AMX IR instruction manual Wiring and Installation, Setting the Receive Frequency

Page 11

Wiring and Installation

Wiring and Installation

Before installing the sensors and receivers, set the receive frequency on the units. On the receivers, the AXD-IR+ and AXR-IRSM+, also set the AXlink device number and IR validation level.

To access the jumper pins or switches on the circuit board assembly in the swivel mount units, separate the housing from the swivel base (see FIG. 8).

Swivel mount base

Housing

Circuit board assembly

FIG. 8 Separating the housing from the swivel base on the swivel mount units

On the UniMount units, the AXlink jumpers and switches are on the back of the panel.

Setting the Receive Frequency

Perform the following steps (see FIG. 9) to set the receive frequency:

Sensor circuit board assembly

Receive frequency jumper pins

Receiver circuit board assembly

FIG. 9 Receive frequency jumper pins set at the default setting for receiving 38 kHz

1.Use the set of jumper pins (one set on the sensors and two sets on the receivers-see FIG. 9) on the corner of the circuit boards to set the receive frequency. FIG. 10 illustrates the positioning of the jumpers.

The unit will not operate with one set of pins set for 38 kHz and the other set of pins set for 455 kHz.

IR Sensors and Receivers

7

 

 

 

 

Image 11
Contents IR Sensors Receivers AMX Limited Warranty and Disclaimer Table of Contents Table of Contents Product Information FeaturesAXD-IR+ Specifications Specifications Sensors and ReceiversIRX-DM+ Specifications AXR-IRSM+ SpecificationsApplications IRX-SM+ SpecificationsAXR-IRSM+ Product Information Setting the Receive Frequency Wiring and InstallationSetting the AXlink Device Number Configuring the ReceiversSensor IR validation level Setting the IR Validation LevelReceiver IR validation level Wiring guidelines Wiring the IR Sensors and ReceiversPreparing captive wires Wiring the AXD-IR+ or the AXR-IRSM+ to AXlink Connecting the WiringWiring Specifications Checking AXlink status Wiring the IRX-DM+ or IRX-SM+ to the AMX IR ReceiverChecking IR Data status Mounting the UniMount Sensor or Receiver AXD-IR+ and IRX-DM+ 1-gang cutout dimensionsMounting the Swivel-Mount Sensor or Receiver Installation method aInstallation Method a Installation method BWiring and Installation Wiring and Installation IR Sensors and Receivers AMX reserves