ATEN Technology CS-1004, CS-1016, CS-1008 user manual Appendix, Station Numbering Table

Page 27

Appendix

Station Numbering Table

The first Master View Pro (the one that the console connects to), is considered the First Station; the Master View Pro that daisy chains to it is considered the Second Station; the Master View Pro daisy chained to the Second Station is considered the Third Station, etc. Switches 1 - 5 of the DIP Switch located on the Master View Pro’s rear panel are used to set the Station Number of each daisy chained unit, as indicated in the table below;

(0 = On; 1 = Off):

Station

SW1

SW2

SW3

SW4

SW5

Station

SW1

SW2

SW3

SW4

SW5

1

ON

ON

ON

ON

ON

17

ON

ON

ON

ON

OFF

2

OFF

ON

ON

ON

ON

18

OFF

ON

ON

ON

OFF

3

ON

OFF

ON

ON

ON

19

OFF

OFF

ON

ON

OFF

4

OFF

OFF

ON

ON

ON

20

OFF

OFF

ON

ON

OFF

5

ON

ON

OFF

ON

ON

21

ON

ON

OFF

ON

OFF

6

OFF

ON

OFF

ON

ON

22

OFF

ON

OFF

ON

OFF

7

ON

OFF

OFF

ON

ON

23

ON

OFF

OFF

ON

OFF

8

OFF

OFF

OFF

ON

ON

24

OFF

OFF

OFF

ON

OFF

9

ON

ON

ON

OFF

OFF

25

ON

ON

ON

OFF

OFF

10

OFF

ON

ON

OFF

ON

26

OFF

ON

ON

OFF

OFF

11

ON

OFF

ON

OFF

ON

27

ON

OFF

ON

OFF

OFF

12

OFF

OFF

ON

OFF

ON

28

OFF

OFF

ON

OFF

OFF

13

ON

ON

OFF

OFF

ON

29

ON

ON

OFF

OFF

OFF

14

OFF

ON

OFF

OFF

ON

30

OFF

ON

OFF

OFF

OFF

15

ON

OFF

OFF

OFF

ON

31

ON

OFF

OFF

OFF

OFF

16

OFF

OFF

OFF

OFF

ON

32

OFF

OFF

OFF

OFF

OFF

CS-1004 / CS-1008 / CS-1016 User Manual

23

2001-01-13

Image 27
Contents CS-1004 /CS-1008 /CS-1016 2001-01-13 Packing List Contents Model Computer Ports Maximum via Daisy Chain OverviewFeatures Cables Connector Type CS Custom CableHardware Requirements ConsoleCS-1016 Front View Power SwitchK/M Reset Port Selection SwitchesPower LED UnpackingCS-1016 Rear View First Stage Installation InstallationTurn on the power to the Master View Daisy ChainingPattern Indication PS/2 Mouse Hot Plugging CPU Ports Powering Off and RestartingOperation Hot PluggingOSD Port SelectionManual Hot KeyNumbering Rules Port ID NumberingPort Numbering Table Port Numbering is summarized in the following tableNumber of Digits Meaning Hotkey Port Selection Hot Key OperationPrevious/Next Switching Hot Key BroadcastingCtrl + Alt + 1 + Enter to initiate the keyboard broadcast Navigation OSD OperationHeading Explanation OSD Main Menu HeadingsFunction Keys F1 GoToF2 Scan F3 ListChoice Meaning F5 Name F4 QVSettings are explained in the table below Setting FunctionF6 Set Factory Default Settings Factory default settings are as followsSetting Default OSD Security Features PasswordWhich case you must start again from the beginning Lock/Unlock Console Appendix Station Numbering TableStation Symptom Possible Cause Action TroubleshootingFunction CS-1004 CS-1008 CS-1016 SpecificationsFederal Communications Commission Statement Limited Warranty