AMX Wiring the IR Sensors and Receivers, Preparing captive wires, Wiring guidelines

Page 14

Wiring and Installation

Wiring the IR Sensors and Receivers

The IR Sensors and Receivers use a four-pin AXlink connector for power and data. If the distance between the panel and Central Controller exceeds power consumption limits, you can connect a local 12 VDC power supply to the AXlink connector.

FIG. 14 shows the location of the AXlink connector on the rear panel of the IR sensors and receivers.

Sensor circuit board assembly

AXlink connector

Receiver circuit board assembly

FIG. 14 Circuit board assemblies for IR sensors and receivers

To access the AXlink connector on the AXR-IRSM+, separate the swivel-mount base from the housing. (Refer to Figure 4.) On the AXD-IR+, the AXlink connector is on the underside of the unit.

Preparing captive wires

You will need a wire stripper and a flat-blade screwdriver to prepare the captive wires.

Prepare and connect the captive wires as follows.

1.Strip .25 inch (6.35 mm) of wire insulation off all wires.

2.Insert each wire into the appropriate opening on the connector according to the wiring diagrams (following) in this section.

3.Turn the flat-head screws clockwise to secure the wire in the connector.

Do not over-torque the screw. Doing so can bend the seating pin

Wiring guidelines

The IR sensor or receiver requires 12 VDC power to operate properly. The power is supplied by the AMX system's AXlink cable. The maximum wiring distance between the Central Controller and the receiver or sensor is determined by power consumption, supplied voltage, and the wire gauge used for the cable. The following table lists wire sizes and the maximum lengths allowable between

 

10

IR Sensors and Receivers

 

 

 

Image 14
Contents IR Sensors Receivers AMX Limited Warranty and Disclaimer Table of Contents Table of Contents Features Product InformationSpecifications Sensors and Receivers AXD-IR+ SpecificationsAXR-IRSM+ Specifications IRX-DM+ SpecificationsIRX-SM+ Specifications ApplicationsAXR-IRSM+ Product Information Wiring and Installation Setting the Receive FrequencyConfiguring the Receivers Setting the AXlink Device NumberSensor IR validation level Setting the IR Validation LevelReceiver IR validation level Wiring guidelines Wiring the IR Sensors and ReceiversPreparing captive wires Wiring the AXD-IR+ or the AXR-IRSM+ to AXlink Connecting the WiringWiring Specifications Checking AXlink status Wiring the IRX-DM+ or IRX-SM+ to the AMX IR ReceiverChecking IR Data status AXD-IR+ and IRX-DM+ 1-gang cutout dimensions Mounting the UniMount Sensor or ReceiverInstallation method a Mounting the Swivel-Mount Sensor or ReceiverInstallation method B Installation Method aWiring and Installation Wiring and Installation IR Sensors and Receivers AMX reserves