Wiring and Installation

If the LED is on and not flashing, disconnect the AXlink connector and recheck all AXlink connections. Afterward, reconnect the AXlink connector to the panel and verify the LED is flashing once per second.

Mounting the UniMount Sensor or Receiver

FIG. 18 gives cutout dimensions for the AXD-IR+ and IRX-DM+. To install the AXD-IR+ or IRX- DM+, complete the following steps.

1.For wall or podium mounting, AMX recommends mounting the AXD-IR+ or IRX-DM+ in a standard 1-gang wallbox with a minimum internal clearance of

1 3/4" (W) x 2 5/8" (H) x 1 5/8" (D).

INSTALL UNIT USING SUPPLIED #6-32

MACHINE SCREWS AT THESE LOCATIONS

Wall plate

Bezel

FIG. 18 AXD-IR+ and IRX-DM+ 1-gang cutout dimensions

2.Gently remove the bezel from the wallplate.

3.Place the panel in the wallbox and align the screw holes with the mounting holes on the panel.

4.If you are installing the IRX-DM+, remove the housing and wire the unit to the AMX IR receiver as shown in Wiring.

5.If you are installing the AXD-IR+, turn the unit over and locate the AXlink connector.

a.Connect the unit to AXlink data/power bus. See Wiring.

b.Check the AXlink LED. (LED should blink once per second.)

6.Fasten the panel to the wallbox using the screws supplied with the panel.

7.Snap the wallplate back on the bezel.

IR Sensors and Receivers

13

 

 

 

 

Image 17
Contents IR Sensors Receivers AMX Limited Warranty and Disclaimer Table of Contents Table of Contents Product Information FeaturesAXD-IR+ Specifications Specifications Sensors and ReceiversIRX-DM+ Specifications AXR-IRSM+ SpecificationsApplications IRX-SM+ SpecificationsAXR-IRSM+ Product Information Setting the Receive Frequency Wiring and InstallationSetting the AXlink Device Number Configuring the ReceiversSensor IR validation level Setting the IR Validation LevelReceiver IR validation level Wiring guidelines Wiring the IR Sensors and ReceiversPreparing captive wires Wiring the AXD-IR+ or the AXR-IRSM+ to AXlink Connecting the WiringWiring Specifications Checking AXlink status Wiring the IRX-DM+ or IRX-SM+ to the AMX IR ReceiverChecking IR Data status Mounting the UniMount Sensor or Receiver AXD-IR+ and IRX-DM+ 1-gang cutout dimensionsMounting the Swivel-Mount Sensor or Receiver Installation method aInstallation Method a Installation method BWiring and Installation Wiring and Installation IR Sensors and Receivers AMX reserves