard, and mouse into the Console port connectors located on the right rear panel of the Master View unit. Each port is labeled with an appropriate icon to indicate itself.

4.Use connector cable sets (as described in the Hardware Requirements section), to connect the monitor, keyboard and mouse ports of the PCs to any available Master View CPU Port (CPU1 to CPU16), as shown in the diagram below.

Note: Ignore the Chain In and Chain Out Ports at this time. They are only used when daisy chaining additional Master View Pro units. Daisy chaining is described in the next section.

5.Plug the power adapter into an AC source; plug the power adapter cable into the Master View Pro’s Power Jack.

PS/2 KEYBOARD

PS/2

MOUSE

PORT

PORT

 

VGA MONITOR PORT

PS/2 MOUSE

VGA MONITOR

PS/2 KEYBOARD

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DIP Switch

 

 

 

 

 

 

Power Adapter

 

 

 

 

 

 

 

 

6

 

 

 

 

CS-1004 / CS-1008 / CS-1016 User Manual

 

 

 

 

 

 

 

2001-01-13

 

 

 

 

 

 

 

 

 

Image 10
Contents CS-1004 /CS-1008 /CS-1016 2001-01-13 Packing List Contents Overview Model Computer Ports Maximum via Daisy ChainFeatures Console Connector Type CS Custom CableHardware Requirements CablesUnpacking Power SwitchK/M Reset Port Selection SwitchesPower LED CS-1016 Front ViewCS-1016 Rear View Installation First Stage InstallationDaisy Chaining Turn on the power to the Master ViewPattern Indication PS/2 Mouse Hot Plugging Powering Off and RestartingOperation Hot Plugging CPU PortsHot Key Port SelectionManual OSDPort ID Numbering Numbering RulesPort Numbering is summarized in the following table Port Numbering TableNumber of Digits Meaning Hot Key Operation Hotkey Port SelectionHot Key Broadcasting Previous/Next SwitchingCtrl + Alt + 1 + Enter to initiate the keyboard broadcast OSD Operation NavigationF1 GoTo OSD Main Menu HeadingsFunction Keys Heading ExplanationF3 List F2 ScanChoice Meaning F4 QV F5 NameSetting Function Settings are explained in the table belowF6 Set Factory default settings are as follows Factory Default SettingsSetting Default Password OSD Security FeaturesWhich case you must start again from the beginning Lock/Unlock Console Station Numbering Table AppendixStation Troubleshooting Symptom Possible Cause ActionSpecifications Function CS-1004 CS-1008 CS-1016Limited Warranty Federal Communications Commission Statement