Multigang Installations
In multigang installations, several controls are grouped hori- zontally in one multigang wallbox.
•No derating is required for Remotes.
•When ganging Remotes with dimmers or switches in the same wallbox, derating is required for the dimmers or switches. See the installation instructions that came with the dimmer or switch for derating requirements.
Note: Controls do not have fins that need to be removed for multigang installations.
Installation
Danger - Locate and remove fuse or lock circuit breaker in the OFF position before proceeding. Wiring with power ON may result in personal injury.
Short Circuit Check: Check the installation for short cir- cuits before installing control(s). With power OFF, install standard mechanical switch(es) between Hot and load.
Restore power. If lights do not work or a breaker trips, check wiring. Correct wiring and check again. Install con- trol(s) only when short is no longer present. Warranty is void if control is turned ON with a shorted circuit.
1.Turn power OFF at fusebox or circuit breaker.
2.Prepare wires. When making wire connections, follow the recommended strip lengths and combinations for the supplied wire connectors. Note: Wire connectors provid- ed are suitable for copper wire only.
Large:
Strip insulation 1/2" (13mm) for #10 AWG (6mm2), #12 AWG (4mm2) or #14 AWG (2.5mm2).
Strip insulation 5/8" (16mm) for #16 AWG (1.5mm2) or #18 AWG (1.0mm2).
Use to join one or two #12 or 14 AWG sup-
5.Attach Lutron Claro® or Satin ColorsTM wallplate adapter and wallplate.
a.Loosely install control mounting screws.
b.Tighten wallplate adapter mounting screws snug.
c.Tighten control mounting screws until wallplate adapter is flush to wall (do not
d.Snap wallplate onto wallplate adapter, and verify that control is not submerged.
e.If control is submerged, loosen mounting screws appropriately.
6.Complete wiring for all dimmers, switches and remotes in this circuit.
7.Restore power. Check for correct local operation (see Local Operation, page 5).
Mounting Diagram
Wallplate
Control Adapter
Mounting Mounting
Screws Screws
ply wires with one #10, 12, 14, 16 or 18 AWG control wire.
Large
Wallbox
3.Wire controls using Wiring Diagrams 1 and 2 (page 3). When using power boosters or interfaces, use Wiring Diagrams 3, 4, and 5 (page 4). Up to nine
4.Push all wires back into the wallbox and loosely fasten the control to the wallbox using the control mounting screws provided. Do not pinch the wires.
Control
Included:
Wire Connectors (4)
Wallplate/Adapter purchased separately.
Mounting Screws (2)
2