ATEN Technology CS-1008 Daisy Chaining, Turn on the power to the Master View, Pattern Indication

Page 11

6.Turn on the power to the Master View.

Note: When you turn the unit On, it undergoes a Power On Self Test. If there is a problem, Port LEDs 1 - 4 flash repeatedly according to a pattern that indicates what the problem is:

 

 

Pattern

Indication

LEDs 1

- 4

Flash Simultaneously

Internal RAM Memory Error

 

 

 

 

LEDs 1

- 4

Flash One After the Other

External RAM Memory Error

 

 

LEDs 1 + 2, and LEDs 3 + 4 Alternately Light and Go Off

ROM Test Error

 

 

 

 

If any of these problems occur, turn the Switch Off, then turn it On again.

7.Turn on the power to the PCs.

Note: You must turn on the power to the Master View Pro before turning on the power to the PCs.

Daisy Chaining

To provide control for more PCs than just a single Master View Pro unit allows, up to 31 additional Master View Pro units can be daisy chained down form the original one. In this way, as many as 128, 256, 512 PCs can be controlled in a complete installation depending on which model your installation uses (CS-1004, CS-1008, or CS-1016, respectively).

Note: While it is physically possible to mix the different Master View Pro models on the same daisy chain, we strongly recommend against it, as doing so can cause problems with Hot Key and OSD port switching. Please use all of the units of the same model when daisy chaining.

The first Master View (the one that the console connects to), is considered the First Station; the Master View that daisy chains to it is considered the Second Station; the Master View daisy chained to the Second Station is considered the Third Station, etc. To daisy chain a Master View, do the following:

1.Make sure that power to all the devices (Master View Pros and PCs) you will be connecting up, including all pre-existing devices on the installation, have been turned off.

2.Make sure that DIP Switches 1 - 5 of the First Station Master View Pro are all set to the ON position to set it up as a First Station unit (see the table on p. 23 for Dip Switch Station Setting details).

3.Set DIP Switches 1 - 5 of the of the Second (Third, Fourth, etc.), Station Master View Pro according to the table provided on page 23.

CS-1004 / CS-1008 / CS-1016 User Manual

7

2001-01-13

Image 11
Contents CS-1004 /CS-1008 /CS-1016 2001-01-13 Packing List Contents Model Computer Ports Maximum via Daisy Chain OverviewFeatures Cables Connector Type CS Custom CableHardware Requirements ConsoleCS-1016 Front View Power SwitchK/M Reset Port Selection SwitchesPower LED UnpackingCS-1016 Rear View First Stage Installation InstallationPattern Indication Turn on the power to the Master ViewDaisy Chaining PS/2 Mouse Hot Plugging CPU Ports Powering Off and RestartingOperation Hot PluggingOSD Port SelectionManual Hot KeyNumbering Rules Port ID NumberingNumber of Digits Meaning Port Numbering TablePort Numbering is summarized in the following table Hotkey Port Selection Hot Key OperationCtrl + Alt + 1 + Enter to initiate the keyboard broadcast Previous/Next SwitchingHot Key Broadcasting Navigation OSD OperationHeading Explanation OSD Main Menu HeadingsFunction Keys F1 GoToChoice Meaning F2 ScanF3 List F5 Name F4 QVF6 Set Settings are explained in the table belowSetting Function Setting Default Factory Default SettingsFactory default settings are as follows Which case you must start again from the beginning OSD Security FeaturesPassword Lock/Unlock Console Station AppendixStation Numbering Table Symptom Possible Cause Action TroubleshootingFunction CS-1004 CS-1008 CS-1016 SpecificationsFederal Communications Commission Statement Limited Warranty